Specifications

Selecting the Location
Carefully check the location where the oven is to be
installed. The oven should be placed for convenient
access, but away from drafts that may be caused by
doors, windows, and heating, ventilation and air condi-
tioning outlets.
* Make certain that electrical power can be provided in
the selected location. Be certain that proper clearance
is provided for the oven door when it is in the open
position.
Cabinet Cutout
Plan the installation so that all minimum clearances are
met or exceeded. Cutout dimensions shown provide
minimum clearances, unless otherwise noted.
The specified minimum cabinet depth and width must
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
Model
Number
EO127
MOH127
MOV127
EO130
MOH130
MOV130
EO227
MOH227
MOV227
EO230
MOH230
MOV230
A B C
27" 7/16"
(69.7 cm)
50 9/16"
(128.4 cm)
25 ½"
(64.8 cm)
28 ½"
(72.4 cm)
25 ½"
(64.8 cm)
27"
(68.6 cm)
30"
(76.2 cm)
27"
(68.6 cm)
28 ½" 30"
(72.4 cm) (76.2 cm)
56 ½"
(143.5 cm)
62 ½"
(158.8 cm)
NA
* Cabinet cutout dimensions must be used as indicated.
Cutout tolerances: +1/16 (1.6 mm), -0, unless otherwise stated.
t
1" (2.5 cm)
min. clear to
bottom
of door
t
1 3A"(4.5 cm) min.
clear to top of
door for heat
exhaust
C
®
Recommended
electrical
location
/
/
/
/
A
I
/
/
/
Single Wall
Oven Cutout
_/4" (1.9 cm)
Alternate
- - " electrical
location
support platform //
®
31 1/4" (79.4 cm)
recommended
(may be altered)
4" typical toe kick (shown)
1" (2.5 cm) min.
clear to
bottom of
door
13A"(4.5 cm) min.
clear to top of
door for heat
exhaust
t
_ C
o
m
Recommended
electrical
location
/
/
Double Wall
Oven Cutout
A
4 I
a
A
/
/
/
u' .
4" typical toe kick (shown)
3/4" (1.9 cm)
support platform
9 5/8" (24.4 cm)
recommended
(may be altered)
t
6 _SCD_