Installation Instructions Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Part No. 65278 Rev.
Table of Contents Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 1 General Safety Precautions.............................................. 2 Product Specifications...................................................... 3 General Specifications...................................................... 3 Product Dimensions.......................................................... 3 Installation Requirements.................
Important Safety Instructions Safety Symbols and Labels Important Information About Safety Instructions • DANGER The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. • Always contact the Dacor Customer Service Team about problems and conditions that you do not understand.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following: WARNING • Do not install or operate this appliance if it has been damaged, dropped, has damaged electrical wires or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
Product Specifications General Specifications Filters Mesh type, dishwasher safe Lights 120 Vac, 75 Watt, halogen Total Circuit Requirements* 120 Vac, 60 Hz., 15 Amp. Min. grounded , dedicated circuit IVS1: 0.2 kW (2 Amp.) IVS2: 0.4 kW (3 Amp.) Total Connected IVSR1/IVSR2 0.2 kW (1.5 Amp.) plus Load* the power requirements of the in-line or remote blower connected. Blower Rating** The Dacor Integrated Ventilation System (IVS) is designed for installation inside custom hood canopies.
Installation Requirements WARNING To reduce the risk of fire, all stated minimum clearances must be met or exceeded. • Local building codes may require the use of makeup air systems with ventilation systems that move air greater than the specified movement rate (CFM). The specified rate varies based on locale. Consult a qualified HVAC specialist when designing the system for the requirements in your area and to assure optimal performance.
Installation Requirements • To prevent back-drafts, a damper at the duct outlet may also be required. The IVS comes equipped with a backdraft damper installed in the collar of the unit. • Make sure duct work does not interfere with floor joists or wall studs. • The hood exhaust connects to a 8-inch round duct. You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run.
Installation Instructions Installing the IVS Electrical Connection WARNING WARNING To avoid an electric shock hazard, do not connect the wiring harness until after the IVS is installed in the cutout and the duct work is installed. 1. If installing a hood liner (Dacor series IHL) install it before installing the IVS. 2. Remove the filters from the IVS. 3. The IVS comes pre-wired from the factory. Insert the unit into the cutout while routing the wiring harness to the junction box. 4.
Installation Instructions Verifying Proper Operation 1. Install the filters. 2. Install the light bulbs. • Attach the included suction cup to one of the provided light bulbs. • Insert it into one of the light fixtures. • Screw it into place and remove the section cup. • Repeat for the remaining light fixtures.
Wiring Diagrams GROUND NEUTRAL LINE WH BLK HALOGEN LIGHTS (2) WH BLK LAMP DIMMER BLK FAN MOTOR WH BLK FAN SWITCH M IVS1, IVSR1 GROUND NEUTRAL LINE WH BLK LAMP DIMMER BLK WH BLK BLK HALOGEN LIGHTS (3) WH BLK FAN MOTORS M M IVS2, IVSR2 8 FAN SWITCH
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.