DaeWoo Dehumidifier Use and Care Manual Model #: DHC-250, DHC-400, DHC-600 Please read this manual thoroughly before operating the unit. Keep away from children. If any other issues arise, please consult your dealer or Daewoo Electronics for help. Keep this manual away from harmful substances and do not dispose of it.
Limited Warranty DAEWOO ELECTRONICS AMERICA, INC. warrants the enclosed dehumidifier against defective material and workmanship. Daewoo agrees to remedy any defective material or workmanship at the Company’s expense under the condition that normal installation, use and service disclosed such defect. The customer must deliver the unit to either the store or dealer where it was purchased or a Daewoo authorized Service Center.
Contents Usage: Functions 3 Safety 4 Placement and Usage 4 Installation and Operation: Operating Conditions 5 Turning the Unit “on” and “off” 5 Water Tank 6 Continuous Drainage 6 Care and Maintenance: Parts 7-8 Control Panel 7 Care and Troubleshooting 9-10 Technical Specifications 11 2
ATTENTION Read this instruction manual carefully before using your dehumidifier. Functions The dehumidifier helps prevent mold on clothing, etc. Open closet doors and dresser drawers before starting the dehumidifier. The dehumidifier prevents condensation on ceiling, walls, and glazing. To obtain best results, refrain from opening and closing the windows. Dehumidifying is effective on moisture sensitive items like musical instruments, cameras, computers, etc.
Safety Do not connect the unit to any damaged AC electrical socket. Ensure removable covers and containers are correctly fitted before switching the unit “on”. Always switch the unit “off” at the outlet before unplugging. Never insert finger or foreign objects into grills or openings. Take special care to warn children of these dangers. Always unplug the unit before cleaning. Do not cover the unit. Do not spray insecticides or any flammable sprays on the machine.
Operation Installation Install the mobile dehumidifier in a flat and spacious location. Do not cover up air vents. Do not install underneath desks or inside cupboards because this restricts air flow. Maintain a clearance of approximately 8 in. in front of and behind the unit to maintain optimal air flow. Operation Operating Conditions: This unit is designed to operate between 55°F and 95°F. Allow approximately 3 minutes after switching unit “on” for the correct operation to resume.
Water Tank: Water will drain into the tank. When the tank is full and the unit stops operating, the “Water Full” indicator will flash. Wait until the machine stops before removing the water tank. Removing it before the unit completely stops may cause some water to drip. To empty the water tank, consult the diagram below. Return the water tank to the same position as when you removed it. The machine will restart when the water tank is replaced in the correct position. Continuous Drainage: 1.
Parts CONTROL PANEL A. ON/OFF Button: When the unit is connected to power, the POWER indicator will flash slowly. Press the On/Off Button and the unit will go directly into dehumidifying operation with the original factory humidity setting (60% RH). Press the On/Off button to stop operation. B. CONT button: When the unit is in operation, pressing the “Cont.” Button will start “Continuous Dehumidifying” mode.
Parts C. FAN Button: By pressing the “Fan” button, the fan speed will change. Push the button once for “High Fan” mode. Press again for “Low Fan”. Pressing the button again will return the unit to “High Fan” mode. D. POWER Indicator: Once connected to a power source, this will flash slowly indicating the unit is “on”. If this indicator doesn’t blink, it indicates that the unit is “off”. E. CONT Indicator: This lights up when the unit is in “Continuous Dehumidifying” mode. F.
Care Be sure to unplug the unit before cleaning. The use of petrol, thinners, or other chemical agents while cleaning may damage the unit. Do not clean under running water. Doing so may damage the internal electrical components causing the unit to become unsafe to operate. Air Filter: Cleaning the air filter at least every two weeks will prevent impaired performance of the unit. To Clean: - Remove the water tank as shown in Figure A. Remove the air filter as shown in Figure B.
Troubleshooting Unit fails to operate: Possible Issue Corrective Action Power may be off Switch power “on” Power cord may be Restore power cord unplugged Water tank may not be Reposition water tank fitted correctly Water tank may be full Empty water tank Defrosting After defrosting, unit will continue to dehumidifying again.
Technical Specifications Model Dehumidifying Capacity 7.4 gallons/d Power Current Supply 115V - 6.3A 60Hz Working Environment 730W DHC400 DHC250 6.3 gallons /d 115V - 4.5A 60Hz 115V - 3.7A 60Hz 510W Model Water tank volume 2.1 gallons DHC600 DHC600 3.2 gallons /d DHC400 2.1 gallons DHC250 2.1 gallons Net weight 55.11 pounds 350W Dimensions H- 25 inches W 13.8 inches D 16.7 inches 52.9 pounds H- 25 inches W 13.8 inches D 16.7 inches 52.9 pounds H- 25 inches W 13.8 inches D 16.