Installation Instructions Heritage Integrated Ventilation System RNIVS1, RNIVS2, RNIVSR1, RNIVSR2 ® APPROVED FOR USE WITH ALL DACOR RANGES AND COOKTOPS. TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507 STANDARD FOR ELECTRIC FANS AND CAN/CSA-C22.2 NO. 115 STANDARD FOR FANS AND VENTILATORS. Part No. 113919 Rev.
Table of Contents Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 2 General Safety Precautions.............................................. 3 Product Specifications ..................................................... 5 General Specifications...................................................... 5 Dimensions....................................................................... 8 Preparation and Setup................
Important Safety Instructions Important Information • The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining, or operating this or any other appliance. • Always contact Dacor Customer Assurance about issues you cannot resolve.
Product Specifications General Specifications Dacor’s Heritage Integrated Ventilation System (RNIVS) is designed to be installed inside custom hood canopies. Correct installation requires that the custom canopy be constructed with precision design, manufacturing, and materials. Follow all instructions and warnings concerning the installation of the RNIVS within a combustible or non-combustible hood canopy. Make sure that all construction meets applicable local codes and regulations.
Product Specifications Product Dimensions All tolerances are ±1/16” (±0.16 cm) RNIVS1 & RNIVSR1 8 7/8” (22.5 cm) 3/8” (1.0 cm) 20 1/4” 21 7/16” 3/8” Rear Flange Extension 18 1/2” (54.43 cm) (46.92 cm) (54.45 cm) 19 5/8” (49.82 cm) RNIVS1 & RNIVSR1 Dimensions 10 23/32” Top View (27.69 cm) CL 10 23/32” (27.69 cm) CL 5 3/4” (14.54 cm) Top Centerline Dimensions 3 6 3/16” (15.
Product Specifications Product Dimensions All tolerances are ±1/16” (±0.16 cm) RNIVS1 & RNIVSR1 Rear View 3/8” (1.0 cm) cha back panel nne l de pth channel height 2 1/8” (5.04 cm) Channel Dimensions Side View .40 3/8” (1.0 cm) flange 3/8” Rear Flange Extension channel depth 3/8” (1.0 cm) channel height 2 1/8” Detail (5.04 cm) flange 3/8” flange extension length (1.
Product Specifications Product Dimensions All tolerances are ±1/16” (±0.16 cm) RNIVS2 & RNIVSR2 8 7/8” (22.5 cm) 3/8” (1.0 cm) 30 1/4” (76.84 cm) 18 1/2” (46.92 cm) 31 7/16” (79.83 cm) 3/8” Rear Flange Extension 19 5/8” (49.82 cm) RNIVS2 & RNIVSR2 Dimensions Top View 6” (15.24 cm) CL CL 6” (15.24 cm) 6 3/16” (15.72 cm) 5 3/4” (14.
Product Specifications Product Dimensions All tolerances are ±1/16” (±0.16 cm) RNIVS2 & RNIVSR2 Rear View 3/8” (1.0 cm) cha back panel nne l de pth channel height 2 1/8” (5.04 cm) Side View Channel Dimensions .40 flange 3/8” Rear Flange Extension 3/8” (1.0 cm) 3/8” (1.0 cm) channel depth Detail channel height 2 1/8” (5.04 cm) flange 3/8” flange extension length (1.
Preparation and Setup Parts List A RNIVS Features RNIVS1 RNIVS2 C Filters 2 3 E LED Lights 2 2 B Grease channel (1) pictures vary by model C Baffle filter and hardware (2) A E Dimmable LED light bulbs (2) F Light replacement tool (1) B G Literature (2) C H Dacor Stainless Cleaning Creme (1) H E STAINLESS STEEL CLEANER G F Necessary Tools and Hardware Optional Accessories Please make sure these tools and hardware are within reach before beginning the installation.
Preparation and Setup Meeting Installation Requirements WARNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Use only ductwork deemed acceptable by state, municipal and local codes. E WARNING To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the range should be avoided.
Preparation and Setup Meeting Electrical Codes WARNING Make sure electrical service to the RNIVS is installed by a licensed electrician. It is the owner’s responsibility to confirm that all electrical requirements are met by a qualified electrician who is servicing this appliance. A B The electrical installation, including the minimum supplywire size and grounding, must be in accordance with the National Electric code ANSI/NFPA* (or latest revision), local codes, and ordinances.
Preparation and Setup Planning the Ductwork WARNING • • • • To prevent combustion by-products, smoke or odors from entering the home and to improve efficiency, tape all duct joints securely. Range hoods may interrupt the proper flow of smoke and combustion gases from furnaces, gas water heaters, and fireplaces. To avoid drawing lethal gases into the home, follow the manufacturer’s recommendation for these devices and consult NFPA and ASHRAE recommendations.
Installation Instructions Assembling the Filters Filters are boxed separately and must be assembled during installation. All knobs and hardware are included with the filters. To ensure the correct orientation, make sure the top of the filter lays face-up. The face of the filter has: • plastic peel-away coating • a beveled lip on the inside frame • screw holes up on the ridge (not down in the trough) Instructions 1. Remove the plastic coating and confirm that the inside lip is beveled.
Installation Instructions Installing the Hood Liner Kit #RNIHL The Heritage Integrated Hood Liner (RNIHL) is available separately and must be installed before the RNIVS. The RNIHL liners are made from of durable, noncombustible stainless steel. The latest Renaissance® design make it an excellent component for any custom hood.
Installation Instructions Attaching the Dual-to-Single Transition Kit #ATD10 Two 8” ducts can be transitioned into one 10” duct. • Attach the kit # ATD10 before installing the RNIVS. • The kit fits over the top ventilation exits. 10 inch round Marking the Centerlines All tolerances are ±1/16” (±0.16 cm) This procedure is for centering the RNIVS and marking the duct cutouts. Have a marking tool and tape measure ready. 1.
Installation Instructions Installing the RNIVS WARNING Installing the RNIVS requires two people. Do not attempt to lift and hold the RNIVS without assistance. Wear protective gloves while holding the unit. Sharp edges can cause injury to hands and fingers. NOTE: If using a liner kit with the RNIVS, please follow the instructions on page 13. NOTE: If using the RNIVS without a liner kit, use a 3/8” spacer. See the next page. When hanging the RNIVS, be careful not to scratch or damage the unit. T 1.
Installation Instructions Adding a Spacer If using the RNIVS without a liner kit, use a 3/8” spacer: 3/8” (1.0 cm) depth The flange circling the bottom of the unit will not allow the unit to lay flat against a wall. Therefore, use a 3/8” spacer behind the rear mounting holes to ensure that the unit lays flush against the wall or canopy. bac kc han nel 2 1/8” height (5.04 cm) See images below that illustrate the 3/8” flange extension that prevents the unit from being flush against a wall.
Installation Instructions Hardwiring the Hood WARNING • To avoid electric shock or fire hazard, make sure that power to the RNIVS power supply line is turned OFF at the fuse box or circuit breaker before connecting the electrical wiring. • Miswiring the RNIVS electrical wiring can create an electric shock or fire hazard and could damage the RNIVS’ electrical system. See page 25-26. • Do not ground the wires to the neutral (white) wire.
Installation Instructions Grounding to a Cold-Water Pipe WARNING • Do not ground the circuit to a gas line. • Do not ground the circuit to a hot water pipe. • Water lines that are insulated must be jumped to assure continuity to ground. See below. Meter No. 4 copper wire To ground the RNIVS to a cold water pipe, refer to the images on this page. Clamps Bare metal Metal Cold Water Pipe (detail) To house circuit breaker or fuse box Wire nut, 3 places Separate No.
Installation Instructions Inserting Dimmable Light Bulbs Size: PAR16, E26/27 75 Watt max., 60 Amp Verifying the Setup Make sure dimmable bulbs are used. The electronic board is designed for dimmable light bulbs and using non-dimmable types will cause damage and faulty performance. Shut the main circuit breaker OFF while inserting new bulbs or while changing bulbs. If an electrical short occurs while the main power circuit is ON, significant damage can occur. Follow the diagram to the right. 1.
Installation Instructions BACK The Installation Checklist WARNING tens ion c lip • To ensure a safe and correct installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked. • Proper installation is the responsibility of the homeowner. The importance of proper installation of your Dacor range RNIVS cannot be overemphasized.
Wiring Diagrams RNIVS1 & RNIVSR1 CONNECT TO 120V 60Hz 15A POWER SUPPLY G W WIRING DIAGRAM HOOD HOOD LIGHT 75W LIGHT 75W RNIVS1, RNIVSR1 B RNIVSR1 DOES NOT HAVE A FAN IN THE UNIT; IT IS FOR A REMOTE BLOWER ONLY W LAMP DIMMER B LIGHT B LIGHT B FAN B FAN FOR CONNECTION TO ARLC/ARSC /ARSLC FAN SWITCH B G W FAN MOTOR B W G DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
Wiring Diagrams RNIVS2 & RNIVSR2 CONNECT TO 120V 60Hz 15A POWER SUPPLY G W WIRING DIAGRAM HOOD HOOD LIGHT 75W LIGHT 75W RNIVS2, RNIVSR2 RNIVSR2 DOES NOT HAVE A FAN IN THE UNIT; IT IS FOR A REMOTE BLOWER ONLY B W LAMP DIMMER B LIGHT B LIGHT B FAN B FAN FOR CONNECTION TO ARLC/ARSC /ARSLC FAN SWITCH B G W B FAN MOTOR B W G CAUTION: DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT.
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.