DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지1 SAFETY INSTRUCTIONS PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE INSTALLING AND OPERATING THE UNIT: This air conditioner meets strict safety and operating standards. The installer of this unit must install or service this unit so it operates safely and efficiently. Precautions When Wiring: • Do not plug in the unit until all connections (tubing, drain hose, mounting, etc.) have been made and double-checked.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지2 CONTENTS It is recommended that you read the Installation and Operating instructions fully before installing and/or operating this unit. Safety Instructions ...........................................................................................................................................................1 Contents....................................................................................................................................................
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지3 BASIC ACCESSORIES This Installation section explains how and where to connect this new air conditioner. Please read make sure all accessories are included as shown below and read manual thoroughly. This Installation section is provided to assist the person knowledgeable in air conditioner installation and should not be installed by anybody who is not thoroughly familiar with this type of installation. Please contact a professional installer if necessary.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지4 OPTIONAL ACCESSORIES ACCESSORIES NOT SUPPLIED WITH THE UNIT: 5 3 2 1 6 4 7 8 (DSB-122LH Only) No. Description Part No. Qty Material Size 1 Drain Hose Extension 3103200200 1 PVC ID19.6 X 2m PVC Pipe 2 Tape 2TQ1008000 1 PVC 80W X 0.1T X 3.5m 3 Copper Tubing Extension 3100002600 1 4 Insulator Plate 3103301000 1 5 Putty 2221040001 1 80g 6 Connection Cord 3102797200 1 (1.5mm2 X 6m X 3P) 7 Signal line Cord 3102796360 1 (1.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지5 LOCATION OF CONTROLS INDOOR UNIT Indoor Cover Air In Deodorizing Filter Removes bad smells from the air. Remote Controller Storage Electrostatic Filter Connection Cover Removes dust particles from the air. Remove cover to access the AC connection from this unit to the outdoor unit. Air Cleaning Filters Removes dust and prohibits germs.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지6 INDOOR UNIT Indoor Unit Display Switch Panel ■Remote Control Signal Receiver This place is the part to receive the signal if it receive the signal, you can hear the signal “beep”. ON AIR CLEAN QUICK EMERGENCY EMERGENCY TIMER ON (Red) Lights-on during the operation Timer (Green) Lights-on during the time of reservation mode. Air clean (Green) Lights-on during the operation Quick (Green) Lights-on during the time of Quick Mode.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지7 DSB-122L REMOTE CONTROLLER Display Displays information pertaining to unit. AUTO ON/OFF Button Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower the desired temperature. FAN SPEED Button Press to select the fan speed (High " ", Middle " ", Low " ", Natural). MODE FAN SPEED FAN DIR. FAN DIR. Button Press to select up/down direction for fan.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지8 DSB-122LH REMOTE CONTROLLER Display Displays information pertaining to unit. AUTO ON/OFF Button Press to turn the unit on or off. FAN SPEED Button Press to select the fan speed (High " ", Middle " ", Low " ", Natural) MODE Button Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier /Heat) TEMPERATURE Buttons Press to raise or lower the desired temperature. MODE FAN SPEED FAN DIR. FAN DIR. Button Press to select up/down direction for fan.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지9 OPERATION CONNECTING THE AC CORD The outdoor unit is connected to the indoor unit through the AC connecting wire or connection cord. To connect the indoor unit to AC, follow the procedures below: 1. Insert the attached AC plug AC Outlet into a pronged and Plug 220V AC outlet. NOTES: • Never connect the AC line cord plug to other than the specified voltage (220V). • Use the attached power cord only. • The new air conditioner system should be on it’s own 220V circuit.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지10 HOW TO INSTALL BATTERIES To install the batteries, follow the procedures below: TIMER ON/OFF ENTER/ CANCEL TURBO/MILD + – 2. Insert two “AAA” size Alkaline batteries following the polarity diagram below. 1. Slide down the cover to access most of the remote buttons. Slide down further to access the battery compartment. – + BATTERY PRECAUTIONS The precautions below should be followed when using batteries in this device: 1.
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지11 TO SET AUTO MODE This unit will automatically operate the unit according to its surroundings while in the Auto mode. All you have to set is the desired temperature and it will control the fan, coolness and dehumidifier. Follow procedures below: 1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ON” will light in the remote display. 2. Make sure the AUTO indicator AUTO appears in the remote display.
DSB-122L/122LH(영어) 01.8.17 5:28 PM 페이지12 TO SET FAN ONLY MODE To operate only the fan so the unit will circulate the air, proceed as follows: 1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ON” will light in the remote display. 2. Press the MODE button until the Fan indicator appears in the display. No allowance setting temperature 3.
DSB-122L/122LH(영어) 01.8.17 5:28 PM 페이지13 TO SET HEAT MODE (DSB-122LH ONLY) To set the unit to heat the room to a desired temperature, follow the procedures below: 1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ON” will light in the remote display. 2. Press the MODE button until the Heat indicator appears in the display. In the heat mode, the fan direction ▼ or ▲ is further downward than that in the cool mode for the good circulation. 3.
DSB-122L/122LH(영어) 01.8.17 5:28 PM 페이지14 TO SET ON TIMER MODE This unit can be set to automatically turn on after a predetermined amount of hours (up to 24) in the order of 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 12, 16, 20, 24. 1. Press the ON/OFF button of timer on the remote control to set the on timer mode, “HOUR” and “ON” on the remote display will be displayed and “TIMER” will be flicked. When you increase to press “ON/OFF” you will get desired time.
DSB-122L/122LH(영어) 01.8.17 5:28 PM 페이지15 TO SET UNIT TO SLEEP MODE When you are going to sleep, select this feature and the unit will cool off the room to the desired temperature and then increase that temperature throughout the night. 1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ON” will light in the remote display. 2. Press the MODE button to select the desired mode. Then, set the desired temperature using the TEMP. ▲ or ▼ buttons.
DSB-122L/122LH(영어) 01.8.17 5:28 PM 페이지16 CHANGING/CLEANING THE AIR FILTERS To change or clean the two black air filters, follow the procedures below: 1. Open the indoor unit’s cover and remove both black air filters by bending them slightly backward and the lifting out. 2. Remove the two small filters (Deodorizing and Electrostatic) from the indoor unit. 3. Examine the filters and determine if they need to be cleaned or replaced. To clean filters, use a vacuum and clean off dust.
DSB-122L/122LH(영어) 01.8.17 5:28 PM 페이지17 CARE AND MAINTENANCE warning • Make sure the AC cord is unplugged and the unit is off before cleaning. • Do not use water on the unit to clean it. This is a shock hazard and the unit can be damaged. Clean the casing and front of the indoor unit with a vacuum brush or wipe with a clean damp cloth. • NEVER USE Solvents, harsh chemicals or hot water to clean the unit. • Some metal edges on the unit are sharp. Be careful when cleaning or handling.
DSB-122L/122LH(영어) 01.8.17 5:28 PM 페이지18 TROUBLESHOOTING GUIDE Before requesting service, please refer to the chart below for possible solutions: SYMPTOMS No power . POSSIBLE CAUSE POSSIBLE SOLUTIONS Power failure. Restore the power Line voltage too low. Contact electrician to install new outlet. Unit is unplugged or not completely plugged in. Insert plug all the way. Unit is off. Turn unit on. Batteries in remote are weak or dead. Replace remote’s batteries.
DSB-122L/122LH(영어) 01.8.17 5:28 PM 페이지19 SPECIFICATIONS MODEL Function DSB-122L DSB-122LH Cooling Cooling / Heating (Heat pump) Power Supply AC 220-240V, 50Hz Cooling Capacity (Heating Mode) 3,024 Kcal/h 3,150 Kcal/h (3,402 Kcal/h) Operating Current (Heating Mode) 5.7A 7.0 A (6.3 A) 1,250W 1,500 W (1,410 W) Power Consumption (Heating Mode) Indoor Unit Dimensions W 925 x H 285 x D 194 mm Outdoor Unit Dimensions W 666 x H 552 x D 264 mm Indoor 9.