Specifications
Bare wire
connections
Loop and
spade terminal
connections
L1 terminal
Neutral terminal
L2 terminal
Link removed _ I =
Ground screw _ --_ (_
L2 wire
Green wire
White wire
Strain relief
o
4 Wire Appliance
Cord Connection
L2
Neutral
/
L1
Ground
14-50P Plug
L1 wire
Gas Connection
NOTE: The gas pressure regulator is pre-set at the factory for
the type of gas intended for use with the appliance. To verify that
the appliance is compatible with the type of gas available, check
the range rating label (see page 3 for location). Ranges intended
for use with LP gas wilt have "LP" as a part of the model number.
Consult your dealer if the range is not compatible with the type of
gas supplied.
1. Make sure the gas supply valve is in the off position and
power to the range is off.
2. Connect a flexible gas supply line to the gas shut-off valve
previously installed on the stub out. The gas line needs to be
long enough to allow the range to be pulled out for service.
3. Slide the gas line up through the access holes in the chassis
and up to the regulator. Move the wires around inside the
access holes to prevent them from catching on the gas line
as you push it up.
4. Connect the gas line to the regulator.
5. Turn all cooktop
control valves to the 1Ill
OFF position,
_ _ Regulat°cti°_l
OFF Icon conne
,ccessI I I/
6. Turn on the gas lolesI II/
supply and check all
lines and connections _]_. __ of range j_
for leaks using a soap Gas
and water solution, line II j l
7. Turn the gas shut-
off valve to the OFF _][[
position.
_::_acar 17