Product specifications

Page 8
Page 9
STEP 12
Gas Connection
STEP 11 (Continued)
Electrical Connection - ERD Model Ranges Only
B. Connecting the Green Appliance Wire to the Neutral (White) Supply Wire – Where Local Codes Permit
1. Connect the green and white appliance wires to the neutral (white) supply wire in the junction box.
2. Connect the black appliance wire to the black (L1) power supply wire in the junction box.
3. Connect the red appliance wire to the red (L2) power supply wire in the junction box.
C. Connecting the Green Appliance Wire to a Grounded Supply Wire or a Grounded Cold Water Pipe – Where Local Codes Permit.
1. Separate the green and white appliance wires.
2. Connect the white appliance wire to the neutral (white) supply wire in the junction box.
3. Connect the black appliance wire to the black (L1) power supply wire in the junction box.
4. Connect the red appliance wire to the red (L2) power supply wire in the junction box.
5. Connect the green appliance wire to a grounded supply wire in the junction box or to a grounded cold water pipe.
6. If connecting to a grounded cold water pipe, a separate copper grounding wire (No. 10 minimum) must be connected to a grounded cold
water pipe by means of a clamp and then to an external grounding connector screw.
Conduit from
appliance
Cable from
power supply
Wire nut
(4 places)
Junction
box
RED
RED
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Separate No. 10 (minimum)
copper grounding wire
Clamp must be
tight on pipe
No. 4
copper wire
Metal
water pipe
Clamps
Bare metal
Meter
Connecting the appliance ground to a grounded
junction box wire or grounded cold water pipe
WARNINGS:
1. Do not ground the appliance to a gas supply pipe or hot water pipe.
2. Do not turn on power to the appliance until the range is permanently grounded.
3. A grounded cold water pipe must have metal continuity to electrical ground and must not be
interrupted by insulating materials. Any insulating materials must be jumped (as shown in Figure
23 below) with a length of No. 4 copper wire securely clamped to bare metal at both ends.
Before sliding the range into the cabinet, connect a flexible gas connector to the gas shut-off valve previously installed on the stub out. The gas
valve must be turned off during installation. Connect the flex connector to the pipe fitting at the right rear of the range.
WARNINGS:
1. Do not apply excessive pressure when tightening gas connections and fittings.
2. Do not use teflon tape or plumberʼs putty on gas flex line connections.
3. Turn all cooktop control valves to the “OFF” position. Turn on gas supply and check all lines and
connections for leaks using a soap and water solution. Do not use a flame to check for leaks.
After verifying that there are no gas leaks, turn off the gas supply to the range by turning the
gas shut-off valve to the “OFF” position.
4. For LP installations, the LP gas tank must have its own high pressure regulator. This is in
addition to the pressure regulator provided with the range.
5. The maximum gas supply pressure to the regulator must never exceed 1/2 pound per square
inch.
NOTE:
The gas pressure regulator is pre-set at the factory for the type of gas intended for use with
the appliance. Verify that the appliance is compatible with the type of gas available by checking
the data plate located behind the inlet air cooling grill. Open the oven door and remove the inlet
air cooling grill for access to the data plate. Ranges intended for use with LP gases will have
“LP” as a part of the model number. Consult your dealer if the range is not compatible with
your gas supply.
STEP 13
Installing the Range
Measure from the floor to the countertop and adjust the leveling legs as required to position the top frame at the desired height, based on
the cabinet and countertop installation. Carefully slide the range into position in the cutout. The rear anti-tip leg should engage the anti-tip
bracket.(30 and 36 inch models only)
When the range is to be installed as a “slide-in, self rimming” (with the range top overhanging the countertop cutout - ERD/ERG30 models
only), measure from the floor to the countertop. Adjust the leveling legs to position the bottom edge of the range top frame approximately 1/8”
above the level of the countertop. This will allow the range to slide over the countertop. Carefully slide the range into position in the cutout. The
rear anti-tip leg should engage the anti-tip bracket. To lower the range onto the countertop, turn the leveling legs counterclockwise. Lower the
range until the bottom of the range top just contacts the countertop. Do not allow the full weight of the range to hang on the counter.