Technical data

LVD TEST REPORT
Report Numbe r : KSQ-LVD 081010
Clause Requirement - Te st Result - Remark Verdict
Page 43 / 63
Needle-flame test carried out in accordance with
IEC 60695-2-2, with the following modifications:
N
5
Severities
N
The duration of application of the test flame is 30 s ±
1s
N
8
Test procedure
N
8.2
The specimen so arranged that the flame can be
applied to a vertical or horizontal edge as shown in
the examples of figure 1
N
8.4
The first paragraph does not apply
N
If possible, the flame is applied at least 10 mm from
a corner
N
8.5
The test is carried out on one specimen
N
If the spec im e n do e s no t withs tand the test, the test
may be repeated on two further specimens, both
withstanding the test
N
10 Evaluation of test results N
The duration of burning not exceeding 30 s N
However, for printed circuit boards, the duration of
burning not exceeding 15 s
N
F ANNEX F (NORMATIVE) CAPACITORS
Capacitors likely to be permanen tly subjected to the
supply voltage, and used for radio interference
suppression or voltage dividing, comply with the
following clauses of IEC 60384-14, with the
follow in g mod ificatio n s :
N
1.5 Terminology N
1.5.3
Class X capacitors tested according to subclass X2
N
1.5.4
This subclause is applicable
N
1.6
Marking
N
Items a) and b) are applicable N
3.4 Approval testing N
3.4.3.2 Table II is applicable as described N
4.1
Visual examination and check of dimen sions
N
This subclause is applicable
N