Installation Instructions
18
Make sure dimmable bulbs are used. The electronic board
is designed for dimmable light bulbs and using non-dimma-
ble types will cause damage and faulty performance.
Shut the main circuit breaker OFF while inserting new
bulbs or while changing bulbs. If an electrical short occurs
while the main power circuit is ON, significant damage can
occur.
Follow the diagram to the right.
1. Insert a bulb into one of the light sockets.
2. Attach the suction cup to the lens of a dimmable light
bulb. (Both are supplied parts.)
Make sure the bulbs are clean and dry so the
suction cup will stick.
3. Screw it into place and remove the suction cup.
4. Repeat for the remaining light fixtures.
5. Switch the main circuit power ON.
Replacement Part
Number
Replacement Kit
Description
702666
Dimmable LED 7.5W
(1 bulb + 1 suction cup)
700975
Halogen Bulb 75W
(1 bulb + 1 suction cup)
TIP: Replace all bulbs when changing from LED to
Halogen because of the difference in light color.
Installation Instructions
Inserting Dimmable Light Bulbs
Size: PAR16, E26/27
75 Watt max., 60 Amp
Inserting Light Bulbs with the
Suction Cup Tool
2
1
Verifying the Setup
Verify the setup to ensure everything functions correctly:
1. Turn the power ON at the circuit panel or fuse box.
2. Assemble the filters if not already done so.
3. Insert the filters gently:
Be careful not to scratch the back of the grease
channel!
• Raise the front edge into the tension clip, and press
forward.
• Lift the rear edge up and above the grease channel.
Use caution not to scratch the filter against the grease
channel or scratch other parts of the unit or filters.
• Set the rear edge onto the grease channel.
4. Turn the LIGHTS knob. Twist the knob half-way around
for the lights to illuminate.
5. Turn the LIGHTS knob in the opposite direction to turn
the lights off.
6. Turn the FAN knob. The fan(s) will start at maximum
speed and decrease as you continue.
7. Turn the FAN knob in the opposite direction to turn the
fan(s) off.
If the RNIVS Fails to Function Correctly:
1. Verify that power is supplied to the RNIVS via the out-
let, circuit breaker, or another main power source.
2. Make sure the electrical supply has not been disrupted
by a blown fuse or problems in the outlet or service.
3. Check the electrical connections to ensure that the
wiring installation has been completed correctly.
4. Repeat the above steps.
• If the RNIVS still does not work, contact Dacor
Customer Assurance: 833-35-ELITE (833-353-5483).
• Do not attempt to repair the appliance yourself.
• Dacor is not responsible for service required to correct
a faulty installation.
FAN
knob
LIGHTS
knob
Control Panel