Specifications
Cabinet Layout (continued)
Non-combustible
rear wall recommeded
/
10" Min.\ 1/4" Min. (6 mm)
(254 mm) _ Countertop
both sides _ o_erhang
_ Combustible side _ ]i_ ' '
wallaboverange I
-_29 1/2" (749 mm)_ I _ I
countertop opening I ""-.I
30" (762 mm)_ ] H J K
cabinet opening I I
below countertop I I
Cabinet face I \ I
below countertop _ _
Notch countertop _1 I
overhang to width of
cabinets Countertop front
Countertop Height: Min: 35 5/8" (905 mm) Max: 37 3/8" (949 mm)
Top View - Model ER30DSR - Counter/Cabinet Cutout
Dimensions for Self-Rimming Installation
Notes For All Self-Rimming Installations:
• On installations without a raised vent (see above), when
sliding the range into position, it will stop when the rear of
the control panel contacts the notches toward the front of the
countertop The range trim will partially cover the overhang in
back
On installations with a raised vent (see above right), install
Dacor trim kit ATK30SR When sliding the range into position,
it will stop when the rear of the control panel contacts the
notches toward the front of the countertop The range trim will
partially cover the front of the raised vent chassis in back
APPROVED RAISED VENT MODELS: Use onlv Dacor model
ERV30 or PRV30.
10" Min.-.. 3/8" Min. (10 mm)
Non-combustible (254 mm) "_ Countertop
rear wall recommended
both sides _ overhang
\
I _27 1/2" (699 mm)_ _ f 2 3/8" (60 mm)
raised vent opening - lift
29 1/2"(749 mm) - I / /
countertopopening 4,_ / /
"_" _30" (762 mm) .J I | |
cabinet opening _ [ H J
_ belowcountertOPbelowcountertop _ _'__ "/llli*
_Combustible side _ I
wall above range _ | I
Cabinet face --. I _ I
__ _ __/___ _ __
. ,. Notchcountertop
overhang to width of
cabinets Countertop front
Countertop Height: Min: 35 5/8" (905 mm) Max: 37 1/4" (946 mm)
Top View - Model ER30DSR - Counter/Cabinet Cutout
Dimensions - Self-Rimming Installation with Raised Vent
ER30DSR with H J K
no side panels no 23 1/2" 23 1/2" 24" to
raised vent (597 mm) (597 mm) 25 9/16"
3-inch side panels* 20 1/2" 20 1/2" to 21" to
and no raised vent (521 mm) 23 1/2" 25 9/16"
no side panels and 24" 24" 24 1/2" to
raised vent (610 mm) (610 mm) 26 1/16"
3-inch side panels 21" 21" to 24" 21 1/2" to
and raised vent (533 mm) 26 1/16"
Optional side panels (PN ARSP3) cover unfinished chassis sides
when the cabinet face is recessed behind back of control panel.
Preparing for Installation
IMPORTANT: Within the Commonwealth of Massachusetts, this
appliance must be installed by a licensed plumber or gas fitter
NOTE: When installing a backguard, always install it before
sliding the range into place See page 9
Unpacking the Range
Unpack the range and verify that all required parts have been
provided If any item is missing or damaged, please contact
your dealer immediately Do not install a damaged or incomplete
appliance The customer must report cosmetic issues within 30
days of installation
8 _SCD_
Parts List
• 2 grates
• 1 small stack burner cap
• 1 small stack burner ring
• 2 large stack burner caps
• 2 large stack burner rings
• 1 crown burner cap
• 1 crown burner ring
• 1 crown burner head
• 1 GlideRack TM oven rack
• 2 standard size racks
• 4 knobs
• Anti-tip bracket w/screws
• Meat probe
• Griddle
• Wok ring
• Stainless steel cleaner
• Literature kit
• Broiler pan/grill
See the use and care manual for a list of optional accessories.