Installation guide

INSTALLATION
INSTRUCTIONS
TURNING
OFF
THE
PoweER
SUPPLY
Before
attempting
to
connect
the
appliance
to
power,
turn
off
the
electrical
power
supply.
Also,
always
turn
off
electrical
power
to
the
appliance
prior
to
servicing
it.
WARNING
WARNING
-
Failure
to
disconnect
power
may
result
in
electrical
shock
or
fire
hazard.
ELECTRICAL
CONNECTION
WARNING
This
appliance
must
be
connected
to
a
grounded,
metallic,
permanent
wiring
system.
Alternatively,
a
grounding
conductor
should
be
connected
fo
the
grounding
terminal
or
lead
on
the
appliance.
Failure
to
do
so
may
result
in
an
electrical
shock
hazard.
Do
not
install
a
fuse
in
the
neutral
or
ground
circuit.
A
fuse
in
the
neutral
of
ground
circuit
may
result
in
an
electrical
shock
hazard.
GROUNDING
INSTRUCTIONS
The
appliance must
be
connected
to
the
power
supply
with
copper
wire
only.
The
use
of
aluminum
wire
may
result
in
unsatisfactory
connections.
Flexible
armored
or
non-metallic,
sheathed
copper
cable
(with
grounding
wire)
should
be
used
to
connect
the
appliance
to
the
junction
box.
A
UL-listed
connector
must
be
used
to
directly
connect
the
cable
to
the
junction
box.
Be
certain
to
locate
the
junction
box
such
that
the
electrical
supply
may
be
easily
disconnected
in
the
event
that
service
becomes
necessary.
Also,
provide
extra
slack
in
the
cable
to
allow
the
oven
to
slide
forward
for
servicing.
This
appliance
must
be
electrically
grounded.
With
the
oven
positioned
directly
in
front
of
the
cabinet
cutout,
feed
the
appliance
conduit
to
the
electrical
junction
box.
Then,
depending
upon
local
codes,
utilize
one
of
the
following
techniques
to
connect
the
appliance
to
the
electrical
power
supply:
A.
Connecting
to
a
Four-Wire
Electrical
System
1.
Separate
the
green
and
white
appliance
wires.
2.
Connect
the
white
appliance
wire
to
the
neutral
(white)
supply
wire
in
the
junction
box.
3.
Connect
the
black
appliance
wire
to
the
black
(L1)
power
supply
wire
in
the
junction
box.
4.
Connect
the
red
appliance
wire
to
the
red
(L2)
power
supply
wire
in
the
junction
box.
5.
Connect
the
green
appliance
wire
to
the
green
house grounding
wire
Cable
from
power
supply
Junction
-_—”
WHITE
RED
7}
WHITE
GREEN
|)
GREEN
|
BLACK
_L
BLACK
Wire
nut
(4
places)
Conduit
from
appliance
Connecting
the
Appliance
to
a
Four-Wire
Power
Supply
WARNING
WARNING
Do
not
connect
the
green
appliance
wire
to
the
neutral
(white)
junction
box
wire
unless
local
building
codes
permit.
Cable
from
power
supply
Junction
aol
RED
GREEN
RED
WHITE
WHITE
BLACK
1
BLACK
wy
Wire
nut
(3
places)
Conduit
from
appliance
Connecting
the
Appliance
Ground
to
Supply
Neutral
B.
Connecting
the
Green
Appliance
Wire
to
the
Neutral
(White)
Supply
Wire
Where
Local
Codes
Permit
Connect
the
green
and
white
appliance
wires
to
the
neutral (white)
supply
wire
in
the
junction
box.
Connect
the
black
appliance
wire
to
the
black
(L1)
power
supply
wire
in
the
junction
box.
Connect
the red
appliance
wire
to
the
black
(L2)
power
supply
wire
in
the
junction
box.
dacor