Specifications
22
Parts and Accessories
Description Dacor Part Number
Dacor Stainless Steel Cleaner A302
Package of pickup tubes (package of 10) AWSPT
Silicon spray, food grade AWSSS
Bottle sizing tool AWSSZ
Clean-Pour dispensing head gaskets (package of 20) AWSCPG20
Regulator assembly (includes hose assembly and quick connect fitting) AWSHXR
Argon gas canister - 17L (package of 3)* AWSAGC
Dispensing head, mixed (package of 4) AWSCPM
Dispensing head with green gasket AWSCPG
Dispensing head with red gasket AWSCPR
Dispensing head with white gasket AWSCPW
Drip cloth AWSDC
Drip tray AWSDT
Two zone temperature kit AWSDZ
*Each 17 L disposable tank of argon gas provides preservation and dispensing for approximately 20 bottles
of wine.
To order parts and accessories, contact your Dacor dealer or visit www.everythingdacor.com.
Before You Call for Service
Problem Solution Guide
Problem May Be Caused By What to Do
Nothing works, display is
dark.
Power switch is off. Make sure main power switch is in ON
position See page 8 for location. Slide
all the way up.
System not connected to electri-
cal power.
Check to make sure power plug is con-
nected to electrical outlet and to power
supply on back of unit. Also make sure
cable from back of power supply to con-
nector on back of unit is connected. See
page 8 for location.
Power to electrical outlet is off. Turn on power at circuit breaker or fuse
box for electrical outlet. Check for tripped
breaker or blown fuse.
Power outage. Contact power company.
Nothing works, display is
lit.
Power switch is set to service
mode.
Slide power switch to ON position. See
page 8.
See also “Empty Bottle Message”
on facing page.
One or more red lights
flashing.
Low gas pressure detected. Although system may continue to work,
gas cylinder needs to be replaced as soon
as possible.