Installation Instructions Epicure®Wall Mount Range Hood with Remote Blower For use with models: EHR30, EHR36, EHR42, EHR48, EHR54 APPROVED FOR USE WITH ALL DACOR ® RANGES AND TESTED IN ACCORDANCE WITH THE LATEST EDITION STANDARD FOR ELECTRIC FANS AND CAN/CSA-C22.2 FOR FANS AND VENTILATORS. PartNo. 103781 Rev. D COOKTOPS. OF ANSI/UL 507 NO.
Important Safety Instructions .......................................... Important Information About Safety Instructions .............. General Safety Precautions ............................................. Product Specifications .................................................... General Specifications ..................................................... Dimensions ...................................................................... Product Specifications .............................................
Important Information About Safety Instructions Safety Symbols and Labels [] The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. • DANGER Immediate hazards that WILL resu t n severe pers0n a injury or death ...........................
I [_ CAUTION Forgenera Vent atng UseOn y.Do notuse toexhausthazardous or exp Os ve matera sand Vaporsl General Safety Precautions To reduce the risk of fire, electric shock, serious precautions, including the following: injury or death when using your appliance, follow basic safety WARNING • Do not. install or operate this hood if it has been damaged, dropped, has damaged electrical wires or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
General Specifications All Models Fan Speeds Filters Exhaust(s) Weight Specifications 4 Mesh type, dishwasher safe 8-inch Total Connect Load 120 Vac, 60 Hz, 6.5Amp. Lights Max. 120 Vac, 75 W halogen Model Specific Model Number Lights Filters Exhaust Outputs EHR48 EHR54 EHR42 EHR30 EHR36 3 2 2 4 3 2 2 1 Model Weight EHR3012 39 Ibs. (18 kg) EHR3018, EHR3612 44 Ibs. (20 kg) EHR3618 48 Ibs. (22 kg) EHR4212 46 Ibs. (21 kg) EHR4218 51 Ibs. (23 kg) EHR4812 52 Ibs.
Dimensions Tolerances: +1/16",-0 (1.6 mm,-0), unless otherwise stated. NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood. Dual exhaust models* Standard 8" duct connection Single exhaust models** Standard 8" duct connection M Electrical access holes 7/8" Dia. (5.1 cm) _ ,I" [ % / _" \ I ! + \ II / I \ I! + + I \ \ I I I / I \ S l Front of hood 6 1/8" (15.6 cm) / % S II f _-- 9 7/8" "-_ (25.1 cm) 1 ½" (3.
OVERALL 11 (30.2 cm) Model A EHR3012 29 7/8" (75.9 cm) EHR3612 DIMENSIONS B C D_ 35 7/8" (91.1 cm) 26 7/8" 12 3/8" 4 1/2" EHR4212 41 7/8" (106.4 cm) (68.3 cm) (31.4 cm) (11.4 cm) EHR4812 47 7/8" (121.6 cm) EHR4218 41 7/8" (106.4 cm) EHR3018 29 7/8" (75.9 cm) EHR3618 35 7/8" (91.1 cm) EHR4818 26 7/8" (68.3 cm) 18" (45.7 cm) 6 1/8" (15.6 cm) 47 7/8" (121.6 cm) EHR5418 53 7/8 (136.8 cm) *** See diagram on facing page. Overall Dimensions (5.1 cm) (34.9 cm) 32" (81.
[_ WARNING I observe all g0verning c0des and ordinances during planning and installationl Contact y0ur local building department further informati0nl Cabinet Layout [_ [_ for I I IMPORTANT See the diagram for minimum installed distance from the hood t0 the co0ktop surfacel The minimum specified distance maybe higher for the particular range or cooktop in use: Check the manufacturers specifications for the €ooktop or rangel WARNING To reduce the risk of personal injury caused by reaching over a hot
[_ • The customer must supply conduit with minimum current carrying capacity of 8 Amps to supply power to the remote blower from the hood. WARNING To prevent combustion by-products, smoke or odors from entering the home and to improve efficiency, tape all duct joints securely. • Use only duct work deemed acceptable by state, municipal and local codes. • Range hoods may interrupt the proper flow of smoke and combustion gases from furnaces, gas water heaters and fireplaces.
Keep turns as far away from the hood exhaust as possible, and as much space between bends as possible. Duct Work Equivalent Lengths EQUIVALENT LENGTHS Piece Subtract Piece Subtract 8" 90° elbow 7 feet 10" 90° elbow 5 feet 8" 45° elbow 3 feet 10" 45° elbow 2 feet 3¼" X 10" to round 90° transition 25 feet 3¼" X 10"to 8'710" round transition 4 feet Roof cap , Walt cap with damper , For best performance, use round duct instead of rectangular, especially when elbows are required.
Electrical Service Installation Back wall WARNING The e!ectric service to the range hood sh0u only by a licensed electrician. ................. I nsta e d Install a junction box in the vicinity of the hood electrical access holes according to local codes. Install it either behind or above the hood. The diagram below shows suggested locations. Drill 7/8" holes in the wall or cabinet as necessary to allow the wiring to pass through into the hood. See page 4 for hole locations.
. WARNING Do not install the range hood unless the electrical service provided meets the range hood specifications. . Using the existing screws, attach the cover plate removed in step 5 to the top of the hood to cover the hole. Attach the duct collar(s) removed in step 2 to the back of the unit using the existing screws. Observe all governing codes and ordinances during installation. Contact your local building department for further information.
Installing the AHT1 0 Transition" 12" high models with rear exhaust: Top exhaust models and 18" Center the transition over the duct collars while resting the unmodified edge on the top of the hood. Fasten in place using sheet metal screws (not included). Seal the base of of the transition with duct tape. high models with rear exhaust: Center the transition over the duct collars and fasten it in place using sheet metal screws (not included).
Hanging the Range Hood [_ Reattach the hood to the temporary mounting brackets. Lift the hood into its final position and fasten it in place. back of the through hood intothe themounting studs, mounting Insert and the top fasteners slots in the WARNING Hanging the range hood requires _o people: Do not attempt to lift the hood Without assistance: 1. Remove the plastic coating from the outside of the hood. 2. Remove the filter(s) to reduce weight and avoid damage. 3. 7 8.
6. Connect the wiring to the remote/in-line blower and the power supply line from the junction box as shown. _E_ Hot To remote/ in-line blower Neutral Ground _ .-_ To junction box , Connect the hood wiring to an electrical junction box on a dedicated circuit. See page 6 for specifications. Connect it according to the 3-Wire Connection to Junction Box method shown or External Ground Method shown on the following page.
To house circuit breaker panel or fuse box Separate No. 10 (minimum) / copper ground wire I Wire Nut, 3 places Meter WHITE WHITE _[_ No. 4 copper wire GREEN GREEN _ UL/CSA approved NEMA strain relief Junction Box \ Insulated Pipe Jumper (if necessary) To range hood WARNING • i Do not ground the circuit to a gas linel Do not ground the circuit to a hot water pipe. water lines that are insulated must be jumped t0 assure continuity to ground: See above.
Verifying Proper Operation Installation Checklist WARNING /_ _" Feature Keys _ 'X_ Main • To ensure a safe and proper installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked. • Proper installation is the responsibility of the homeowner. The importance of proper installation of your Dacor range hood cannot be overemphasized.
_ i " ' I o I"1'1 -r II I"1'1 -r _o o_z m o II o I"1'1 -r C z_ OG0 :',I.__:__ . __.'.'__1 m ;;0 '' m 0 0 ITI 16 cl_car o m o 0 I-0 '.
r7 rY < 0 re w a 0 0 nO z 0 o LU n- I_J m-I_ z .
4# The Life of the Kitchen? Dacor • 1440 Bridge Gate Drive, Diamond Bar, CA 91765 • Tel: (800) 793-0093 • FAX: (626) 403-3130 • www.Dacor.