1. How to start
1) Under “LOCK” mode, press “SUPER FREEZER” button 5 times while pressing
“FREEZER SET” button at the same time.
2) The front CLED displays as the right diagram shows
( [Ex.] Time Display of 0003 signifies 3 minutes of power on time.)
3) Press “FREEZER SET” button and the following value is displayed successively.
Time
F-Sensor temperature
D-Sensor temperature
R-Sensor temperature
RT-Sensor temperature
P Factor display (Refer to water supply mode of automatic icemaker)
Filter remaining time until change (First check ; 4,320Hr)
Refer to Filter Information Reset of CLED of front control panel.
4) Error is displayed only if there is any ; it is skipped if no error.
2. How to stop
1) Push “LOCK” button 1 time.
2) It stops automatically in 4 minutes from the start.
3. All the error Codes are reset if they turn to be normal.
4. Error code
INPUT CONTROL OBJECT
CONTENTS REMARKS
Temperature Control Buttons 88 Display CLED
Display forced defrost mode for A/SD2
Display Full Down modeCo
Return after defrosting : abnormal or defectiveF3
Cycle : abnormal or defectiveC1
Full ice switch : errorEu
Drop the ice while EtEA
Micro switch : errorES
Water supply : errorEg
Horizontal switch : errorEt
Flow sensor : defectiveEF
I-sensor : disconnection (“Lo”), short (“Hi”)EI
Home bar Door Switch : defectivedH
F-Door Switch : defectivedF
R-Door Switch : defectivedr
D-sensor : disconnection (“Lo”), short (“Hi”)d1
RT-sensor : disconnection (“Lo”), short (“Hi”)rt
R-sensor : disconnection (“Lo”), short (“Hi”)r1
F-sensor : disconnection (“Lo”), short (“Hi”)F1
CONTENTSERROR CODE