Installation guide

Installation
Specifications
Planning
the
Duct
Work
WARNING
will
also
improve
system
efficiency.
«To
reduce
the
risk
of
fire
and
to
properly
exhaust.
air,
be
sure.to
duct-air
outside
the
house
or-building.
Do
not
vent
exhaust.air
into
spaces.
within
walls
or
ceilings
or
into
attics,
crawl_
spaces
or
garages.
*-Tape-all
duct
joints
securely.to
prevent
combustion
by-products,
smoke
or
odors
from
entering
the
home.
Doing
so
«TO
REDUCE
THE
RISK
OF
FIRE,
USE
ONLY
METAL
DUCT
WORK.
«
~.-DO.NOT
install
more
than
one
blower.
to
increase
the
length
of
the
duct-run.
Even
small
differences
between
blower
air
flow-rates
can
greatly
reduce
the
air
draw
by-the
raised
vent.
You
must
install
one
of
the
Dacor
remote
or
in-line
blower
models
listed
below
for
the
raised
vent
to
operate
properly.
See
the
blower
installation
instructions
for
directions.
Only
one
blower
shall
be
installed.
APPROVED
DACOR
BLOWERS
FOR
USE
WITH
MODEL
ERV36-ER
AND
ERV48-ER
RAISED
VENTS
Model
Number
REMP3
|
REMP16
|
ILHSF8
|
ILHSF10
Rating*
|
600
CFM
|
1000
CFM
|
600
CFM
|
1100
CFM
*
Nominal
rating
at
zero
inches
static
pressure.
See
blower
installation
instructions
for
actual
ratings.
The
ERV
raised
vent
can
be
configured
to
exhaust
through
the
back,
the
bottom
or
either
side
by
removing
the
appropriate
exhaust
knock
out
shown
below.
oF
|
6
1/4"
(159
mm)
———|
¢g
38
|
{
©
©
(29
mm)
a
NI
Front
of
unit
Ai
Motor
©
OS
Nf,
oth
yd!
4
rs
@ @
8
z
¢@
@@®
@
Rear
Exhaust
Knock
Out
(3
1/4”
X
10”)
Vertical
center
line
of
rear
exhaust
knock
out
lines
up with
vertical
center
line
of
chassis
Bottom
Exhaust
Knock
Out
(1
5/8”
X
16”)
®
On
46’
and
48”
wide
models,
the
vertical
center
line
of
bottom
knock:
out
lines
up
with
vertical
center
line
of
chassis
©®
On
30”
and
36”
wide
models,
the
vertical
center
line
of
bottom
knock.
out
is
offset
3”
©
Side
Exhaust
Knock
Outs
(1
5/8”
X
16”)
26"
(660
mm)
When
connecting
the
duct
work
to
the
back
of
the
unit,
the
customer
must
supply
a 3
%”
X
10”
rectangular
transition
to
make
the
connection.
For
side
and
bottom
exhaust
connections,
use
the
sup-
plied
ATD2
transition
to
connect
the
duct
work
to
the
unit.
It
transitions
between
the
1
5/8”
X
16”
exhaust
outlet
on
the
unit
and
a 3
%”
X
10”
rectangular
duct
connection.
On
bottom
exhaust
installations
cut
a
hole
in
the
floor
to
allow
the
transition
and/or
duct
work
to
pass
through
the
floor
(see
page
8).
ADT2
Transition
2”
X
16”,
connects
to
5"
side
or
bottom
exhaust
“oe
J
on
raised vent
4"
(25
mm)
3
1/4”
X
10”
to
duct
work
All
duct
work
materials
(including
screws
and
duct
tape)
must
be
purchased
separately
by
the
customer.
When
planning
new
duct
work,
always
look
for
the
shortest,
most
direct
route
to
the
outside.
See
page
5
for
examples.
You
can
increase
the
duct
size
over
the
duct
run
if
desired.
To
prevent
a
back
draft,
never
decrease
the
duct
size
over
the
run.
Do
not
rely
on
duct
tape
alone
to
seal
duct
joints.
Fasten
all
connections
with
sheet
metal
screws
and
tape
all
joints
with
certified
silver
tape
or
duct
tape.
Use
sheet
metal
screws
as
required
to
support
the
duct
weight.
To
prevent
back-drafts,
a
damper
at
the
duct
outlet
may
also
be
required.
6