Product specifications

,
[_ WARNING
If the electrical service provided does not meet the
power requirements for the hood/raised vent and the
blower combined, do not continue with the instal-
lation. Contact a licensed electrician to correct the
situation before continuing.
Failure to connect the wiring as specified may result
in an electric shock hazard and/or improper blower
operation.
To avoid the risk of fire or electric shock, turn off
power at the circuit breaker panel or fuse box before
connecting the blower to the power source.
The blower assembly is heavy. Do not attempt to lift
or move it without assistance.
Parts List
Verify Package Contents
2 1/2" wood mounting screws (8)
Blower assembly
Parts Required
3 conductor wiring/conduit with UL certified strain relief
on each end (length is determined by remote blower
location).
If the blower will be mounted to a surface other than
wood, fasteners designed for the material the unit will
be mounted to must be provided. The fasteners must
be capable of supporting the weight of the blower (see
weight table on page 5) and meet local codes and ordi-
nances.
Consult the hood or raised vent installation instructions
for additional part requirements.
Installation
,
Before installing the blower, unpack the unit and check
for physical damage to the motor and blower assembly.
To do so, reach in through the intake collar and spin
the fan blades slowly. They should spin freely and qui-
etl_ without vibration.
Figure 5
O
Intake
Collar
o__ Fan
Blades
Bottom of Blower
O
,
,
,
,
Remove the blower's top cover by removing the screws
around the edge that hold it in place.
Figure 6
Apply sealant between the blower and the mounting
surface where the flange around the edge of the blower
will rest.
Flange
Sealant
45 °Adjustable
Elbow
Roof
Round Duct
Figure 7
Pick up the blower assembly and center it on the
mounting surface inserting the intake collar into the
cutout.
While holding the blower in place, fasten it to the
mounting surface with eight (8) mounting screws. The
mounting holes are located inside the blower assembly
chassis near the sides.
Install the duct work according to the installation
instructions for the hood or raised vent. Support the
duct weight as necessary to ensure properly sealed
joints.
6 _mC_