Cabinet and Countertop Layout
WARNING
To reduce risk of personal injury from reaching over a hot cooktop,
avoid cabinet storage over the cooktop.
Failure to meet or exceed the maximum and minimum dimensions/
clearances as instructed may cause a fire hazard.
Follow the countertop manufacturers instructions regarding all
aspects of countertop installation.
Carefully check the cooktop installation site. Situate the
cooktop away from drafts and wet areas.
Use the cooktop with a suitable vent hood or approved Dacor
downdraft.
Installation must allow:
at least ” (6 mm) clearance between the bottom of the
cooktop chassis and all combustible surfaces, including the
edges and corners of drawers under the cooktop.
clearance for hold-down brackets
The gas supply piping, gas shut-off valve, and electrical outlet
must not interfere with the installed cooktop.
If installing an appliance below the cooktop, allow for routing of
utilities behind it.
access to the gas shut-off valve and regulator without moving
the cooktop.
the 40” (101.6 cm) power cord to reach an electrical outlet, and
outlet to be accessable without moving the cooktop.
access to the cooktop bottom for service/maintenance.(Do not
install fixed shelving below the cooktop.)
Downdraft Compatibility
If installing the cooktop with a downdraft, use only the approved
Dacor model numbers PRV46 or RV46. (See Pg. 4.)
Heritage
®
46” Wide
Drop-In Gas Cooktop
Page 3 of 4
All tolerances: ±¹/₁₆ (±1.6 mm) unless otherwise stated.
HPCT466G
Callout Description
1 Measured from top of cooktop grate
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
3
Not applicable for cabinets more than a horizontal distance
of 6” (15.2 cm) from edge of cooktop; allow 7 ” (19.1 cm)