Specifications

6
Installation Specifications
Install a Support Platform in the
Cabinet
Provide a platform (100 lb. load capacity) within the cabinet
upon which the warming drawer will be supported. The
platform must be installed level and straight. The top edge
of the platform must be flush with the cutout at the front of
the cabinet. There are no provisions to level the warming
drawer after it has been installed. 3/4” (19 mm) thick
plywood is recommended.
NOTE:
If the drawer is not installed in a level fashion, the
drawer may slide open on its own or may not seal
tightly, allowing heat to escape and resulting in poor
warming drawer performance.
Support
platform
Chas si s
face
The warming drawer is supplied with a power cord •
terminated by a three-prong plug. Plug it directly into a
dedicated, grounded, three prong, electrical outlet. Do
not use an extension cord.
The correct voltage, frequency and amperage must be •
supplied to the electrical outlet from a grounded, single
phase circuit that is protected by a properly sized circuit
breaker or time-delay fuse.
The required voltage, frequency and amperage ratings •
are listed on the appliance data plate. The data plate
is located inside the chassis drawer opening on the left
side. Remove the drawer to expose it.
If the power supply requirements shown above do not •
agree with those listed on the product data plate, use
the requirements on the product data plate.
It is the owner’s responsibility to ensure that the •
electrical outlet is installed by a qualified electrician.
The electrical installation must comply with the latest
revision of the National Electric Code ANSI/NFPA 70
and local codes and ordinances.
If the electrical service provided does not meet the •
product specification, or does not conform to the NEC
or local standards, do not proceed with the installation.
Call a licensed electrician to correct the electrical
service before proceeding.
Be certain to locate the electrical outlet in an •
accessible location, so that the warming drawer may
be easily unplugged in the event that service becomes
necessary.
Electrical Power Supply
Requirements
Nominal Electrical Supply Requirements
120 Vac, 60 Hz, 15 Amp. dedicated circuit
The warming drawer is supplied with a 40” (1016 mm)
power cord with a three prong grounded plug.
Total Connected Load 0.5 kW (4 Amp.)
Three-Prong Plug
Three-Prong
Grounded Outlet