Installation Instructions
The Dacor integrated hood liner (IHL) is constructed
with non-combustible stainless steel material. The IHL
dimensions and design make it an excellent component
for any custom hood structure. Dacor offers two integrated
ventilation system products (IVS1 and IVS2) which
conveniently install on the pre-mounted installation lugs
around the opening at the top of the hood liner.
Plan the installation so that all minimum clearances are
met or exceeded. Dimensions shown provide minimum
clearances, unless otherwise noted.
Installation Planning
NOTES:
Dacor IHLs have no electrical parts.•
#8 mounting screws (not provided) are required to •
install the IHL. The length and type must be determined
according to the application (mounting material). See
the diagrams below to determine the quantity required
for the model being installed.
For proper installation of the complete IHL/IVS custom •
hood ventilation system, the installer must follow
the installation information in the IVS Installation
Instructions. Follow all electrical requirements specified
in the IVS Installation Instructions.
The IVS is attached to the IHL using the 8-32 cap nuts •
and lock washers provided with the IHL kit. Quantity
varies according to kit.
The IHL is designed for vertical on center ducting •
applications only.
The IHL30 and IHL36 liners are designed for installation
with the 600CFM IVS1 integrated ventilation system.
For additional specifications refer to the IVS Installation
Instructions.
21"
(53.3 cm)
4" (10.2 cm)
B
Model
IHL42
IHL48
IHL54
(B)
39" (99.1 cm)
45" (114.3 cm)
51" (129.5 cm)
IVS2 mounting
studs (12 places)
IVS2 integrated
ventilation system
IHL mounting hole
(6 places)
13 7/16"
(34.1 cm)
C
L
Figure 2: IHL42/48/54 Overall Dimensions
Top View
13 7/16"
(34.1 cm)
21"
(53.3 cm)
4" (10.2 cm)
A
Model
IHL30
IHL36
(A)
27" (68.6 cm)
33" (83.8 cm)
IVS1 mounting
studs (6 places)
IVS1 integrated
ventilation system
IHL mounting hole
(4 places)
C
L
Figure 1: IHL30/36 Overall Dimensions
Top View
The IHL42, IHL48 and IHL54 liners are designed for
installation with the 1200CFM IVS2 integrated ventilation
system. For additional specifications refer to the IVS
Installation Instructions.