Installation guide

Installation
Instructions
Connecting
to
a
Three
(3)
Wire
Electrical
System
with
External
Ground
-
Where
Local
Connecting
to
a
Three
(3)
Wire
Electrical
System
-
Where
Local
Codes
Permit
WARNING
Codes
Permit
Do
not
connect
the
green
appliance
conduit
wire
to
the
neutral
(white)
junction box wire-unless-
local
building
codes
permit.
WARNING
Do-not
connect
the
green
appliance
wire
to.
the
junc-
tion
box
or
to.a
cold
water
pipe
unless
local
building
Separate
the
wires
coming
out
of
the
appliance
conduit.
Connect
the
green
and
white wires
from
the
appliance
conduit
to
the
white
(neutral)
supply
wire
in
the
junction
box.
Connect
the
black
wire
from
the
appliance
conduit
to
the
black
(L1)
supply
wire
in
the
junction
box.
Connect
the red
wire
from
the
appliance
conduit
to
the
red
(L2)
supply
wire
in
the
junction
box.
Cable
from
circuit
breaker
panel
or
fuse
box
Junction
box
GREEN
WHITE
\
WHITE
/
BLACK
|
.
BLACK
_
\
RED
r
RED
CI
\
Wire
nut
(3
places)
| |
Conduit
to
wall
oven
Three
(3)
Wire
Junction
Box
Connection
-
(Where
Local
Codes
Permit)
codes
permit.
«Do
not
ground-the
appliance
to.a
gas
supply
pipe
or
hot
water.
pipe,
«~1f
connecting
the
ground
wire
to.a
grounded.
cold
water
pipe,
connect-using
a
separate
copper
grounding
wire
(No.-10:minimum)
and
a
clamp
with
an
external
grounding
screw.
The
grounded-cold
water
pipe
must
have
metal
continuity
to
electrical
ground
and:
must
not
be
interrupted
by
insulating
materials:
Any
insulating
materials
must
be
jumped,
with:a
minimum,
4.
AWG
wire
to-establish
continuity
to
ground.
No.
4
copper
Meter
wire
|
Metal
water
Bare
metal
insulated
Pipe
Jumper
NOTE
lithe
junction
.box-has
been
properly
grounded
by
a
licensed
electrician,
the
green
(ground)
wire
from
the
appliance
conduit
may-be
connected
to
the
junction
box
using
a
loop
terminal.
See
the
diagram
on
the
following
page.
To
connect
the
green
appliance
conduit
wire
to
a
grounded
cold
water
pipe:
1.
Separate
the
wires
coming
out
of
the
appliance
conduit.
2.
Connect
the
white
wire
from
the
appliance
conduit
to
the
white
(neutral)
supply
wire
in
the
junction
box.
3.
Connect
the
black
wire
from
the
appliance
conduit
to
the
black
(L1)
supply
wire
in
the
junction
box.
4.
Connect
the red
wire
from
the
appliance
conduit
to
the
red
(L2)
supply
wire
in
the
junction
box.
5.
Connect
the
green
wire
from
the
appliance
conduit
to
a
grounded
cold
water
pipe
as
shown.
Jumper
any
insulating
materials
as
shown
above
with
a
length
of
No.
4
copper
wire.
Securely
clamp
the
wire
to
bare
metal
at
both
ends.
dacor
11