User's Manual

R&D / Automotive Electronics
Title Remote Keyless Entry System Specification Spec. No. DPE-AE-RK019912S
Written by Ban Dong Hoon
Rev. No.
A0
Date 10
th
. Nov. 2003 Page
17 / 25
5. SYSTEM INPUT/OUTPUT CIRCUIT
5.1.1 SERIAL DATA LINK(NO. A17)
It is the line for communicate receiver and diagnostic device. It defines RKE diagnostic protocol
regulation(#DPE-AE-RK509603S)
5.1.2 ELECTRIC OUTPUT
5.1.2.1 HAZARD LAMP (LEFT : A26, RIGHT : A13)
- Type : Normal open Relay
(V23072-C1061-A408)
- Output Level : Battery voltage to GND
- Max. switching current : 2 x 60 A
- Max. continuous current : 2 x 10 A @ +23
- Fault Diagnostic Request : No
- State During Reset : Off
- Short Circuit Protection Request : No
- Over Current Protection Request : No
- RIGHT LOAD : 21W x 2EA, 5W x 1EA
- LEFT LOAD : 21W x 2EA, 5W x 1EA
5.1.2.2 SECURITY INDICATOR(A19)
- Type : Low Side Drive
- Output Level : 1V to GND
- Max. Output Current : 100mA
- Min./Max. Duty Cycle : 0 / 100 %
- Fault Diagnostic Request : No
- State During Reset : Off
- Short Circuit Protection Request : No
- Over Current Protection Request : Yes
5.1.2.3 LOCK(A10)
- Type : Low Side Drive
- Max. Low Output Level : 1V to GND
- Max. Output Current : 500mA
- Fault Diagnostic Request : No
- State During Reset : Off
- Short Circuit Protection Request : Yes
- Over Current Protection Request : Yes
5.1.2.4 UNLOCK(A11)
- Type : Low Side Drive