Combined Configuration ER36-48D and ERV-ER

All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
COMBINATION INSTALLATIONS
ER36D, ER48D Range with ERV36-ER,
ERV48-ER Raised Vent
Document # PGCI-005
Revised 10/07/13 Page 1/1
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• All appliances must be installed in accordance with the
accompanying installation instructions.
CUTOUT DIMENSIONS
Range Model G H
ER36D 36 1/16” (91.6 cm)
33 1/2”
(84.8 cm)
ER48D 48 1/16” (122.1 cm)
43 1/2”
(110.2 cm)
*** Countertop depth is at the discretion of the customer, however,
the back of the control panel MUST be in front of the cabinet face for
safety.
G
10" (25.4 cm) min.
to combustible side
walls above the range
(both sides)
non-combustible
Minumum Countertop Height:
30 1/4” (76.8 cm)
Maximum Countertop Height:
36 1/2” (92.7 cm)
rear wall recommended
Backsplash
3/8" (1.0 cm)
Min. flat countertop
overhang
H
2 13/16"
(7.1 cm)
Note 2
CUTOUT FOR ER36D OR ER48D RANGE WITH RAISED VENT
(TOP VIEW)
APPROVED RAISED VENT MODELS
Raised Vent Model
For use with
Range Model
ERV36-ER ER36D
ERV48-ER ER48D
Stiffener
Cabinet face**
Countertop*
* IMPORTANT: See “CUTOUT WITH OPTIONAL ERV RAISED VENT”
for countertop cutout dimensions.
*** Includes 3/16” (5 mm) space between raised vent and range.
** IMPORTANT: Cabinet face must not stick out further than
back of control panel.
Back of
control
panel
ERV36-ER or
ERV48-ER
raised vent
ER36D or ER48D Range
3/8” Min. (1.0 cm)
space behind
raised vent
chassis to clear
stiffener
3/8” Min. (1.0 cm)
flat countertop
overhang required
behind cutout
31 1/2” Min. (80.0 cm)***
Countertop height:
30 1/4" (76.8 cm) Min.
36 1/2” (92.7 cm) Max.
RAISED VENT INSTALLATION
(SIDE VIEW)
***
Product tolerances: +/- 1/16” (+/- 1.6 mm) unless otherwise stated
This configuration is not compatible with cabinet blower model CABP3.