Operation Manual
10
OPERATION
1. Insert the attached AC plug into a 2-pronged only
220V or 220V-240V AC outlet.
AC Outlet
and Plug
NOTES:
• Never connect the AC line cord plug to other than the
specified voltage (only 220V or 220-240V).
• Use the attached power cord only.
• If the outlet is a 3-pronged type or others, have an elec-
trician install a new outlet.
• The new air conditioner system should be on it’s own
220V circuit. Contact your local electrical installer for in-
stallation.
CONNECTING THE AC CORD
The outdoor unit is connected to the indoor unit through the AC connecting wire or connection cord. To connect the in-
door unit to AC, follow the procedures below:
Plug into only 220V or 220V-240VAC Outlet.
SETTING THE UNIT FOR REMOTE OPERATION
After the unit is fully connected and plugged in, it can be turned on. To turn the unit on and set it for remote operation,
follow the procedures below:
1. Open the indoor unit’s cover and make sure the
EMERGENCY/REMOTE switch is set to the REMOTE
position; this will allow the unit to operate with the re-
mote controller.
EMERGENCY/REMOTE Switch
REMOTE
EMERGENCY
2. Press the ON/OFF button on the remote controller to
turn on the unit. The On LED will light on the indoor
unit and “ON” will light in the remote display.
To select the various modes and settings, read the
following pages.
THREE MINUTE COMPRESSOR DELAY
• After turning the indoor unit on and setting it for air con-
ditioner operation, the compressor (outdoor unit) will
not come on for three minutes. This is a feature that
will protect the compressor from damage due to quick
start and stops.
INFORMATION:
1. The plug shall be connected to a ground socket outlet, and the interconnection cord shall be connected by an authorized
electrician or specialist.
2. Information for interconnection cable:
3. Contact service man for the installation shall be in accordance with national wiring regulation
Items Specifications
Under 12K class AC 250V, 16A, H05VV-Fx1.0m
2
Above 12K class AC 250V, 16A, H05VV-Fx1.5m
2
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지10