installation instructions

6
Cabinet/Countertop Dimensions (cont.)
Installation Requirements
Cutout tolerances +1/16” (+1.6 mm) -0 unless otherwise noted
Non-combustible
rear wall, rear of
mounting platform
10” (25.4 cm) min.
to combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
Increase countertop and overhang
additional 2 1/2” (6.4 cm) min. for
combustible rear wall above
countertop
3/8” (1.3 cm)
countertop overhang
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
Gas/electrical utility cut-out in right rear corner of
mounting platform 8” W X 6” D (20.3 cm X 15.2 cm),
if gas and electrical are routed through bottom
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
Countertop
Countertop
1/2” (1.3 cm)
countertop
overhang
2” (5.1 cm)
Counterop
overhang
1” (2.5 cm)
typical
1 3/8”
(3.5 cm)
max.
11 7/16”
(29.1 cm)
24”
(63.5 cm)
min.
cabinet
depth
C
L
D D
B
C
L
C
L
C
L
Rangetop
Model
B - Cutout
Width
D - Hole
Offset
E - Downdraft
Vent Cutout
Approved Downdraft
Vent Models
DYRTP366,
HRTP366
36”
(91.4 cm)
16 5/8”
(42.2 cm)
33 1/2”
(85.1 cm)
ERV36, ERV3615,
PRV36
DYRTP486,
HRTP486
48”
(121.9 cm)
20 13/16”
(52.9 cm)
43 1/2”
(110.5 cm)
ERV48, PRV48
Cabinet/Countertop Cutout Dimensions without Downdraft Vent - Top View
Installed Rangetop - Side View
Gas connection and power cord may be
routed through bottom or back of chassis
Gas and electrical connections at
right rear section of chassis
Cabinet
face
Installed control
panel overhang
1/3/8” (3.5 cm)
24” (61.0 cm)
Countertop
Mounting platform
IMPORTANT: Use only the downdraft vent models specified.