CE CONFORMANCE VERIFICATION NOT TRANSFERABLE CE CONFORMANCE VERIFICATION is hereby issued to the named Applicant, and is VALID ONLY for the equipment identified hereon for use under the rules and regulations listed below: Applicant's Name: Applicant's Address: Manufacturer's Name: Manufacturer's Address: Type of Equipment: Model Number: Serial Number: Applicable Regulation: DAEWOO ENERTEC Co., Ltd.
LVD TEST REPORT Report Number : KSQ-LVD081010 CE CONFORMANCE TEST REPORT LOW VOLTAGE DIRECTIVE 2006/95/EC EN60335-1:1994+A1/+A2/+A11/+A12/+A13/+A14/+A15/+A16 EN60335-2-45:2002 for DAEWOO ENERTEC Co., Ltd.
LVD TEST REPORT Report Number : KSQ-LVD081010 1. General Information 1.1 Introduction The LVD Test Report for CE Declaration of Conformity is prepared on behalf of named applicant in accordance with the Low Voltage Directive (2006/95/EC) of the European Economic Community. The test results reported in this document relate only to the item that was tested.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test Result - Remark Copy of Marking Plate Page 4 / 63 Verdict
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test 5 GENERAL CONDITIONS FOR THE TESTS Tests performed according to cl. 5, e.g. nature of supply, sequence of testing, etc. CLASSIFICATION Protection against electric shock: Class I, II Protection against harmful ingress of water Insect killer intended for outdoor use is at least IPX4 MARKING AND INSTRUCTIONS Rated voltage or voltage range (V)..........................: Nature of supply....................................................
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 7.5 7.6 7.7 7.8 7.9 7.10 7.11 7.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 7.12.1 7.12.2 7.12.3 7.12.4 7.12.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test 7.13 7.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 8.1.2 8.1.3 8.1.4 8.1.5 8.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test 10 POWER INPUT AND CURRENT Power input at normal operating temperature, rated (see appended table) voltage and normal operation not deviating from rated power input by more than shown in table 1 Current at normal operating temperature, rated (see appended table) voltage and normal operation not deviating from rated current by more than shown in table 2 HEATING Marked with hot surface No excessive temperatures in normal use warning ma
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 13.2 13.3 14 15 15.1 15.1.1 15.1.2 Requirement - Test Result - Remark Motor-operated appliances and combined appliances supplied at 1.06 times rated voltage.....
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 15.2 15.3 16 16.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 16.2 16.3 17 18 19 19.1 19.2 19.3 Requirement - Test Result - Remark Protective impedance disconnected from live parts No protective impedance before carrying out the tests Single-phase appliances: test voltage 1.06 times 220V x 1.06 = 233.2V rated voltage...........................................................: Three-phase appliances: test voltage 1.06 times rated voltage divided by √3......................................
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 19.4 19.5 19.6 19.7 19.8 19.9 Requirement - Test Result - Remark Test conditions as in cl. 11, any control limiting the temperature during tests of cl. 11 short-circuited Test of 19.4 repeated on Class 0I and I appliances with tubular sheathed or embedded heating No tubular sheathed or embedded heating elements elements.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 19.10 19.11 19.11.1 19.11.2 19.11.3 Requirement - Test Result - Remark Winding temperatures not exceeding values as (see appended table) specified Series motor operated at 1.3 times rated voltage for No series motor 1 min........................................................................: During the test, parts not being ejected from the appliance Electronic circuits, compliance checked by evaluation of the fault conditions specified in 19.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 19.12 19.13 20 Requirement - Test Result - Remark During and after each test the following is checked: - the temperature rise of the windings do not exceed Complies the values specified in table 8 - the appliance complies with the conditions Complies specified in 19.13 - any current flowing through protective impedance No protective impedance not exceeding the limits specified in 8.1.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test 20.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 22.3 22.4 22.5 22.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 22.10 22.11 22.12 22.13 22.14 22.15 22.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 22.17 22.18 22.19 22.20 22.21 22.22 22.23 22.24 22.25 22.26 22.27 22.28 22.29 22.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 22.31 22.32 22.33 22.34 22.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 22.36 22.37 22.38 22.39 22.40 22.41 22.42 22.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 22.44 22.45 23 23.1 23.2 23.3 Requirement - Test Result - Remark Appliances are not allowed to have an enclosure that is shaped and decorated so that the appliance is likely to be treated as a toy by children When air is used as reinforced insulation, clearances not reduced below the values specified in 29.1.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 23.4 23.5 23.6 23.7 23.8 23.9 24 24.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 24.1.1 24.1.2 24.1.3 24.1.4 24.1.5 24.1.6 24.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 24.3 24.4 24.5 24.6 25 25.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 25.2 25.3 25.4 25.5 25.6 25.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 25.8 25.9 25.10 25.11 25.12 25.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 25.14 25.15 25.16 Requirement - Test Result - Remark Supply cords adequately protected against Not moved while in operation excessive flexing Flexing test: - applied force (N)...................................................: See above - number of flexings...............................................
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 25.17 25.18 25.19 25.20 25.21 Requirement - Test Result - Remark - the cord is not clamped by a metal screw which bears directly on the cord - at least one part of the cord anchorage securely fixed to the appliance, unless part of a specially prepared cord - screws which have to be operated when replacing the cord do not fix any other component, if applicable - if labyrinths can be bypassed the test of 25.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 25.22 25.23 25.24 25.25 26 26.1 26.2 Requirement - Test Result - Remark Appliance inlet: - live parts not accessible during insertion or removal - connector can be inserted without difficulty - the appliance is not supported by the connector - is not for cold conditions if temp.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 26.3 26.4 26.5 26.6 26.7 26.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 26.9 26.10 26.11 27 27.1 27.2 27.3 27.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 27.5 27.6 28 28.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 28.2 28.3 28.4 Requirement - Test Result - Remark Screws used for electrical connections or connections providing earthing continuity screw into Screw used for earth connection.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test 29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION Clearances, creepage distances and solid insulation withstand electrical stress For coatings used on printed circuits boards to protect the microenvironment or to provide basic insulation, annex J applies Clearances not less than the values specified in table 16, taking into account the rated impulse voltage for the overvoltage categories of table 15 The values specified may be s
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 29.1.5 29.2 29.2.1 Requirement - Test Result - Remark Clearance between surfaces of PTC heating elements may be reduced to 1mm Lacquered conductors of windings assumed to be bare conductors, but the clearances specified in table 16 are reduced by 0.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 29.2.2 29.2.3 29.2.4 29.3 30 30.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 30.2 30.2.1 30.2.2 30.2.3 30.2.3.1 30.2.3.2 Requirement - Test Result - Remark External parts: at 40 °C plus the maximum temperature rise determined during the test of clause 11, or at 75 °C, whichever is the higher; temperature (°C)....................................................
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 30.2.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 3.1.9 3.6.2 5.101 7.1 7.12 7.15 8.2 11.7 19.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 19.101 19.102 19.103 21.101 22.3 25.13 30.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 5 8 8.2 8.4 8.5 10 F 1.5 1.5.3 1.5.4 1.6 3.4 3.4.3.2 4.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test 4.2 4.2.1 4.2.5 4.2.5.2 Electrical tests This subclause is applicable This subclause is applicable Only table IX is applicable Values for test A apply However, for capacitors in heating appliances the values for test B or C apply Damp heat, steady state This subclause is applicable Only insulation resistance and voltage proof are checked Impulse voltage This subclause is applicable Endurance Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 22 29 29.1 and 29.2 H 8 13 15 15.1 15.2 15.3 17 Requirement - Test Result - Remark Fail-safe transformers comply with subclause 15.5 of IEC 61558-1 Construction Subclauses 19.1 and 19.1.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 20 I 8 8.1 11 11.3 11.8 16 16.3 19 19.1 19.101 Requirement - Test Result - Remark Subclause 17.2.5.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 22 22.101 J 6.6 6.6.1 6.6.3 6.8.6 6.9 K Requirement - Test Result - Remark Only one fault simulated at a time, the tests carried out consecutively Construction For class I appliances incorporating a motor supplied by a rectifier circuit, the d.c.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause L M Requirement - Test Result - Remark Equipment of overvoltage category III is equipment in fixed installations and for cases where the reliability and the availability of the equipment is subject to special requirements Equipment of overvoltage category II is energy consuming equipment to be supplied from the fixed installation If such equipment is subjected to special requirements with regard to reliability and availability, overvoltage category I
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause N 5 5.1 5.4 6 6.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test Result - Remark 10.1 TABLE: Power input deviation Input deviation of/at: P rated (W) 220V 60Hz 110V 60Hz 220V 50Hz 110V 50Hz 100 100 100 100 10.2 TABLE: Current deviation Current deviation of/at: I rated (A) 11.8 P measured (W) 95 97 98 96 I measured (A) TABLE: Heating test, thermocouples Test voltage (V).......................................................: Ambient (°C)........................................................
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test 11.8 TABLE: Heating test, resistance method Test voltage (V).......................................................: Ambient, t1 (°C).........................................................: Ambient, t2 (°C).........................................................: Temperature rise of winding Result - Remark R1 (Ω) R2 (Ω) dT (K) TABLE: Leakage current Heating appliances: 1.15 x rated input..................
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test Result - Remark TABLE: Leakage current Single phase appliances: 1.06 x rated voltage.....: Three phase appliances 1.06 x rated voltage divided by √3:.........................................................
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 17 Requirement - Test Result - Remark Verdict Overload Protection Temperature Test P Overload Protection Temperature Test Rated Voltage ······················································· - - Rated Supply Frequency ········································ - - t1 ··········································································· - - t2 ··········································································· - - Certified c
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test Result - Remark 19.7 TABLE: Abnormal operation, locked rotor/moving parts Verdict N Model/Type of Power Supply: Manufacturer of Power Supply: Rated Marking of Power Supply: Abnormal Tests Conducted at: Certified components and modules are used in accordance with their ratings, certifications and they comply with applicable parts of this Standard. No. Component Name Fault (S/O) Fuse No.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test Result - Remark TABLE: Abnormal operation, running overload Test voltage (V).......................................................: Ambient, t1 (°C).........................................................: Ambient, t2 (°C).........................................................: R2 (Ω) Temperature of winding R1 (Ω) Verdict 19.9 dT (K) T (°C) TABLE: Abnormal operation, temperature rises 19.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause 29.1 Requirement - Test Result - Remark TABLE: Clearances Overvoltage category.... : II Verdict P - Type of insulation: Rated impulse voltage (V): Min.
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test Result - Remark >400 and ≤500 >400 and ≤500 >400 and ≤500 >500 and ≤800 >500 and ≤800 >500 and ≤800 >800 and ≤1000 >800 and ≤1000 >800 and ≤1000 >1000 and ≤1250 >1000 and ≤1250 >1000 and ≤1250 >1250 and ≤1600 >1250 and ≤1600 >1250 and ≤1600 >1600 and ≤2000 >1600 and ≤2000 >1600 and ≤2000 >2000 and ≤2500 >2000 and ≤2500 >2000 and ≤2500 >2500 and ≤3200 >2500 and ≤3200 >2500 and ≤3200 >3200 and ≤4000 >3200 and ≤4000 >3200 and ≤4000 Ver
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test Result - Remark >4000 and ≤5000 >4000 and ≤5000 >4000 and ≤5000 >5000 and ≤6300 >5000 and ≤6300 >5000 and ≤6300 >6300 and ≤8000 >6300 and ≤8000 >6300 and ≤8000 >8000 and ≤10000 >8000 and ≤10000 >8000 and ≤10000 >10000 and ≤12500 >10000 and ≤12500 >10000 and ≤12500 *), B=Basic, S=Supplementary and R=Reinforced Verdict - - - - TABLE: Creepage distances, basic, supplementary and reinforced insulation N Creepage distance Working vo
LVD TEST REPORT Report Number : KSQ-LVD081010 Clause Requirement - Test Result - Remark Verdict >400 and ≤500 >500 and ≤800 >800 and ≤1000 >1000 and ≤1250 >1250 and ≤1600 >1600 and ≤2000 >2000 and ≤2500 >2500 and ≤3200 >3200 and ≤4000 >4000 and ≤5000 >5000 and ≤6300 >6300 and ≤8000 >8000 and ≤10000 >10000 and ≤12500 30.
LVD TEST REPORT Report Number : KSQ-LVD081010 Test Equipments List Description Manufacturer Model Number Serial Number Cal.
LVD TEST REPORT Report Number : KSQ-LVD081010 External Photographs EUT: Front/Rear View Page 61 / 63
LVD TEST REPORT Report Number : KSQ-LVD081010 Appendix K - Schematics Diagram See attached document(s).
LVD TEST REPORT Report Number : KSQ-LVD081010 Appendix L - User's Manual See attached document(s).