4.5 How to set Temperature Alarm Value
ཛ Press the SET button for 3 seconds until the TEMP_HI and TEMP_LO LED flash
simultaneously which showing current te mperature alarm values of SENSOR ID 1.
ཛྷ To set the temperature high alarm value, press the UP and DN button of TEMP_HI
field. The temperature high alar m value increases or decreases in 1Ȕ interval ranging
between -40Ȕ to 120Ȕ.
ཝ To set the temperature low alarm value, press the UP and DN button of TEMP_LO
field. The te mperature low ala rm value increases or decreases in 1Ȕ interval ranging
between -40Ȕ to 120Ȕ.
ཞ Whenever pressing t he SET button, the next SENSOR ID and TEMP_HI and
TEMP_LO values are displayed in sequence.
ཟ When you complete the alarm setting, press the ALARM button. The LED stop
flashing and current temperature and humidity value are displayed.
D
D
The TEMP_HI value should be higher than TEMP_LO value. If not, abnormal
temperature alarm operation may occur.
<Figure 13> How to set Temperature Alarm Value of Base Monitoring Unit