cdacor Tenants Installation Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Part No. 65278 Rev.
Table of Contents Important Safety INStruCtiONS .........cccceeeeeseseseseeereerereeees Important Information About Safety Instructions.............. General Safety Precautions .............c.cccccccccccceeeeeeeeeeenenenes Product Specifications ...........ccccccceccececeeeeeeeeeeeseneneneeeeeeeees General Specifications .............ccccccscseseceeeeseeeeeeeeeeeeeeeneneees Product DIMENSIONS .............cccceeeeeeeeeeeceeeeeeeeeeeeeeteeeeeneees Installation REQuireMent..........
Important Safety Instructions Important Information About Safety Instructions * Safety Symbols and Labels BN elat The Important Safety Instructions and warnings in Immediate hazards that WILL result in severe personal these instructions are not meant to cover all possible injury or death. problems and conditions that can occur. Use common sense and caution when installing, maintaining or WARNING operating this or any other appliance.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when precautions, including the following: using your appliance, follow basic safety WARNING Do not install or operate this appliance if it has been damaged, dropped, has damaged electrical wires or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
Product Specifications General Specifications Filters The Dacor Integrated Ventilation System (IVS) is designed for installation inside custom hood canopies. Proper installation of the IVS requires proper selection of the custom canopy materials and proper construction. Carefully and closely follow all instructions and warnings concerning Mesh type, dishwasher safe Lights 120 Vac, 75 Wait, halogen Total Circuit Requirements* 120 Vac, 60 Hz., 15 Amp. Min.
Installation Planning Installation Requirements . An IVS installed in a custom hood canopy that is constructed of non-combustible materials must be installed with the non-combustible material structure a minimum of 30” (762mm) above the appliance cooking surface. . An IVS installed in a custom hood canopy that is constructed with a Dacor IHL series stainless steel hood liner must be installed with the non-combustible material structure a minimum of 30” (762mm) above the appliance cooking surface. .
Installation Planning * To prevent back-drafts, a damper at the duct outlet may also be required. The IVS comes equipped with a backdraft damper installed in the collar of the unit. * Make sure duct work does not interfere with floor joists or wall studs. * The hood exhaust connects to a 8-inch round duct. You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run.
Installation Installing the IVS Instructions Electrical Connection WARNING [A] WARNING To avoid an electric shock hazard, do not connect the wiring hamess until after the IVS is installed in the cutout and the duct work is installed. If installing a hood liner (Dacor series IHL) install it before installing the IVS. Remove the filters from the IVS. The IVS comes pre-wired from the factory. Insert the unit into the cutout while routing the wiring harness to the junction box. 4.
Installation Verifying Proper Operation 1. Install the filters. 2. Install the light bulbs. * Instructions Installation Checklist WARNING ' : Jo ensure a Safe and proper installation, the Attach the included suction cup to one of the following checklist should be completed by the provided light bulbs. + — Insert it into one of the light fixtures. installer to ensure that no part of the installation has been overlooked. * Screw it into place and remove the section cup.
Wiring Diagrams GROUND NEUTRAL Ma 2 WH LINE BLK LAMP. DIMMER HALOGEN LIGHTS (2) ¢PX AAA A/\—# x ¥ BLK { FAN MOTOR FAN SWITCH WH IVS1, IVSR1 GROUND NEUTRAL LINE WH BLK LAMP DIMMER t WH © HALOGEN LIGHTS (3) xy BLK FAN MOTORS t—{\))— IVS2, IVSR2 8) dacor t+ ' BLK | BLK A WH <0) yy FAN SWITCH BLK
cdacor The Life of the Kitchen® Dacor e 600 Anton Bivd. Suite 1000 Costa Mesa, CA 92626 « Phone: (800) 793-0093 American Made* Family Owned e Fax: (626) 403-3130 « www.Dacor.