Installation guide

Planning
the
Installation
Electrical
Specifications
IMPORTANT
«Preheat
times
and
cavity
temperature
recovery
times
will
be
increased.
slightly
if-operating
on
less-than.a
240
Vac
circuit.
«This
appliance
is.provided
with
electrical:connection
leads
in
a
flexible
metal
conduit.
These
leads
may
be
a
-smaller.gage
than
the
standard
household
wiring
of
the
dedicated
supply.
circuit,
but
they
are
suitable
for
connection
to
these
circuits-under.the
jurisdiction
of
the.
National
Electric
Code,
and/or
the
local
inspection
authority.
°--Locate
the
junction
box’so
that
the
wiring
may
be
dis-
connected-without
removing
the
oven
from
the
wall.
it
is
the
owner’s
responsibility
to
ensure
that
a
qualified
electrician
performs
the
electrical
connection
of
this
appli-
ance.
The
electrical
installation,
including
minimum
supply
wire
size,
must
comply
with
the
National
Electric
Code
ANSI/NFPA
70
(latest
revision)
and
local
codes
and
ordi-
nances.
A
copy
of
this
standard
may
be
obtained
from:
National
Fire
Protection
Association
1
Batterymarch
Park
Quincy,
Massachusetts
02269-9101
The
correct
voltage,
frequency
and
amperage
must
be
sup-
plied
to
the
appliance
from
a
dedicated,
grounded,
single
phase
circuit
that
is
protected
by
a
properly
sized
circuit
breaker
or
time-delay
fuse.
If
a
time-delay
fuse
is
utilized,
fuse
both
sides
of
the
line
(L1
and
L2).
Model
Type
Dedicated
Circuit
Total
yp
Requirements
Connected
Load
Single
27”
240
Vac
60
Hz.,
4
wire*,
30
Amp.
4.6
kW
(19.5
Amp.)
Single
30”
dedicated
Double
27”
240
Vac
60
Hz.,
4
wire*,
50
Amp.
|
9.25
kW
(38.9
Amp.)
Double
30”
dedicated
*
Two
120
Vac
hot
(L1
and
L2),
one
neutral,
one
ground.
The
above
electrical
ratings
are
for
reference
only.
For
the
exact
ratings
see
the
product
data
plate.
See
page
3
for
location.
Installation
Instructions
Parts
List
Verify
that
all
the
parts
are
included.
If
any
item
is
missing
or
damaged,
please
contact
your
dealer
immediately.
Also
make
certain
that
you
have
ail
tools
and
parts
necessary
to
ensure
a
proper
installation
before
proceeding.
*
Exhaust
deflector
9
27”
defector
-
PN
46050B
or
&
30°
deflector
-
PN
46051B
*
Mounting
and
exhaust
deflector
screw
kit
®
Single
oven
screw
kit
-
four
(4)
3/4”
mounting
screws,
four
(4)
1
1/4”
mounting
screws
and
three
(3)
exhaust
deflector
screws
-
PN
700486-1
or
®
Double
oven
screw
kit
-
Six
(6)
3/4”
mounting
screws,
six
(6)
1
1/4”
mounting
screws
and
three
(3)
exhaust
deflector
screws
-
PN
700486-2
*
Meat
probe,
one
(1)
-
PN
72723
*
Broiler
grill
and
pan
-
PN
12157
*
Standard
oven
racks
two
(2)
for
a
single
oven,
five
(5)
for
a
double
oven
®
27”
standard
rack
-
PN
72747
or
®
30°
standard
rack
-
PN
72713
*
GlideRack™
oven
rack,
one
(1)
®
27”
GlideRack™
oven
rack
-
PN
72948
or
®
30”
GlideRack™
oven
rack
-
PN
72949
*
Stainless
steel
cleaner
-
stainless
steel
models
only
PN
A302
*
Product
literature
dacor
9