Installation Sheet

6
Gas and Electrical Service
The shaded area shown below denotes the location of the
gas inlet and the electrical outlet. This is the recommended
location. For replacement purposes, the location of the
existing utilities may be utilized provided they do not interfere
with the sides or rear of the range. Check local building codes
for permissible gas valve locations.
An external manual shut-off valve must be installed between
the gas inlet and the range for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the electrical outlet, when the range is in place.
The gas supply piping and shut-off valve, and the electrical
outlet must be located so they do not interfere with the range
when it is installed.
The electrical outlet and gas shut off valve must be located
so that the range can be pulled out for service while the
appliance remains connected.
Planning the Installation
Range Model Downdraft Vent Model
RNRP36G ERV36-ER
RNRP48G ERV48-ER
Range Model
1.5” Low-Profile Backguard
Model
RNRP36G APB36GLP
RNRP48G APB48GLP