Insert Liner Installation
5
Verifying the Correct Setup
See the RNIVS Installation Instructions, and follow the
steps in Verifying the Correct Setup.
NOTE: If the blower or lights do not function correctly,
follow these troubleshooting steps:
1. Verify that power is being supplied to the RNIVS.
2. Verify the electrical connections are wired correctly.
3. If the unit still does not work, contact Dacor Customer
Assurance:
833-353-5483.
Do not attempt to repair the unit yourself. Have the
model and serial numbers available when you call.
Dacor is not financially responsible for correcting
issues due to faulty installation.
Correct Placement & Setup
1. Feed the electrical wires through the hood liner
opening (see the previous graphic).
2. Push the RNIVS through opening of the RNIHL until it
stops.
3. Attach the RNIVS to the RNIHL using all the lock
washers and bolts (see images at right). This hardware
is provided.
4. The installed RNIVS will sit atop the RNIHL. The
assembled parts will look like the image on the right.
Make sure the RNIHL is securely fastened to the hood
canopy. The RNIHL will hold the weight of the RNIVS.
The hood liner must be secured inside the hood canopy
and ready for the ventilation system to be attached.
Refer to the image below while installing the ventilation
system.
To Install the RNIVS:
Installation Instructions
RNIHL RNIVS
RNIVS Installed on an RNIHL
lock washers
bolts
Installing the RNIVS (Ventilation
System)