installation instructions

3
Product Dimensions
WIDTH (A)
DYRTP366, HRTP366 35 7/8” (91.1 cm)
DYRTP486, HRTP486 47 7/8” (121.6 cm)
Installation Requirements
WARNING
The installation of this appliance must conform with
local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
To prevent an electric shock hazard, the power sup-
ply must meet the specifications stated below.
The electrical and gas supply data on this page is for refer-
ence only. If the requirements below do not agree with the
product data label, use the data on the product data label.
Electrical Requirements
The appliance installation must be electrically grounded
in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/
NFPA 70.
The correct voltage, frequency and amperage must be
supplied to the electrical outlet according to the product
data label located on the bottom of the chassis.
The electrical outlet must be installed by a licensed
electrician in an accessible location so that the power
cord may easily be disconnected during cleaning and
service.
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
120 Vac 60 Hz,
15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
Gas Supply Requirements
Check your local building codes for the proper method
of installation. In the absence of local codes, this
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54. The
gas service must be installed by a qualified profes-
sional.
Be certain that the rangetop being installed is cor-
rect for the gas service being provided (natural gas or
LP gas). Also, if operating the rangetop at an altitude
above 4000 ft. (1219 m) make sure it is equipped for
high altitude operation. See the inside cover for more
information.
An external manual shut-off valve must be installed
between the gas inlet and the rangetop for the purpose
of turning on or shutting off gas to the appliance.
The factory provided regulator shipped with the appli-
ance must be installed in the gas line that runs from the
gas shut off valve to the rangetop gas inlet. Use only
the regulator provided. The regulator inlet accommo-
dates a 3/4” gas supply line and is also compatible with
a 1/2” house gas supply. The inlet to the rangetop itself
is equipped with a 3/4” male NPT fitting.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold
Pressure
Minimum Gas
Supply Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP)
10” Water
Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 psi
A
3 3/8”
(8.6 cm)
7/16”
(1.1 cm)
7 3/4”
(19.7 cm)
Trim:
1/4”
(6.4 mm)
thick
25 3/8” (64.5 cm)
1 1/4” (3.2 cm) cooking surface
height (grate level) above
countertop
3/4” NPT gas inlet, connects to regulator
from bottom or rear of unit, end is recessed
2” (5.1 cm) from chassis bottom
26 5/16” (66.8 cm)
27 5/16” (69.4 cm)
Power cord
40” long
Product tolerances: ±1/16” (±1.6 mm) unless otherwise
noted.
SIDE VIEW