Troubleshooting guide
Page 9-12
DACOR RANGE SERVICE MANUAL
Stack burner orifice replacement
Use a 7 mm hex driver or socket to remove
the orifice from the burner base. The main
orifice M is located in the center of the
burner
. The simmer orifice N is located near
the outside of the base. Consult the Dacor
technical service department for the correct
orifice size. The size of each orifice is stamped
on its side.
Tighten the replacement orifice into place with
the 7 mm hex tool.
R
epeat the above steps for any other stack
burners that need to be serviced.
Crown Burner
Turn off the gas supply and power to the
range at the junction or fuse box.
Remove the spill trays. See the Removing the
Spill Trays section on page 8-7.
Crown burner igniter replacement
The crown burner igniter is mounted in the
crown burner base. Pry the retainer ring O
at the bottom of the igniter spring P off the
igniter Q .
Slip the igniter wire off and pull the igniter
out of the burner base.
R
eattach the igniter to the base in the reverse
order.
•
•
•
•
•
•
•
•
Cooktop Component Repair (continued)
M
N
Q
P
O
Crown burner orifice replacement
Consult Dacor technical service department for
the correct orifice sizes. The size of each orifice is
stamped on its side.
The main orifice R on the crown burner
is located at the end of the v
enturi tube
assembly S . Use a 7 mm hex wrench to
remo
ve and install the orifice.
•
R
S