How To Guide

PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specications are subject to change without notice.
See installation instructions for additional details.
2.3
24”, 27”, 30”, 36”
Wide Warming Drawers
ERWD, EWD, IWD, MRWD, MWDV, MWDH,
OWD and PWD
Document # PG02 - 002 Revised 11/19/09 Page 3/3
Warming drawer
Cooktop
1 1/2" (38 mm)
Typical countertop
3/4” Min.*
(19 mm)
120 Vac
electrical
outlet
A
36" Typ.
(914 mm)
B
C
27"/30"/36"
Dacor
single oven
Warming drawer
Warming drawer
Toe kick
D
C
D
C
120 Vac
elect.
120 Vac
elect.
A
3/4" Min.*
(19 mm)
Cabinet/countertop tolerances: +1/16” (+1.6 mm) -0 unless otherwise stated
* Bare minimum spacing to allow for ventilation and avoid scraping on EWD, MW and PWD series models.
** On IWD series models or OWD24 without the optional front panel kit: The chassis and the drawer faceplate are smaller than the cutout.
The custom front panel mounts to the drawer faceplate. The height and width of the custom front panel must exceed the appropriate cutout
dimensions (A and C above) to cover the hole. Allow 1/4" minimum additional space on the top, bottom and sides from the custom front panel
edge to prevent scraping against adjacent doors, drawers and the countertop.
*** OWD24 with optional factory front panel kit only. Bare minimum spacing shown to avoid scraping. Gap above and below cutout is 3/4”
minimum. See ** above for OWD24 with custom front panel.
**** This model cannot be installed above or below another warming drawer (any type).
***** Model OWD24 cannot be installed above, below or adjacent to a wall oven or warming drawer (any type).
Model (A) Cutout Width
(B) Min. Width to
Adjacent Doors/
Drawers
(C) Cutout Height
(D) Min. Vertical Gap
Between Cutouts
Min. Cutout Depth
ERWD30 28 1/2” (724 mm) 30 1/4” (768 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
EWD24 22 1/2” (572 mm) 24 1/4” (616 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
24” (610 mm)
EWD27 25 1/2” (648 mm) 27 1/4” (692 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
EWD30 28 1/2” (724 mm) 30 1/4” (768 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
EWD36**** 34 1/2” (876 mm) 36 1/4” (921 mm)* 9 1/8” (232 mm) NA
IWD24**** 22 1/2” (572 mm) ** 9 1/8” (232 mm) NA
IWD27**** 25 1/2” (648 mm) ** 9 1/8” (232 mm) NA
IWD30**** 28 1/2” (724 mm) ** 9 1/8” (232 mm) NA
MRWD27 25 1/2” (648 mm) 27 1/4” (692 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
MRWD30 28 1/2” (724 mm) 30 1/4” (768 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
MWDH27 25 1/2” (648 mm) 27 1/4” (692 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
MWDH30 28 1/2” (724 mm) 30 1/4” (768 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
MWDV27 25 1/2” (648 mm) 27 1/4” (692 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
MWDV30 28 1/2” (724 mm) 30 1/4” (768 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
OWD24***** 22 5/8” (575 mm) 24 1/4” (616 mm)*** 11 15/16” (303 mm) NA 20 1/8” (511 mm)
PWD27 25 1/2” (648 mm) 27 1/4” (692 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
24” (610 mm)
PWD30 28 1/2” (724 mm) 30 1/4” (768 mm)* 9 1/8” (232 mm) 1 1/4” (32 mm)*
WARNING
Observe all governing codes and ordinances •
during planning and installation. Contact your
local building department for further information.
This appliance must be installed in accordance •
with the accompanying installation instructions.
Mounting platform must be 3/4" (19 mm) thick
and support 100 lbs.