Product specifications

9
5. Gently slide the vent into the rear of the countertop cut-
out with the electrical access panel toward the front.
6. Loosely attach the anchoring legs to the studs on the
left and right sides of the raised vent using the provided
keps nuts and washers.
7. Adjust the anchoring leg height so that the end caps
are gently resting on the counter, then tighten the hex
nuts.
8. Secure the anchoring legs to the cabinet floor with the
provided wood screws.
Installation Instructions
Put nuts/
washers on
studs
Front of
raised vent
Floor
Top of vent resting
on countertop
Electrical access
panel
Anchor leg
Installing the Blower and Ducts
1. Install the remote or in-line blower according to the
blower installation instructions.
2. Install the duct work according to the Installation
Specifications section. Use sheet metal screws and
duct tape to connect and seal all of the pieces. Support
the duct weight as necessary to ensure sealed joints.
Example of Installation with Rear Exhaust
(Side View)
REMP series
remote blower
Floor
Wall board
Range
Raised vent
configured for rear
exhaust
Raised vent
Backsplash
Duct work between
raised vent and
remote blower
Wiring/conduit that supplies power
to remote blower (see Electrical
Installation, page 10)
3 1/4” X 10”
to 10” round
transition and
45°
adjustable elbow