Specifications
Electrical Power Supply
Requirements
It is the owner's responsibility to ensure
that the electrical connection of this
appliance is performed by a qualified
electrician. The electrical installation,
including minimum supply wire size and
grounding, must be in accordance with
the National Electric Code ANSI/NFPA
70-2002* (or latest revision) and local
codes and ordinances.
*A copy of this standard may be obtained
from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and
amperage must be supplied to the
appliance from a separate, grounded,
circuit that is protected by a properly sized
circuit breaker or time delay fuse.
Dedicated Total
Electrical Connected
Circuit Required Load
120/240Vac,
4-wire, 60Hz., 50Amp. 10.3kW (48.2Amp.)
Electrical Requirements
The above electrical specifications are for
reference only. See the range data plate
for exact specifications. See page 1 for
location.
[_ WARNING:
If the electric service provided
does not meet the product
specifications, do not proceed
with the installation. Call the
selling dealer or a licensed
electrician.
NOTE:
If the appliance is connected
to a 120/208 volt power supply,
preheat times and cavity
temperature recovery times will
be increased slightly.
Product Dimensions
60" (1524mm)long
240 Vac 4 wire
conduit location
Optional full
size side
!
35" '
!
(889mm)_
5/16"- 1 13/16"
(8- 46mm)
Removable (factory
3" (76mm) side panels
Dimensions - Isometric View
30"
(762mm)
Range top
Rear of control
Panel/oven door
Door opened
23 2"
(59 Im)
_.5._'16"
345 rim',
/
Max. depth
to oven door
handle with
door closed
45 1/4"
(1149mm)
1
Dimensions - Top View
_acar 2