Product specifications
Page 2
Page 3
STEP 1
Verifying the Package Contents
Verify that all required components have been provided. If any item is missing or damaged, please contact your dealer immediately. Do not
install a damaged or incomplete appliance.
• Use & Care Manual • Ignitor Cleaning Kit • Broiler Pan/Grill
• Anti-tip Bracket (selected models) • Grate/Burner Cap Packs • Griddle
• Burner Rings • Wok Ring • Simmerplate
• Spatula • Stainless Steel Cleaner • Pry Stick
STEP 2
Gas Supply Requirements
Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in
accordance with the National Fuel Gas Code ANSI Z223.1. Be certain that the appliance being installed is correct for the gas service being
provided. Refer to the data plate located behind the inlet air cooling grill, and/or to Table 1 below, for gas supply requirements. Open the oven
door and remove the inlet air cooling grill for access to the data plate.
Table 1: Gas and Electrical Supply Requirements
STEP 3
Electrical Power Supply Requirements
It is the ownerʼs responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical
installation, including minimum supply wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA 70-1993*
(or latest revision) and local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a
properly sized circuit breaker or time delay fuse. Refer to the data plate, and/or to Table 1 above, for gas supply requirements.
NOTE:
The shaded areas shown in the illustrations, denote the location of the gas stub and the electrical
junction box/receptacle. These are suggested locations. For replacement purposes, the location
of the existing utilities may be utilized provided that they do not interfere with the sides or rear
of the range. If installing the gas valve behind the range, verify that local building codes will
permit this.
NOTES:
1. The power supply must be properly polarized. Reverse polarity will result in continuous sparking
of the electrodes, even after flame ignition.
2. If there is any doubt as to whether the power supply is properly polarized or grounded, have it
checked by a qualified electrician.
WARNING:
If the gas or electric service provided does not meet the product specifications, do not proceed
with the installation. Call the selling dealer, the gas supplier, or a licensed electrician.
STEP 4
Gas and Electrical Rough-In Locations
WARNING:
This appliance must be installed by a licensed plumber or gas fitter when installed within the
Commonwealth of Massachusetts.
DACOR
Model number
EGR30
EGR30LP
ERD30
ERD30LP
ERD36
ERD36LP
ERDE36
ERDE36LP
ERD48
ERD48LP
ERDE48
ERDE48LP
ERD60
ERD60LP
Electrical circuit
required
120VAC, 60Hz, 15A
120/240VAC, 60 HZ, 30A
120/240VAC, 60 HZ, 40A
120/240VAC, 60 HZ, 50A
Total
connected load
0.75kW (6A)
4.2kW (22A)
4.7kW (24A)
7.7kW (34A)
10.0kW (46A)
10.8kW (48A)
8.4kW (43A)
Gas type
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Manifold pressure
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
Min. gas supply
pressure
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column