Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 32 / 63
26.3
Terminals for type X attachment and for connection
to fixed wiring so constructed that the conductor is
clamped between metal surfaces with sufficient
contact pressure and without damaging the
cond u ctor
Y attachm e nts N
Terminals for type X attachment and those for connection to fixed wiring so fixed
that when tightening or loosening the clamping means:
N
- the terminal does not loosen
N
- internal wiring is not subjected to stress N
- clearances and creepage distances are not
reduced below the values in 29
N
Com pliance checked by inspection and by the test
of subclause 8.6 of IEC 60999-1, the torque applied
being equal to two-thirds of the torque specified.
Nom inal diameter of thread (mm); screw category;
torque (Nm )............................................................:
N
26.4
Terminals for type X attac hment, exce p t those with
a specially prepared cord, and those for connection
to fixed wiring, no special preparation of conductors
required, and so constructed or placed that
conductors prevented from slipping out
Y attachm e nts N
26.5
Terminals for type X attac hment so locate d or
shielded that if a wire of a stranded conductor
escapes, no risk of accidental connection to other
parts that result in a hazard
See above N
Stranded conductor test, 8 mm insulation removed
N
No contact between live parts and accessible metal
parts and, for class II constructions, between live
parts and metal parts separated from accessible
metal parts by supplementary insulation only
N
26.6
Terminals for type X attachment and for connection
to fixed wiring suitable for connection of conductors
with req uire d cross-se ctio na l area accord in g to
table 13; rated current (A); nom inal cross-sectional
area (mm²)..............................................................:
N
Terminals only suitable for a specially prepared
cord
N
26.7
Terminals for type X attach m e n t acce ssible after
removal of a cover or p art of the enclosure
N
26.8
Terminals for the connection to fixed wiring,
includ ing the ea rt hing terminal, located close to
each other
P