Troubleshooting guide

Page 9-13
SECTION 9 - COMPONENT REPAIR
Crown burner orifice replacement
(continued)
The simmer orifice is attached to a fitting on
the side of the crown burner. Remove the
fitting retaining clip T to access the simmer
orifice fitting.
Pull the fitting U out of the side of the
burner
.
Use a 7 mm hex wrench to remove the
simmer orifice V from the fitting.
Tighten the replacement orifice into place with
a 7 mm hex wrench.
R
epeat the above steps for the other crown
burner if it requires service.
Venturi Adjustment
For proper operation, the gap between the end of
the crown burner main orifice R and the end of
the
venturi X needs to be set to 9 mm.
T
o adjust the venturi gap, loosen the
set screw W on the side of the venture
assembly
.
Slide the venturi in and out of the venturi
assembly to adjust the gap.
After Burner Service is Complete:
Reinstall the spill trays.
Reattach the igniter wires to the stack burner
igniters.
Reassemble the cooktop and test it to ensure
that repairs were properly completed.
T
U
V
W
R
X