Installation Instructions Downdraft Raised Vent Models: ERV30, ERV36, ERV48 PRV30, PRV36, PRV46 Use these downdraft raised vents only with approved Dacor ® appliances. See the installation instructions for the particular appliance model being installed to determine suitability. Part No. 65335 Rev.
Table of Contents Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 1 Safety Symbols and Labels.............................................. 1 General Safety Precautions.............................................. 2 Product Specifications...................................................... 3 Product Dimensions.......................................................... 3 Installation Specifications....................
Important Safety Instructions Safety Symbols and Labels Important Information About Safety Instructions • • DANGER The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Immediate hazards that WILL result in severe personal injury or death.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following: Warning • Do not install or operate a damaged appliance. If you receive a damaged appliance, contact your dealer or builder. • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
Product Specifications Product Dimensions Tolerances: ±1/16” (±1.
Installation Specifications Electrical Specifications warning • The customer must supply 3 conductor wiring/conduit with minimum current carrying capacity of 8 Amps. to supply power to the remote or in-line blower from the raised vent. See General System Layout and Planning the Duct Work for further details. • It is the owner’s responsibility to ensure that electrical outlet is installed by a licensed electrician.
Installation Specifications Backsplash Backsplash Countertop overhang Countertop overhang Vertical non-combustible surface rear wall Vertical non-combustible surface rear wall Notches required for some rasied vent installations, see cooktop installation instructions Notches required for some raised vent installations, see range installation instructions See the cooktop installation instructions for exact countertop and cabinet dimensions Notches for self-rimming style installations, see range insta
Installation Specifications Planning the Duct Work warning • To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages. • Tape all duct joints securely to prevent combustion by-products, smoke or odors from entering the home. Doing so will also improve system efficiency. • TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.
Installation Specifications • On side exhaust installations, allow five inches of space on the side for the ADT2 exhaust transition plus additional space for the duct attached to it (X). • Make sure duct work does not interfere with floor joists or wall studs. • With concrete slab construction, “box-in” the duct work and blower wiring to prevent collapsing or other damage when the wet concrete is poured.
Installation Instructions Installation Preparation 2. Cut and remove the foil material inside the knock-out hole. If you fail to remove the foil, the vent will not work. Verify Package Contents 3.
Installation Instructions 5. Gently slide the vent into the rear of the countertop cutout with the electrical access panel toward the front. Installing the Blower and Ducts 1. Install the remote or in-line blower according to the blower installation instructions. Top of vent resting on countertop Anchor leg Put nuts/ washers on studs 2. Install the duct work according to the Installation Specifications section. Use sheet metal screws and duct tape to connect and seal all of the pieces.
Installation Instructions 1. Run the wiring/conduit line used to supply power from the raised vent to the blower parallel to the duct work. Electrical Installation warning • ELECTRIC SHOCK HAZARD - Do not connect the raised vent power plug to the electrical outlet until installation is complete. • Failure to complete electrical connections properly may result in an electric shock hazard or a damaged or non-functional system. Follow the wiring diagrams carefully to ensure a proper installation.
Installation Instructions REMP16 remote blower Connect wires/conduit according to remote blower installation instructions Raised vent Range See Raised Vent Electrical Access Panel on facing page Floor Wiring/conduit from raised vent to remote blower Example of Installation with Bottom Exhaust (Side View) Range/Cooktop Installation Install the range or cooktop according to its installation instructions.
Installation Instructions Verifying Proper Operation warning • Read the raised vent use and care manual completely before operation. • Install all of the front filters prior to operating the raised vent. Refer to the use and care manual for filter installation instructions. caution To prevent damage to the raised vent power cord, route it away from the surfaces of the range or cooktop before connecting it. 1. Make sure the power switch on the top of the raised vent is in the up position.
Wiring Diagram UP LIMIT SWITCH DOWN LIMIT SWITCH SNORKEL SWITCH COM COM COM NO NC NC NO RED RED BLUE BLK YEL NO NC CHASSIS GROUND STUD YEL WHT REMOTE POT RELAY N L SPEED CONTROL BLK ORNG BLUE WHT WHT ORNG COM RED NO L2 N2 BLOWER OUTPUT L1 N1 GND GND POWER INPUT GROUND BLK 13