Installation guide
Installation
Instructions
Cabinet
Blower
Installation
lf
using
cabinet
blower
(model
CABP3):
1.
Locate
the
wiring
diagram
label
included
with
the
adapter
kit.
Peel
the
protective
backing
off
and
place
it
over
the
existing
label
on
the
CABP3
blower
as
shown.
a
NL
ae”
New
label
2.
Locate
the
foam
tape
supplied
with
the
raised
vent.
Place
the
blower
on
the
floor
in
the
orientation
it
will
be
mounted
on
the
front
of
the
raised
vent.
Peel
the
back-
ing
off
the
included
foam
tape
and
attach
it
to
the
right
and
left
flanges
of
the
blower
base
plate.
3.
With
the
exhaust
in
the
desired
orientation,
slide
the
bottom
flange
of
the
CABP3
blower
base
plate
behind
the
tab
on
the
bottom
of
the
adapter
mounted
to
the
front
of
the
raised
vent.
4.
Cover
the
opening
on
the
adapter
by
pushing
the
blower
against
it.
Make
sure
that
the
foam
tape
cre-
ates
a
good
seal
on
the
right
and
left
side
of
the
open-
ing.
Center
the
blower
base
plate
horizontally
over
the
opening
on
the
front
of
the
adapter.
5.
Install
the
adapter
top
retainer
bracket
over
the
blower
base
plate
flange.
Secure
it
in
place
with
the
three
(3)
wing
nuts, lock
washers
and
flat
washers
included
with
the
adapter.
Top
retainer
Attach
foam
to
right/left
flanges
|
Adapter
\
Insert
bottom
flange
into
tab
at
bottom
of
adapter
ILHSF
or
REMP
Series
Blower
Installation
if
using
a
ILHSF
or
REMP
series
blower,
install
it
according
to
the
blower
installation
instructions.
Duct
Work
Installation
install
the
duct
work
according
to
the
Installation
Specifications
section.
Use
sheet
metal
screws
and
duct
tape
to
connect
and
seal
all
of
the
pieces.
Support
the
duct
weight
as
necessary
to
ensure
sealed
joints.
Electrical
Installation
WARNING
°
ELECTRIC
SHOCK
HAZARD
.-
Do
not
connect
the
raised:
vent
power
plug
to
the
electrical
outlet
until
installation
is
complete.
«Failure
to-complete
electrical
connections
properly
may
result
in-an
electric
shock
hazard
or
a
damaged
or
non-functional
system.
Follow-the
wiring
diagrams
carefully.
to
ensure
a-proper
installation.
Do
not
change
the
factory.
wired.
terminal
connections
inside
the
electrical
access
panel
for
the
raised
vent
or
the
blower.
*
To
avoid an-electric
shock
hazard
and
to.prevent
dam-
age
route-all
wiring
away.
from
hot
surfaces.
1.
For
ILHSF
and
REMP
blower
installations,
run
the
wir-
ing/conduit
line
used
to
supply
power
from
the
raised
vent
to
the
blower
parallel
to
the
duct
work.
2.
Remove
the
cover
from
the
raised
vent
electrical
access
panel.
3.
Connect
the
wiring/conduit
to
the
blower
as
shown
in
the
wiring
diagrams
below
and
the
facing
page
accord-
ing
to
local
codes
and
ordinances.
Make
sure
all
ter-
minal
connections,
including
the
factory
wired
connec-
tions,
are
tight.
Replace
the
electrical
access
panel.
Range/Cooktop
Installation
install
the
range
or
cooktop
according
to
its
installation
instructions.
12