installation instructions

10
Removing the Oven Door
WARNING
With the door off the range, do not remove the hinge catches. The
springs could release abruptly, causing personal injury.
Do not lift/carry the oven door by the handle.
So the range is easier to move, remove the door to reduce weight.
1. Open the door fully.
2. With needle-nose pliers and a flat-blade screwdriver, flip the catch
out over each retaining arm.
3. Lift the oven door to 15° from vertical, and, grasping each side just
below the handle, lift it away from the oven.
Gas Connection
WARNING
Do not overtighten the gas connections/fittings.
Do not use Teflon tape or plumber’s putty on flex-line connections.
For LP gas, the tank must have its own high-pressure regulator (in
addition to the range’s regulator).
The maximum gas-supply pressure to the regulator must not
exceed ½ psi (pound per sq. in.) or 3.5 kPa.
The range and shut-off valve must be disconnected from the gas-
supply piping for pressure testing over ½ psi (3.5 kPa).
You must close the gas shut-off valve during pressure testing at or
below ½ psi (3.5 kPa).
Check all gas lines for leaks as directed to avoid a fire or explosion
hazard. (Do not use a flame to check for leaks.)
NOTE: The gas-pressure regulator is factory-set for LP or natural gas.
To verify that the range is compatible with the home gas supply, check
the range rating label (see inside cover for location). Ranges set up for
LP gas have LP in the model number. Consult your dealer if the range is
incompatible with the home gas supply.
1. Close the gas-supply valve, and unplug the range.
2. Connect a flexible gas-supply line to the shut-off valve on the stub out.
The gas line must be long enough that the range can be pulled out
for service without disconnecting the flex line.
3. Slide the gas line up through
the access holes in the chassis
to the regulator. (Move the wires
inside the access holes so they
do not catch on the line.)
4. Connect the gas line to the
regulator.
5. Turn all control knobs off, and
open the gas valve.
6. With a soap-and-water
solution, check all lines and
connections for leaks.
7. Close the range’s gas valve.
Regulator
connection
Retaining arm
Catch
Installation Instructions