Owner's Manual

20
roblem
Possible Cause
Probable Correction
The machine
doesn't operate
The ice maker is unplugged.
Plug the ice maker in.
The fuse is blown.
Replace fuse--if it happen, call for service to
check for a short circuit in the ice maker.
The ice maker power switch
is OFF.
Turn the ice maker power switch to ON
The ice storage bin is full of
ice.
Take away some ice, make the ice-full sensor
is free of ice.
The water
doesn't feed in
after the ice
maker starts.
The water supply tap is turn
off.
Turn on the water supply tap.
The water supply pipe is not
proper connected.
Reconnect the water supply pipe.
Machine makes
ice, but bin
does not fill up
with ice
The condenser may be dirty.
Clean the condenser.
The air flow to the ice
maker may be obstructed.
Check the installation.
The ambient temperature
and water temperature are
high, or it is near with some
heat resource.
Check the installation.
Water is leaking
out the unit.
A few water drops to the
floor when you open the
door to take out ice from ice
storage bin.
Normal condensation on the door or some
water together with ice. Take care when you
take out ice.
Water supply connection
leaks.
Tighten fitting. See Connecting the water line.
Cubes are
partially
formed--are
white at the
bottom.
Not enough water in the
water bin.
Check if the water supply pressure is below
15psig.
Check water supply--filter may be restricted.
Check for a water leak at the water tank.
Noise during
operation
The feet are not leveled.
See Leveling the Ice Maker.
Certain sounds are normal.
See Normal Sounds.
The icemaker
stops suddenly
while making
ice.
The electricity is off.
Reconnected the power supply line.
The room temperature is out
the state range.
Cut off the electricity, let the ice maker stop
working till the temperature returns within the
stated range.
The body of the
ice maker is
electrified
The earth line isn't in the
socket.
Please use the socket meeting the standard.
Scales occur
frequently
inside the
machine.
The hardness of the water
quality is too high.
Using a water-soften apparatus installed in
front of the water inlet.
The ice cubes
are not
completely
formed when
being dumped.
The sprinkler is blocked.
Clean the sprinkler, see "interior cleaning"