Planning Guide

All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
4.24
DTCT304, DTCT365, DTCT466
Distinctive
®
30”, 36” and 46” Wide
Drop-in Gas Cooktops
Document # PG04-008
Revised 11/05/15 Page 4/5
All tolerances: +1/16” -0” unless otherwise noted.
Cabinet and Countertop Layout
WARNING
To reduce the risk of personal injury caused by reaching
over a hot appliance, avoid locating cabinet storage space
directly above the cooktop.
Failure to meet or exceed the maximum and minimum
dimensions/clearances stated in these instructions may
result in a fire hazard.
Follow the countertop manufacturer’s instructions regarding
the minimum corner radius, use of heat reflective tape,
reinforcement of corners, etc.
Carefully check the location where the cooktop will be installed.
For best performance, the cooktop should be placed away from
drafts that may be caused by doors, windows and heating and air
conditioning outlets.
This appliance is to be used in conjunction with a suitable vent hood
or approved Dacor downdraft.
CLEARANCE REQUIREMENTS
Model A: Minimum A: Recommended
DTCT304G 30 in (76.2 cm) 36 in (91.4 cm)
DTCT365G 36 in (91.4 cm) 42 in (106.7 cm)
DTCT466G 46 in (121.9 cm) 54 in (137.2 cm)
13 in max.
3
(33.0 cm)
3
Not applicable for cabinets mor
e than a horizontal distance of 6 in.
(15.2 cm) from edge of cooktop. Allow 7 1/2 in
(19.1 cm) from edge
of cutout.
A
See cutout
dimensions
15 in min.
1
,
3
(45.7 cm)
1 7/8 in min.
(4.8 cm)
Combustible
surface to rear
Combustible overhead
cabinets
30 in min.
1
,
2
(76.2 cm)
7 1/2 in (19.1 cm) min. to
combustible side wall,
above counter (on both sides)
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
1
Measured from top of cooktop grate.
Allow a minimum 1/4 in (6 mm) clearance between
the bottom of the cooktop chassis and
all combustible surfaces, including the edges and corners of drawers
that sit below the cooktop.
Minimum Clearance for Hold-Down Brackets
Model B
DTCT304G 29 in (73.7 cm)
DTCT365G 35 1/4 in (89.5 cm)
DTCT466G 45 1/4 in (114.64 cm)
Allow clearance for hold-down brackets.
The gas supply piping, gas shut-off valve, and the electrical outlet
must be placed so they do not interfere with the cooktop when it is
installed.
If installing another appliance in the cabinet below, allow for the
routing of gas and power behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator after the unit is
installed.
That the 40-inch (101.6 cm) power cord must be able to reach
an electrical outlet, and that outlet must be accessable when the
cooktop is in place.
Access to the underside of the cooktop for service and inspection
purposes.
Clearance inside the cabinet to allow for proper hold- down bracket
installation.
For access to the underneath of the cooktop, a fixed shelf should
not be installed below the cooktop.
Downdraft Compatibility
If installing the cooktop with a downdraft, use only the approved Dacor
model numbers specified below:
Cooktop Models:
Use with These Approved Downdraft
Models:
DTCT304G ERV3015, PRV30, RV30
DTCT365G ERV3615, PRV36, RV36
DTCT466G PRV46, RV46
1/4” (6 mm)
min. clearance
to combustible
surfaces
B