Installation instructions

19
Installation Instructions
Four (4) corners are bent backward 90 degrees.
Using the Dual to Single
Transition Kit# AHT10
On dual exhaust models, the two 8-inch duct exhausts can
be transitioned into one 10-inch duct.
Assemble the Dacor transition kit # AHT10 before hanging
the hood. This transition kit fits over the top or rear ventila-
tion exits.
Preparing the AHT10
1. Create a lip around the transition kit by bending the
bottom edges backward at right angles to create a 3/4”
flange around the base.
IMPORTANT: Rear vent, 12-inch tall hood configurations,
keep one of the long edges straight.
12-inch tall hoods are models: 3012, 3612, 4812
Bending the Flange for:
Top Vent Configuration: None. Rear Only
Rear Vent Configuration
On models 3012, 3612, 4812
Notes: 12” hood height requirement
Keep one of the long edges straight!
One (1) edge remains straight and unbent.
12-inch
height
Bending the Flange for:
Top Vent Configuration: 3012, 3612, 4812
3018, 3618, 4818
Rear Vent Configuration
On Models: 3018, 3618, 4818
Notes: 18” hood height requirement
• If your hood model ends in “12” see above
18-inch
height
32”
(81.3 cm)
13 3/4
(34.9 cm)
3/4”
(1.9 cm)
9”
(22.9 cm)
2” (5.1 cm)
Leave a long edge
straight and unbent.
This lip will act as a
bracket.