R OOM AIR C ONDITIONE R US E & C AR E MANUAL P OR TAB L E TY P E R OOM AIR C ONDITIONE R MODE L #: UL and C UL listed C R LIS TE D DOC-091R DOC-091R H US P lease read carefully and thoroughly this manual before operating the unit. If you still have any difficulties or problems, consult your dealer for help or E LE C TR ONIC S . P lease keep this manual well.
CONTENTS 1.SAFETY RULES............................................................................. 1 2.NAMES OF PARTS.......................................................................... 2 3.ACCESSORIES................................................................................ 2 4.OPERATION PANEL OF THE AIR CONDITIONER........................ 3 5.OPERATING INSTRUCTION FOR THE AIR CONDITIONER ........ 4 6.INSTALLATION...............................................................................
SAFETY RULES 1. DO NOT CONNECT UNIT TO ANY AC SOCKET IN DISREPAIR OR WITH CONNECTIONS. 2. DO NOT USE IN THE FOLLOWING LOCATIONS: - NEXT TO SOURCE OF FIRE. - AN AREA WHERE OIL IS LIKELY TO SPLASH. - AN AREA EXPOSED TO DIRECT SUNLIGHT. - AN AREA WHERE WATER IS LIKELY TO SPLASH. - NEAR A BATH, A SHOWER OR A SWIMMING POOL - IN THE GREEN HOUSE 3. NEVER INSERT YOUR FINGERS OR ANY FOREIGN OBJECTS INTO THE AIR OUTLET. TAKE SPECIAL CARE TO WARN CHILDREN OF THESE DANGERS. 4.
NAMES OF PARTS OPRATION PANEL REAR COVER AIR INLET FRONT COVER AIR OUTLET AIR OUTLET OUTDOOR WATER PUMP DRAIN HOSE AIR INLET OUTDOOR REMOTE CONTROLLER CASTER INDOOR CONTINUOUS DRAIN HOSE POWER CORD SIDE VIEW FRONT VIEW AIR INLET OUTDOOR REAR VIEW Fig.
OPERATION PANEL OF THE AIR CONDITIONER(COOLING AND HEATING) DIGITAL DISPLAY FAN SPEED INDICATOR COOL/DRY/FAN/HEAT INDICATIOR Green lamp will light when the mode is selected WATER FULL INDICATOR Red lamp will blink when the tank is full TEMP SETTING BUTTON Press your desired room temperature setting by pressing the button (up) or button (down) POWER INDICATOR INFRARED SIGNAL RECEIVER POWER BUTTON Turn on/off the unit MODES BUTTON Select the operation mode from COOL.DRY.FAN.
OPERATING INSTRUCTING FOR THE AIR CONDITIONER Before Starting This Unit 1) Select a suitable location, make sure you have easy access to an electrical outlet. 2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.5 & Fig.5a Fig.5a Fig.5 NOTE: Step 2 is required only while using the cooling mode 3) Plug the unit into a 115V~60Hz grounded electrical outlet. 4) Make sure the water pump drain hose is correctly installed.
O O O O 2 COOLING OPERATION (Operating temperature range: 17 C-32 C/63 F-90 F) - Press the "MODE" button several times until the "COOL" indicator light comes on. - Press the "TEMP SETTING" buttons " " or " " to select your desired room temperature. (17OC-30OC/63OF-86OF) - Press the "FAN SPEED" button to choose the fan speed. O O O O 3 DEHUMIDIFYING OPERATION (Operating temperature range: 13 C-32 C/55 F-90 F) - Press the "MODE" button several times until the "DRY" indicator light comes on.
INSTALLATION 1 IMPORTANT: Install the mobile ir conditioner in a flat and spacious location where the air outlets will not be covered up. A minimum clearance of 30cm from a wall or other obstacles should be kept. The appliance shall not be used in the laundry. The plug shall accessible after appliance is positioned. Wiring shall be done according to National rules. 30c m 30 cm Fig.7 2 DUCT MOUNT INSTRUCTIONS: Exhaust Air Oulet Duck Fig.8 A) TEMPORARY1.
Window Kit Installation Your window kit has been designed to fit most standard Vertical and horizontal window applications, However, it may be necessary for you to improvise/modify some aspects of the installation procedures for certain types of window. Please refer to Fig. 11 & Fig. 11a for minimum and maximum window openings.
TROUBLE SHOOTING TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES 1. UNIT DOES NOT - Water full indicator blinks, water tank Dump the water in the water tank. START WHEN is full. PRESSING 1/0 BUTTON - Room temperature is higher than Reset the temperature. the set temperature.(Heating mode) - Room temperature is lower than Reset the temperature. the set temperature.(Cooling mode) 2. NOT COOL ENOUGH - The windows or doors in the room are not closed.
L imited Warranty DAE WOO E LE C T R ONIC S AME R IC A, INC . warrants the following P ortable room airconditioner to be free from defective material and workmans hip and agrees to remedy any s uch defect or to furnis h a new part (at the C ompanyĆs option) in exchange for any part of any unit of its manufacture which under normal ins tallation, us e and s ervice dis clos ed s uch defect, provided the unit is delivered by the owner to s tore or dealer where purchas ed or Daewoo authorized s ervice center.