Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor ® hood assembly or Dacor raised vent must be purchased separately. See the hood or raised vent installation instructions to determine suitability. Part No. 65265 Rev.
Important Safety Instructions .......................................... Important Information About Safety Instructions .............. Safety Symbols and Labels ............................................. General Safety Precautions ............................................. Product Specifications ..................................................... Product Dimensions ......................................................... Installation Planning and Preparation .............................
Important Information About Safety Instructions The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. • Always contact the Dacor Customer Service Team about problems and conditions that you don't understand. See Customer Service Information above.
General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using this blower, follow basic safety precautions, including the following: WARNING Do not install or 0perate this unit if ithas been dam, aged, dropped, has damaged electrical wiring or is not working properly.
Product Di mensions -_17 All tolerances: +1/16",-0, 19 (483mmj 3/8" (441mm)_ .__ 9 1/2" (241mm) 7 1/2" I-I '- h_ _ 5 13/16" (202mm) _1(148mm) (191mm)I- V 3 5/8" I ., --_ Power SupplyL,_" Conduit 7 15/16" I € (1.6 mm,0) unless otherwise noted. (92mm) -f 9 1/4" (235mm) Hole/_.. 8" Nom. (203mm) 24 1/4" (616mm) _! /s Intake 25 1/2" (648mm) Collar / Mounting Flange Intake Collar Discharge Discharge REMP3 .
Electrical Supply Requirements The power for this blower is supplied via 1/2" 3-wire wiring/conduit (not included) by an approved Dacor hood or raised vent. The wiring/conduit is installed between the hood or raised vent and the blower and Installation Planning System Layout WARNING shall be terminated on each end by a 1/2" UL certified strain relief. The power is turned on and off by the power switch on the approved ventilation device.
Blower Location and Mounting • Select a location that can properly support or can be reinforced to support the weight of the blower (see weight table below). The unit requires a mounting surface around the perimeter of the base of the unit 2" in width and thick enough to accommodate the 8, 2 1/2" long mounting screws that are provided with the unit. All contact surfaces between the blower and any mounting surfaces must be solid and at right angles. See Figure 1 for the required mounting surface dimensions.
, [_ • WARNING Remove the blower's top cover by removing the screws around the edge that hold it in place. If the electrical service provided does not meet the power requirements for the hood/raised vent and the blower combined, do not continue with the installation. Contact a licensed electrician to correct the situation before continuing. Failure to connect the wiring as specified may result in an electric shock hazard and/or improper blower operation.
Electrical Installation 7. , , Run the wiring used to supply power from the installed raised vent or hood to the blower parallel to the duct work. 12. Connect the white (neutral) wire to the N2 blower power terminal (see Figure 9). Tighten the terminal screw firmly into place. IMPORTANT: The neutral (N2) terminal on the blower has the BLACK wire from the blower wiring harness connected to it.
REMPSeries Blower Ratings Model Number Nominal Rating* Actual Rating* REMP3 600 CFM 620.5 CFM REMP16 1000 CFM 994.8 CFM At 0" static pressure REMP3 Blower Performance REMP16 Blower Performance _- 5.0 _- 2.5 .4--, (5 --o 4.0 _2.0 o (/) 09 ..C r- =o1.5 c° 3.0 i _if? 2.o 1.0 u) Q. o 1.0 o 0.5 .+._, (u _J 4--.
4# The Life of the Kitchen? Dacor • 1440 Bridge Gate Drive, Diamond Bar, CA 91765 • Tel: (800) 793-0093 • FAX: (626) 403-3130 • www.Dacor.