Ventilation Solutions
1 Ventilation Facts POLLUTANTS TO REMOVE FROM THE KITCHEN Heat, Odors, Grease, Gases, Steam & Smoke FACTORS THAT NEGATIVELY INFLUENCE VENTILATION Open Windows & Doors, Air Conditioning Vents, Ceiling Fans, Island Cooking, Foot Traffic GENERAL RULE OF THUMB 100 CFM for every 10,000 BTU (*Increase if duct run is long or complicated) Two Types of Ventilation Power Sources Factors to Consider Width & Depth of Cooking Product 1 OVERHEAD Hoods Internal Blowers Powerpacks External Blowers: REMP3, RE
2 Ventilation Facts Hoods: EH/EHR/MH - Bottom of the hood should be 25” minimum above the cooktop surface. DHI, DHW, PHW - Bottom of the hood should be 30” minimum above the cooktop surface. PowerPacks (with SS Liner): Bottom of liner should be 36" from the finished counter. RECOMMENDED MOUNTING HEIGHTS OTR (above electric cooking): Top of microwave should be 34" above the finished counter. OTR (above gas cooking): Top of microwave should be 36" above the finished counter.
3 Pro-Style Hoods 18" Epicure Hoods 18" High, 267/8" Deep EH5418, EH4818, EH4218, EH3618, EH3018, EHR5418, EHR4818, EHR4218, EHR3618, EHR3018 WIDTHS 54", 48”, 42”, 36” and 30” FINISHES Stainless Steel in standard Chrome trim. Three trim finish options are available in Black Chrome, Brass or Copper. INTERNAL POWERED–EH MODELS 600 CFM (582 CFM at 0.0” static pressure) - EH4218, EH3618 & EH3018 1200 CFM (1164 at 0.
4 Millennia Hoods 18" Millennia Hoods 18" High, 251/2" Deep MH4818, MH3618, MH3018 WIDTHS 48", 36” and 30” FINISH Stainless Steel INTERNAL POWERED–MH MODELS 600 CFM (582 CFM at 0.0” static pressure) - MH3618 or MH3018 1200 CFM (1164 at 0.
5 EH and MH Hoods Blower Performance Curves Centrifugal Blower 2.10 1.80 3 ed Spe 1.20 1.50 1.25 1.00 .30 .25 Sp ee d d3 ee Sp .50 1 d ee Sp .75 0 4 0 130 195 260 325 390 455 545 50 3 2.00 1.75 250 300 350 400 1 2.10 1.80 1.50 ed Spe .90 3 d4 ee Sp .75 200 2.40 1.20 d3 ee Sp d2 ee Sp 1.00 150 1 eed Sp 1 1.25 100 2 ed Spe d ee Sp 1.50 Static pressure - inches of water 65 Static pressure - inches of water 1.75 .60 d ee Sp .50 2 2.
6 Millennia Hoods Millennia Island Hoods - DHI602, DHI542, DHI482, DHI421, DHI361 WIDTHS 60”, 54”, 48”, 42” & 36” FINISH Stainless Steel INTERNAL POWERED 1200 CFM (1164 at 0.0” static pressure) - DHI602, DHI542, DHI482 600 CFM (582 CFM at 0.0” static pressure) - DHI421, DHI361 VENTING Vents out the top (vertically), 8” round Millennia Chimney Hoods - DHW482, DHW421, DHW361, DHW301 WIDTHS 48”, 42”, 36” & 30” FINISH Stainless Steel INTERNAL POWERED 1200 CFM (1164 at 0.
7 PowerPacks IVS1 or IVSR1 DIMENSIONS 22 5⁄8" wide, 12 1⁄4" deep, 6" high INTERNAL POWERED – IVS1 600 CFM (582 CFM at 0.0” static pressure) EXTERNAL POWERED – IVSR1 (REMOTE BLOWER OPTION only one blower allowed per installation) Use REMP3 – 600 CFM (572 CFM at 0.0” static pressure) Use ILHSF8 – 600 CFM (650 CFM at 0.
8 Blower Performance Curve IVS1 Static pressure - inches of water IVS1 .75 .60 .45 .30 .
9 Over the Range Microwaves PMOR3021 FINISHES Stainless Steel, Black or White INTERNAL POWERED 300 CFM EXTERNAL POWERED (OPTIONAL REMOTE BLOWER) INSTALLER 600 CFM Use ILHSF8 600 CFM (650 CFM at 0.
10 Downdraft Systems RV46, RV36, RV30 SIZES 46," 36" & 30" FINISHES Stainless Steel, Black or White INTERNAL POWERED Use CABP3 blower – 600 CFM EXTERNAL POWERED (REMOTE BLOWER OPTION - only one blower allowed per installation) REMP3–600 CFM, 8" round duct (572 CFM at 0.0” static pressure) REMP16–1000 CFM, 10" round duct (980 CFM at 0.0” static pressure) ILHSF8-600 CFM (650 CFM at 0.0” static pressure), 8” round duct ILHSF10-1100 CFM (1116 CFM at 0.
11 Accessories Remote Blower Internal Blower REMP3 (shown) - 600 CFM CABP3 - 600 CFM REMP16 - 1,000 CFM APPLICATIONS: APPLICATIONS: Use with EHR, IVSR, RV, ERV or PRV systems Stainless Steel Liners for PowerPacks Install with RV model downdrafts only Stainless Steel Duct Covers SIZES SIZES Available in five widths: 54," 48," 42," 36" & 30" Available in five widths: 54," 48," 42," 36" & 30"All widths available in three heights: 6," 12" & 18 IHL36 & IHL30 Use with IVS1 & IVSR1 IHL54, IHL48 & IH
12 Static pressure - inches of water Blower Performance Curve REMP3 REMP3 4.00 3.50 3.00 2.50 2.00 1.50 1.00 .
13 Blower Performance Curve REMP16 Static pressure - inches of water REMP16 2.50 2.00 1.50 1.00 .50 0.
14 Blower Performance Curve CABP3 Static pressure - inches of water CABP3 4.00 3.50 3.00 2.50 2.00 1.50 1.00 0.50 0.
15 In-Line Blowers ILHSF8 POWER 600 CFM (650 CFM at 0.0” static pressure) VENTING 8" round duct APPLICATIONS In-line Blower for a remote application MAKE-UP OR REPLACEMENT AIR SYSTEM Have your builder contact their HVAC contractor to see if this is required in your area. ILHSF10 POWER 1100 CFM (1116 CFM at 0.
16 Creating the Proper Ventilation System 1 Select Cooking Product COOKING PRODUCT MODEL HOOD INTEGRATED VENT SYSTEM OVER THE RANGE (OTC) RAISED VENT SYSTEM ER48D EH5418 or EHR5418 EH4818 or EHR4818 EH4812 or EHR4812 MH4818, MH4812 DHI542, DHI482, DHW482 IVS2 or IVSR2 Plus IHL54 or IHL48 NA ERV48-ER (must use remote blower) ER36D EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618 EH3612 or EHR3612 MH3618, MH3612 DHI421, DHI361 DHW421, DHW361 PHW+PHG36+Color IVS2 or IVSR2 + IHL42 IVS1 or IVS
17 Creating the Proper Ventilation System 2 Selecting Cooking Product COOKING PRODUCT INTEGRATED VENT SYSTEM OVER THE RANGE (OTR) MODEL HOOD RGC365 SGM365 EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618 EH3612 or EHR3612 MH3618 or MH3612 DHI421 or DHI361 DHW421 or DHW361 PHW+PHG36+Color RGC304 SGM304 EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012 MH3618 or MH3612 MH3018 or MH3012 DHI361 DHW361 or DHW301 PHW+PHG36+Color PHW+PHG30+Color IVS1 or IVSR1 + IHL36 or IHL30
18 Creating the Proper Ventilation System 3 Build the Ventilation Package STEP: Select Vent System / Model VENT SYSTEMS Select Blower EH4218 Included 600 CFM (582 at 0.0” static pressure) NA (one) 8" round 60' EH5418 NA NA REMP3 REMP16 ILHSF8 ILHSF10 NA REMP16 or ILHSF10 Included 600 CFM (582 at 0.0” static pressure) NA EHR5418 EHR4818 EH4212 EH3612 EH3012 EH4812 (two) 8" round Included 1200 CFM (1164 at 0.
19 Creating the Proper Ventilation System 4 Build the Ventilation Package 2 3 Select Blower Duct Size Needed (minimum) 1 Select Vent System / Model VENT SYSTEMS MODEL INTERNAL POWER REMOTE POWER DUCT SIZE MAX LENGTH MH3618 MH3018 Included 600 CFM (582 at 0.0” static pressure) NA (one) 8" round 60' MH4818 Included 1200 CFM (1164 at 0.0” static pressure) NA MH3612 MH3012 Included 600 CFM (582 at 0.0” static pressure) NA MH4812 Included 1200 CFM (1164 at 0.
20 Creating the Proper Ventilation System 5 Build the Ventilation Package STEP: Select Vent System / Model VENT SYSTEMS 3 4 Select Liner & Transition Duct Size Needed (minimum) Max Length for 1 Blower System Determine Duct Length Incl. Elbows & Trans. DUCT LENGTH 2 1 Select Blower 5 6 MODEL INTERNAL POWER REMOTE POWER LINER TRANSITION DUCT SIZE MAX LENGTH IVS1 Included 600 CFM (582 at 0.0” static pressure) NA IHL36 or IHL30 NA 8" round 60' IVS2 Included 1200 CFM (1164 at 0.
Ventilation Solutions ©Copyright 2009 Dacor, Inc. All rights reserved. L65348 011509 800.793.0093 www.dacor.