Manual de servicio Acondicionador de Aire Tipo Split Modelo : DSB-070L/DSB-071L DSB-091L/DSB-092L DSB-121L/DSB-122L DSB-123L/DSA-123L DSA-181L DSB-181L DSB-182L/L-R DSB-183L-R DSA-182L/DSA-183L-R DSA-183L DSB-240L-R DSA-240L-R DSA-240L
Contents CONTENTS 1. Specifications..........................................................................................................2 2. Outline and Dimensions.......................................................................................13 3. Operation ..............................................................................................................23 4. Wiring Diagram.....................................................................................................47 5.
1. SPECIFICATIONS ◆DSB-070L/071L MODEL DSB-070L/071L ITEM Function Cooling Class T1 Power AC 220~ 240V/ 50Hz Capacity W 2,051 Btu/h 7,000 l/h 0.89 Running Current A 2.7 Power Input W 650 Starting Current A 18 Dehumidification Electrical Data Compressor Type Rotary Model RBB070A011 Capacitor Fan Motor 25µF / 400VAC Indoor Unit Outdoor Unit Type Cross flow fan Propeller fan Capacitor 1.0µF 400VAC 1.
◆DSB-091L/092L MODEL DSB-091L/092L ITEM Function Cooling Class T1 Power AC 220~240V/ 50Hz Capacity W 2,637 Btu/h 9,000 l/h 1.15 Running Current A 4.0 Power Input W 900 Starting Current A 21 Dehumidification Electrical Data Compressor Type Rotary Model RBB095A011 Capacitor Fan Motor 25µF / 370VAC Indoor Unit Outdoor Unit Type Cross flow fan Propeller fan Capacitor 1.0µF 400VAC 1.
◆DSB-121L/122L MODEL DSB-121L/122L ITEM Function Cooling Class T1 Power AC 220~240V/ 50Hz Capacity W 3,517 Btu/h 12,000 l/h 1.53 Running Current A 5.7 Power Input W 1,250 Starting Current A 34 Dehumidification Electrical Data Compressor Type Rotary Model RCB 120A001 Capacitor 25µF/ 370VAC Division Fan Motor Indoor Unit Outdoor Unit Type Cross flow fan Propeller fan Capacitor 1.0µF 400VAC 3.
◆DSB-123L/DSA-123L MODEL DSB-123L ITEM DSA-123L Function Cooling Class T1 Power AC 220~240V/ 50Hz Capacity Dehumidification Electrical Data W 3,517 Btu/h 12,000 l/h 1.35 Running Current A 5.7 Power Input W 1,300 1,200 Starting Current A 34 29 Type Compressor Rotary Model RCB 120A001 QK173KAJ Capacitor 25µF/ 370VAC 25µF/ 400VAC Division Fan Motor Indoor Unit Outdoor Unit Outdoor Unit Type Cross flow fan Propeller fan Propeller fan Capacitor 1.5µF 400VAC 3.
◆DSA-181L/DSB-181L MODEL DSA-181L ITEM DSB-181L Function Cooling Class T1 Power Supply AC 220V, 60Hz AC 220~240V, 50Hz W 5,129 5,100 Btu/h 18,000 17,500 2.3l/h 2.3l/h 8.0A 9.8A 1,750W 1,950W 42A 46A Type Rotary RECIPRO Model RCA180U001 CRDQ-0200-PFJ Capacitor 35µF/370 VAC 30µF/400 VAC Capacity Dehumidification Running Current Electrical Data Power Input Starting Current Compressor Type Indoor Cross Flow Fan Outdoor Capacitor Propeller Fan Indoor 1.
◆DSB-182L/182L-R/183L-R MODEL DSB-182L ITEM DSB-182L-R Function DSB-183L-R Cooling Class T1 Power AC 220~240V/ 50Hz Capacity W 5,129 5,275 5,275 Btu/h 17,500 18,000 18,000 l/h 2.3 2.3 2.3 Running Current A 9.6 9.2 9.
◆DSA-182L/183L-R MODEL DSA-182L ITEM DSA-183L-R Remark JIS C9812 Function SAA 385, 386 Cooling Class T1 Power AC 220V/ 60Hz Capacity W 5,129 5,275 4,500 Btu/h 17,500 18,000 15,354 Dehumidification l/h 2.3 Electrical Data Running Current A 8.3 9.4 10.4 Power Input W 1,785 2,000 2,200 Starting Current A 44 52 52 Compressor Type Rotary Recipro Model ECB185211A AWG5519EXN 30µF / 370VAC 25µF / 400VAC Capacitor Fan Motor Refrigerant (R-22) 2.
◆DSA-183L MODEL DSA-183L ITEM Remark JIS C9812 SAA 385, 386 Function Cooling Class T1 Power AC 220V / 60Hz W 5,270 4,450 Btu/h 18,000 15,200 Capacity Dehumidification Electrical Data Compressor l/h 2.5 Running Current A 10.4 11.
◆DSB-240L-R MODEL DSB-240L-R ITEM Function Cooling Class T1 Power AC 220~240V/ 50Hz W 6,594 Btu/h 22,500 l/h 3.2 Running Current A 13.
◆DSA-240L-R MODEL DSA-240L-R ITEM Remark AHAM Function Cooling Class T1 Power AC 220V / 60Hz W 7,034 5,129 Btu/h 24,000 17,500 Capacity Dehumidification Electrical Data l/h 2.86 Running Current A 11.
◆DSA-240L MODEL DSA-240L ITEM Remark JIS C9812 SAA 385, 386 Function Cooling Class T1 Power AC 220V / 60Hz W 7,030 5,860 Btu/h 24,000 20,000 Capacity Dehumidification Electrical Data Compressor Fan Motor l/h Running Current A 10.8 13.
2.
◆DSB-071L/DSB-092L 750 Connecting Pipe Plate Mounting REMOCON Grille Insert 245 Frame Grille Body 179 Plate Mounting 14
◆DSB-121L/122L Filter - L Connecting Pipe Plate Mounting Plate Mounting Body Frame Grille Grille Insert 194 REMOCON 15 406 925 Filter - R 285
◆DSB-123L/DSA-123L 815 Insert Grille Frame Grille Body 16 Connecting Pipe Plate Mounting 195 285
◆ DSA-181L/DSB-181L Filter-L Connecting Pipe ¿‹ Æ˘˜ ˙` 453 453 1035 1035 Filter-R Plate ”fi Mounting `⁄˘˙ REMOCON ˜ `⁄„«…–‚fi‚ Grille Insert ‰˙‡»– ‚Ø– ‚– 322 ‰˙‡»– ‚ ˆ… Body 205 17
◆DSB-182L/182L-R, DSA-182L Filter-L Connecting Pipe 453 1035 Filter-R Plate Mounting REMOCON Grille Insert 1035 Body 322 18
◆DSA-183L-R/DSA-240L-R, DSB-183L-R/240L-R, DSA-183L/240L Connecting Pipe Filter-L 430 710 1080 Grille Insert REMOCON Body 200 Frame Grille Plate Mounting Filter-R 298 19
2 OUTDOOR UNIT ◆DSB-070L/071L/DSB-091L/092L/DSB-121L/122L/123L Inlet Outlet Foot Cushion Cabinet Front Fot Ssrvice Valve Ssrvice Valve 549 Cabinet Side Panel Top Guide Support 20 Inlet Outlet 654 256
◆DSB-181L/182L/182L-R/183L-R, DSA-181L/182L/183L/183L-R Inlet Outlet Foot Cushion Inlet Outlet Cabinet Front 800 320 Foot 380 Handle Service Valve 615 Cabinet Side Guide Support Panel Top 21
◆DSB-240L-R/DSA-240L-R/DSA-240L Inlet 873 Cabinet front foot 323 380 Service Cover Cabinet Side Service valve 699 22
3. OPERATION 1 NAME AND FUNCTION OF PARTS Indoor Unit ◆DSB-070L/DSB-091L Electrostatic Filter(Option) Removes dust and particles from the air Air Inlet Deodorizing Filter(Option) Removes bad smells from the air. Lamp Antibacterial Filter Removes dust and prohibits germs.
◆DSB-071L/DSB-092L Electrostatic Filter(Option) Removes dust and particles from the air Air Inlet Deodorizing Filter(Option) Removes bad smells from the air. Lamp Antibacterial Filter Removes dust and prohibits germs.
◆DSB-121L/122L Electrostatic Filter Air Inlet Removes bad smells from the air. Removes dust and particles from the air Antibacterial Filter Air Outlet Deodorizing Filter Fan Direction (Up, Down) Removes dust and prohibits germs.
◆DSB-123L/DSA-123L Air Inlet Deodorizing Filter Removes bad smells from the air. Antibacterial Filter Removes dust and prohibits germs.
◆ DSB-181L/182L/182L-R, DSA-181L/182L Deodorizing Filter Removes bad smells from the air. Test/Emergency/ Remote Switch Electrostatic Filter Removes dust particles from the air. Air In Slide to select the desired position. Indoor Cover Air Cleaning Filters Removes dust and prohibits germs. Remote Sensor Indicators Cold Air Indicate the AC setting. Fan Direction (Up/Down) . MP TE /OFF ON DE MO P EE SL R.
◆ DSA-183L-R/DSA-240L-R, DSB-183L-R/240L-R, DSA-183L/240L Deodorizing Filter Removes bad smells from the air. Electrostatic Filter Removes dust particles from the air. AIR IN Indoor Cover Air Cleaning Filters Removes dust and prohibits germs. AIR OUT Remote Sensor Fan Direction (Up/Down) Emergency/Remote Switch Indicators Indicate the AC setting. R.
◆DSB-070L/DSB-091L Indoor Unit Display Switch Panel ■Remote Control Signal Receiver This place is the part to receive the signal if it receives the signal, you can hear the signal “beep. “beep. beep.” EMR. REMOCON ■ There is a switch panel at inside of Front Panel. At the time of operating, open the Front Panel. ON (Red) Lights when the operation is going on. Air clean (Green) Timer (Yellow) Lights during the time reservation mode.
◆DSB-071L/DSB-092L Indoor Unit Display Switch Panel ■Remote Control Signal Receiver This place is the part to receive the signal if it receives the signal, you can hear the signal “beep. “beep. beep.” EMR. REMOCON ■ There is a switch panel at inside of Front Panel. At the time of operating, open the Front Panel. ON (Red) Lights when the operation is going on. Air clean (Green) Timer (Yellow) Lights during the time reservation mode.
◆DSB-121L/122L ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
◆DSB-123L/DSA-123L Indoor Unit Display Switch Panel ■Remote Control Signal Receiver This place is the part to receive the signal if it receives the signal, you can hear the signal “beep. beep”. EMERGENCY REMOCON REMOCON EMERGENCY Air clean (Green) ON (Red) Lights when the operation is going on. Timer (Yellow) ■There is a switch panel at inside of Front Panel. At the time of operating, open the Front Panel. Lights during the time reservation mode.
◆ DSB-181L/182L/182L-R, DSA-181L/182L Indoor Unit Display Switch Panel ■ Remote Control Signal Receiver This place is the part to receive the signal if it receives the signal, you can hear the signal “beep. beep”. EMERGENCY REMOTE Timer Quick Airclean ON ■ There is a switch panel at inside of Front Panel. At the time of operating, open the Front Panel. Timer (Yellow) Lights during the time reservation mode. ON (Red) Lights when the operation is going on.
◆DSA-183L-R/240L-R, DSB-183L-R/240L-R, DSA-183L/240L Indoor Unit Display Switch Panel ■ Remote Control Signal Receiver This place is the part to receive the signal if it receives the signal, you can hear the signal “beep. “beep, beep.” REMOCON EMERGENCY EMERGENCY REMOCON ON (Red) Lights-on during the operation Timer (Yellow) Lights-on during the time of reservation mode. Air clean (Green) Lights-on during the operation Quick (Red) Lights-on during the time of Quick Mode.
Outdoor Unit ◆DSB-070L/071L/DSB-091L/092L/DSB-121L/122L/123L/DSA-123L AIR IN Connection Cover Remove cover to access the AC connection to the indoor unit. Service Valves AIR OUT The indoor and outdoor units are connected by copper tubes which are connected here.
◆ DSB-181L/182L/182L-R/183L-R, DSA-181L/182L/183L/183L-R AC Cover Remove cover to access the AC connection from this unit to the indoor unit. AIR IN Connection Wire Drain Hose COPPER TUBING AIR OUT Service Valves The indoor and outdoor units are connected by copper tubes which are connected here. Grounding Screw Ground the unit here.
◆DSB-240L-R / DSA-240L-R / DSA-240L Connection wire Air Inlet Drain Hose Air Outlet Connection Pipe 37
2 REMOTE CONTROLLER Name of Each Button ◆ DSB-070L/DSB-071L/DSB-091L/DSB-092L/DSB-121L/DSB-122L/DSB-123L/DSA-123L DSB-183L-R/DSA-183L-R/DSB-240L-R/DSA-240L-R Display Displays information pertaining to unit. AUTO FAN SPEED Button Press to select the fan speed (High " ", Middle " ", Low " ", Natural). MODE Button Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier) ON/OFF Button Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower the desired temperature.
◆DSB-182L/182L-R, DSA-182L/DSA-181L Display Displays information pertaining to unit. AUTO FAN SPEED Button Press to select the fan speed (High " ", Middle " ", Low " ", Natural). MODE Button Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier) ON/OFF Button Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower the desired temperature. MODE FAN SPEED SLEEP FAN DIR. FAN DIR. TIMER ON/OFF ENTER/ CANCEL SLEEP Button Press to set the unit for the sleep mode.
3 REMOTE CONTROLLER DISPLAY MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier) Lights to indicate the mode selected. AUTO FAN Indicators Lights to indicate the fan speed. FAN DIRECTION Indicators Lights to indicate the fan direction. NATURAL Indicator Lights to indicate the speeds simulating a loreeze. TIMER Indicators (Include sleep) Lights to indicate the timer function mode. TEMPERATURE & RESERVATION TIME lndicator Lights to indicate the temperature or time.
4 DESCRIPTION OF FUNCTIONS OFF-Timer If you set time in OFF-Timer Mode, the unit will stop at the set time. ON Unit ON Unit OFF OFF SET Time HOUR ON-Timer If you set time in ON-Timer Mode, the unit will run at the set time.
Fan Speed (Indoor Unit) (1) Motor speed (high speed, middle speed, low speed). (2) Remote controller setting fan speed. (Auto, L, M, H, Natural) (3) Relation of operating mode between fan speed.
Sleep Mode (1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature. (The unit will not operate after 4 hour) (2) For changing the temperature. DT +0.5°C +0.5°C +0.5°C 0 0.5 1.0 HOUR (COOLING CYCLE) (3) To cancel sleep mode, press the SLEEP button again or press the MODE button once.: the SLEEP indicator will disappear in the display.
3 min. Time Delay of Compressor In normal operation, there is a time delay of three minutes between turn off and turning back on including initial power up.
Dehumidification Mode 1 Desired temperature < Room temperature Outdoor Fan, Compressor : ON Indoor Fan : Low speed 2 Desired temperature ≥ Room temperature Compressor : 3 min/ON, 5 min/OFF Fan Speed : low speed 3 Room temperature ≤ 18°C Compressor : OFF Fan speed : Low speed Air Discharge Direction(only remocon operation) The air discharge direction procedure is below.
Self-Diagnostic Function The control will contain diagnostic test to verify the integrity of the system. (1)Error Code Display Pattern 1 ON LAMP: Blink LED BLINK PATTERN CASE NOTE Room Sensor open or Short • Continuously woorking to fix room temperature 32°C in cooling mode • I/D coil sensor open or short Do not woorking 0.5s 8s 1 times blink • O/D coil sensor open or short • Compressor or electrical parts of compressor error.
4.
◆DSA-183L-R, DSB-183L-R, DSA-183L DSA-240L-R, DSB-240L-R, DSA-240L ◆DSA-181L/182L DSB-181L/182L/182L-R 48
Outdoor Unit ◆DSA-121L/122L, DSB-070L/071L DSB-091L/092L/121L/122L ◆DSB-123L/DSA-123L ◆DSA-181L/182L, DSB-181L/182L/182L-R, DSA-183L-R, DSB-183L-R, DSA-183L ◆DSA-240L-R/240L, DSB-240L-R 49
1 MAIN ELECTRIC PARTS ◆DSB-070L/071L PART NAME Indoor Unit Outdoor Unit Fan Motor Fan Motor Capacitor Fuse Stepping Motor Terminal Block Compressor Fan Motor Dual Capacitor Terminal Block PART CODE SPEC. 3108008700 3106900300 5FVLB3152L 3108003910 3108914100 3RC0020GE1 3108004000 3109501201 3108914100 YDK-8-4B 1.0µF 400VAC 250V 3.15A 24BYJ48-S1 JXO-CH-3P RBB070A011 YDK-30-6B 1.
◆DSB-123L/DSA-123L PART NAME Indoor Unit Fan Motor Fan Motor Capacitor Fuse Stepping Motor Terminal Block Compressor Outdoor Fan Motor Unit Dual Capacitor Terminal Block PART CODE SPEC. 3118003500 CMXW2G155K 5FVLB3152L 3108003910 3118900200 3100030CE0 3117148500 3108000800 3118007300 3109500700 3109502010 3108914100 RP13B 1.5uF, 400VAC 250V 3.15A 24BYJ48-S1 JXO-CH-2P RCB120A001 QK164KAJ YDK-40-4B KDK-35-6A 3.
◆DSB-183L-R PART NAME Indoor Unit Outdoor Unit Fan Motor Fan Motor Capacitor Fuse Stepping Motor Terminal Block Compressor Fan Motor Dual Capacitor Terminal Block PART CODE SPEC. 3108003800 3106902400 5FVLB3152L 3108007600 3108914100 3100068010 3108009100 3116901800 3108914100 220/50/60Hz 2.0uF 400VAC 250V 3.
5. REFRIGERANT CYCLE INDOOR UNIT Evaporator Cross flow fan Connecting pipe Service valve Service valve Capillary tube Accumulator Compressor Dryer Condenser Propeller fan OUTDOOR UNIT Refrigerant flow Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter. Contents Model Name Capillary Tube Charge Quantity Contents Model Name Capillary Tube Charge Quantity DSB-070L/071L DSB-091L/092L IDØ1.6xODØ3.2x900L IDØ1.6xODØ3.2x1200L IDØ1.6xODØ3.2x600L IDØ1.
6. CONTROL BLOCK DIAGRAM ◆DSB-071L, 092L, 123L/DSA-123L Unit on lamp Remote Air clean lamp Emergency Operating Mode Signal receiver Fan Speed Timer Selection Quick lamp Flap Position Operation Timer lamp Temp. Setting ON/OFF Room air temp. SLEEP Indoor coil temp.
◆DSB-121L/DSB-122L/DSA-181L/DSB-181L/DSB-182L/182L-R/183L-R/DSA-183L-R/ DSA-183L/DSB-240L-R/DSA-240L-R/DSA-240L Unit on lamp Remote Air clean lamp Emergency Operating Mode Signal receiver Fan Speed Timer Selection Quick lamp Flap Position Operation Timer lamp Temp. Setting ON/OFF Room air temp. SLEEP Indoor coil temp.
7. TROUBLE SHOOTING Is the unit display mormal? YES NO NO check the failure code according to the self-diagonostic (note 2) Is the unit display normal? YES Outdoor unit does not run?(note.
Note 1) 1 Neither indoor unit nor outdoor unit runs. Check the following points first. (There are following case in normal operation) a. Is the timer mode set the "timer ON". b. Is the timer mode set the "timer-OFF" and the time had passed? 2 Neither outdoor fan nor compressor runs while indoor fan runs. Check following points first. (There are following cases in normal operation) a. Is the temperature set point suitable? b.
Neither Indoor Unit nor Outdoor Unit Runs Confirm following statement. When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate. 1 Check the function select switch. Is it timer mode? 2 The function select switch locate the sleep mode and is the setting time over? 3 Is the setting mode DEHUMIDIFIER mode? 4 When the unit is DEHUMIDIFIER mode while in the auto mode, the outdoor unit and indoor unit does not run.
Outdoor Unit Runs but Indoor Fan Does Not Run Check rotation of indoor fan NO Check the Fan Motor bearing and fan Rating voltage Check the power P.C.B. Rotate indoor fan by hand YES Check input Voltage of Fan Motor connector at power P.C.
Outdoor Fan and Compressor Do Not Run Confirm following statement. When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate. 1 Is the setting temperature proper? 2 Is the unit during 3min. Time delay of compressor. 3 During frost prevention of lndoor unit. 4 During dehumidifier mode.
Only Compressor Does not Run - Check the following at cooling mode Rating voltage Check the voltge between L and Y of indoor unit terminal less than 90% Check the control P.C.B the circuit for relay driving. Rating voltage more than 90% Rating voltage Check the voltge between L and Y of outdoor unit terminal less than 90% Check the connecting wire between indoor and outdoor.
PCB DRIVING DESCRIPTION
1 PCB CIRCUIT DIAGRAM ◆DSB-070L, 071L, 091L, 092L, 123L/DSA-123L 63
◆DSB-121L, 122L, 181L, 182L, DSA-181L, 182L 64
◆DSB-183L, 240L, DSA-183L, 240L, DSA-181L 54
◆DSB-071L, DSB-092L PART LIST (INDOOR UNIT) PART NAME FUSE FUSE CLIP VARISTOR WAFER WAFER C-CERA C-CERA C-MULTI C-ELEC C-ELEC C-ELEC C-ELEC C-ELEC C-ARRAY C-ARRAY C-ARRAY RESISTOR SPEC 250V 50T 3.15A AFC-520 15G561K YW396-05AVD YW396-03AVD 104Z,50VDC 103Z,50VDC 104Z,CR0561B-Z5U 470uF 35V SD 10uF 450V SD 100uF 16V SD 10uF 16V SS 4.7uF 50V SS F3 104Z F4 104Z F5 104Z 1/4W-12.
◆DSB-123L PART LIST (INDOOR UNIT) PART NAME FUSE FUSE CLIP VARISTOR WAFER WAFER C-CERA C-CERA C-MULTI C-ELEC C-ELEC C-ELEC C-ELEC C-ELEC C-ARRAY C-ARRAY C-ARRAY RESISTOR SPEC 250V 50T 3.15A AFC-520 15G561K YW396-05AVD YW396-03AVD 104Z,50VDC 103Z,50VDC 104Z,CR0561B-Z5U 470uF 35V SD 10uF 450V SD 100uF 16V SD 10uF 16V SS 4.7uF 50V SS F3 104Z F4 104Z F5 104Z 1/4W-12.
◆183L-R/DSA-183L-R/DSB-240L-R/DSA-240L-R PART LIST(INDOOR UNIT) No PART CODE PART NAME SPEC Q'TY UNIT BZ1 3105698200 BUZZER DP-2520BA 1 EA CA1 CN5XD104M- C-ARRAY F5 104Z 1 EA CA2 CN4XD104M- C-ARRAY F4 104Z 1 EA CA3 CN3XD104M- C-ARRAY F3 104Z 1 EA CC 3108803500 PIN GP881206-2(250) 1 EA CC1 CCXE1E104M C-CERA 104Z 25VDC 1 EA CC10 CCXE1E104M C-CERA 104Z 25VDC 1 EA CC11 CCXE1E104M C-CERA 104Z 25VDC 1 EA CC13 CDXE1H104M C-MULTI CR501B-Z5U,104Z,50V 1 EA CC
No PART CODE IC5 1KA7042P-- IC6 L1 PART NAME SPEC Q'TY UNIT IC RESET KIA7042P 5L 1 EA 1KD65004AP IC DRIVER KID65004AP 1 EA 52C1374001 COIL 130UH 3A 1 EA OSC 4850103610 RESONATOR CST8.00MTW,8MHZ 1 EA PCB 3104398102 PCB CONTROL 160.5*140*1.6T.1(42) 1 EA PT1 1TLP560J-- IC PHOTO COUPLER TLP 560J 1 EA R-OPT 3104810000 RESISTOR OPTION NOTE OPTION TABLE 1 ST R1 RD-4K101J- R CARBON FILM 1/4 100 OHM J 1 EA R10 RN-4K1272F R METAL FILM 1/4 12.
◆CONTROL PCB ASS`Y (MODEL : 122L/LH,182L/L-R/LH/LH-R) No PART CODE PART NAME SPEC Q'TY UNIT CA1 CN4XD104M- C-ARRAY F4 104Z 1 EA REMARK CA2 CN3XD104M- C-ARRAY F3 104Z 1 EA CC1 CCXE1E104M C-CERA 104Z 25VDC 1 EA CC10 CCXE1H103M C-CERA 103Z 50VDC 1 EA CC13 CDXE1H104M C-MULTI CR501B-Z5U,104Z,50V 1 EA CC2 CCXE1E104M C-CERA 104Z 25VDC 1 EA CC3 CCXE1H103M C-CERA 103Z 50VDC 1 EA CC4 CCXE1H103M C-CERA 103Z 50VDC 1 EA CC5 CCXE1H103M C-CERA 103Z 50VDC 1 EA CC6
No PART CODE PART NAME SPEC Q'TY UNIT REMARK R2 RD-4K103J- R CARBON FILM 1/4 10K OHM J 1 EA R20 RN-4K1272F R METAL FILM 1/4 12.7K OHM F 1 EA R21 RD-4K331J- R CARBON FILM 1/4 330 OHM J 1 EA R22 RN-4K1272F R METAL FILM 1/4 12.
◆POWER PCB ASS`Y (MODEL : 122L/LH,182L/L-R/LH/LH-R) No PART CODE PART NAME BZ1 C1 C2 CC CC1 CC2 CC3 CC4 CE1 CE2 CE3 CL CLIP CN1 CN2 CN3 CN4 CN5 CN6 CN7 CN8 CN9 D1 D2 D3 D4 D5 D6 FUSE HS1 IC1 IC2 L1 PCB PT1 R1 R2 R3 R4 R5 R6 R7 RL1 RL1 RL2 RL3 RL4 SCRW T1 TR1 VAR WSHR 3105698200 CLV-B3104M CLV-B3104M 3108803500 CCXE1E104M CCXE1E104M CCXE1E104M CCXE1H103M CEXE1V108C CEXE1E477C CEXE1C107C 3108803500 3107000600 3108803900 3108803800 3108802900 3108802500 3108802800 3108802100 3108800320 3108803400 310880360
◆LED PCB ASS`Y (MODEL : 070L/LH, 071L/LH, 091L/LH,092L/LH) No PART CODE PART NAME CC1 CN1 HOLD L1 L2 L3 L4 PCB RCV SW1 CDXE1H104M 3108804800 3103002700 DDLS05031D DDLG05031D DDLS05031D DDLY05031D 3104398201 1TSP1838YA 5S40202000 C-MULTI WAFER HOLDER LED LED LED LED LED PCB LED RECEIVER MODULE S/W PUSH SPEC CR501B-Z5U,104Z,50V SMAW250-08 ABS DLSO-5031D(RED) DLG-5031D(GRN) DLSO-5031D(RED) DLY-5031D(YLW) 110*31*1.6T.
Power Supply(1) AC 220V FUSE1 12V VAR D2 D1 275V 104K CC1 CE1 IC2 7812 CC2 5V CE2 + 3.15A D4 D3 G VI VO 35V 1000µF 104 + 104 25V 470µF IC3 7805 VI VO CC3 G CL1 CE3 + 104 16V 100µF POWER TRANS DESCRIPTION DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac Driving Photo Triac, Buzzer Driving Swing, Sweep Motor. AC voltage of secondary Power Transformer is rectified by Bridge Diode, and it is filtering by Main Condensor CE1.
DESCRIPTION Oscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency. Ocillatory wave is as following Fig 2-1. VDD-10% VSS+10% Fig 2-1 Sensor(3) Room temperature and Evaporator temperature Sensor Input 070LH,091LH 182LH, 240LH 330 R8 23 O/C SENSOR CN10 R9 12.7kF CC7 103 MICOM 103 CC6 CN9 24 I/C SENSOR R10 12.7KF R7 330 ROOM SENSOR R11 12.7KF R6 330 25 CC5 103 DESCRIPTION Number 24, 25 of Micom is Terminal of A/D convertor Input.
Triac Driving(4) 12V N L1 TLP561 PT1 1 AC 220V 2 L 130µH 3A MICOM T1 SM3JZ47 IC4 KID 65004 38 2 15 R5 SN1 0.1µF 120Ohm TO MOTOR 1K 1/2W DESCRIPTION Number 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is supplied Trigger Signal. Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Time delay part according to Fan Speed. (Ref. Fig 4-1) SN1 is Snubber.
Remote Controller(5) DESCRIPTION Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gotten fid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1. But in Secondary Wave Custom Code is Reversed Face. 9ms 4.5ms 16bit 24bit 8bit 16bit 0.56ms LEADER CODE CUSTOM CODE DATA CODE CHECK SUM 1.69ms 1.12ms bit 0 TAILER 2.
Micom Power Supply(7) 5V VDD 42 CE5 10µF 16V + CC11 104 41 MICOM OSC 8MHz 40 39 19 20 21 VSS 22 CC13 104 DESCRIPTION MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.
Reset(8) MICOM R13 5.6K 1K R12 18 7042P CC9 10.3 IC5 CE4 4.7uF/50V DESCRIPTION Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect Power ON and Voltage less than 4.25V, and then send Reset Signal. Vcc (+5V) 4.
Function Selecting(9) CA3 F3 104Z 41 RA3 4A 103J RA3 R32 1K JS5 R31 1K JS4 MILD/HIGH 40 39 HEAT/COOL R30 1K MICOM 30 model JS3 1K R17 JS2 1K R16 29 14 RA2 6A 103J RA1 27 16 CA2 R36 heat/low 1K R28 1K R25 1K R24 R33 cool/high 1K R23 R37 monitoring 1K R29 28 15 1K R15 JS1 F5 104Z CA1 26 R35 cool/low R34 heat/high DESCRIPTION * When power source is put at fist, Funtion selection input is recognized.
Zero Crossing Detect(11) VCC R3 10K 2 TR1 KRC120M D5 2 1 R27 1K MICOM 31 3 R2 5.6K 1 D6 2 TRANS OUTPUT 1 CC4 103 2 1 DESCRIPTION It defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom. Detail Driving is as following Fig 11-1. R19 is Resistance to limit current.
Stepping Motor Driving(12) 12V CN13 1 IC6 MICOM B+ 2 1 3 Ø1 2 4 Ø2 3 5 4 6 M1 FOR SWING Ø3 Ø4 KID65004 DESCRIPTION There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method. It is driving as following Fig 12-1.
2 REMOTE CONTROLLER ASSMBLY FUNCTIONAL TEST METHOD TEST START No Power supply again Power Supply Is Display at the beginning ON? Select ON/OFF button Yes Is Display at the beginning ON? No Select Mode button Is it normal? No ERROR Select FAN SPEED button Is it normal? Select FAN DIR. button Is it normal? Is display at the begining ON? Select TEMP. Button (▲,▼) Is it normal? No ERROR ( ▲) ▼ No ERROR No ERROR (Whenever you selectted Temp.
Is LCD display OFF? No ERROR Select TIMER ON Button Is it normal No ERROR Select Timer Enter Button TIMER display? No ERROR Select CANCEL Button Is all display OFF? No ERROR Select ON/OFF Button Select OFF (Timer) Button Is it normal? (0.
8.
(2) U2, 4 (KID65004) DARLINGTON ARRAYS 16 OUT 1 15 OUT 2 14 OUT 3 13 OUT 4 12 OUT 5 11 OUT 6 10 OUT 7 9 COMMON FREE WHEELING DIODES KID65004AP COMMON INPUT OUTPUT 10.5KΩ 7.2KΩ 3KΩ IN1 1 IN2 2 IN 3 3 IN 4 4 IN5 5 IN6 6 IN7 7 GND 8 GND (Equivalent Circuit) (Top View) (3) U8 (KIA7805P) : VOLTAGE REGULATOR (5VDC) SCHEMATIC DIAGRAM INPUT 100K 100 100 500 10K 240 200 3.3 K 1 2 3 1.4 K Pin 1. INPUT 2. GROUND 3. OUTPUT OUTPUT 2K 6K 2.7 K 0.3 0.
(5) U9 (KIA7042P) : RESET IC 1 VCC KIA70 42P 3 OUT 2 GND INPUT GROUND OUTPUT OUTLINE 87
9. DISASSEMBLY INSTRUCTIONS 1 INDOOR UNIT ◆DSB-070L/DSB-091L PROCEDURES PHOTOS 1. Stop the operation of the Air conditioner and disconnect the power cord from the wall outlet. Fig 1 2. Removing the Insert Grille and Frame Grille. (Fig 1~2) 1 Draw up the Insert Grille and remove it. 2 Loosen the screw fixed at the Cover Ter-Block. 3 Loosen two screws fixed at the Frame Grille. 4 Remove the Frame Grille. 3. Removing the Control Box. (Fig 3) 1 Remove room and coil thermistors.
◆DSB-071L/DSB-092L PROCEDURES PHOTOS 1. Stop the operation of the Air conditioner and disconnect the power cord from the wall outlet. Fig 1 2. Removing the Insert Grille and Frame Grille. (Fig 1~2) 1 Draw up the Insert Grille and remove it. 2 Loosen the screw fixed at the Cover Ter-Block. 3 Loosen two screws fixed at the Frame Grille. 4 Remove the Frame Grille. 3. Removing the Control Box. (Fig 3) 1 Remove room and coil thermistors. 2 Disconnect the fan motor lead wire from connection at the Control PCB.
◆DSB-121L/DSB-122L PROCEDURES PHOTOS 1. Stop the operation of the Air conditioner and disconnect the power cord from the wall outlet. Fig 1 2. Removing the Insert Grille and Frame Grille. (Fig 1~2) 1 Draw up the Insert Grille and remove it. 2 Loosen two special screws fixed at the Cover Ter-Block. 3 Loosen three screws fixed at the Body. 4 Remove the Frame Grille. 3. Removing the Control Box. (Fig 3) 1 Remove room and coil thermistors.
◆DSB-123L/DSA-123L PROCEDURES PHOTOS 1. Stop the operation of the Air conditioner and disconnect the power cord from the wall outlet. Fig 1 2. Removing the Insert Grille and Frame Grille. (Fig 1~2) 1 Draw up the Insert Grille and remove it. 2 Loosen the screw fixed at the Cover Ter-Block. 3 Loosen four screws fixed at the Frame Grille. 4 Remove the Frame Grille. 3. Removing the Control Box. (Fig 3) 1 Remove room and coil thermistors.
◆DSB-181L/182L/182L-R, DSA-182L/DSA-181L PROCEDURES PHOTOS 1. Stop the operation of the Air conditioner and disconnect the power cord from the wall outlet. 2. Removing the Insert Grille and Frame. 1 Loosen three screws fixed at the the Insert Grille and Frame. (Pull out the frame cap before loosening three screws) (Fig 1) 2 Loosen three screws fixed at the Drain Pan. 3 Remove the Insert Grille and Frame. 3. Removing the Control Box. 1 Disconnect indoor room and coil thermistors.
PROCEDURES PHOTOS 7. Removing the blower. 1 Loosen the screw fixed at the holder bearing. 2 Remove the blower.
◆DSA-183L/183L-R/240L-R/240L, DSB-183L-R/240L-R PROCEDURES PHOTOS 1. Stop the operation of the Air conditioner and disconnect the power cord from the wall outlet. Fig 1 2. Removing the Insert Grille and Frame Grille. (Fig 1~2) 1 Draw up the Insert Grille and remove it. 2 Loosen the screw fixed at the Cover Ter-Block. 3 Loosen two screws at the Frame Grille. 4 Remove the Frame Grille. 3. Removing the Control Box. (Fig 3) 1 Remove room and coil thermistors.
2 OUTDOOR UNIT ◆DSB-070L/071L/DSB-091L/092L/DSB-121L/122L/123L/DSA-123L PROCEDURES PHOTOS 1.Stop the operation of the air conditioner and disconnect the wire from Indoor Unit to Outdoor Unit. 2. Disassemble the case. (Fig 1~2) 1 Remove the Top Panel. (Loosen thirteen screws) 2 Remove the Front Cabinet. (Loosen six screws) 3 Remove the Side Cabinet. (Loosen seven screws) 4 Remove the Guide Support. (Loosen two screws) 3. Removing the Propeller Fan. (Fig 3) 1 Loosen the Nut fixed at the the Propeller Fan.
◆DSB-181L/182L/182L-R/183L-R, DSA-181L/182L/183L-R/DSA-181L PROCEDURES PHOTOS 1.Stop the operation of the air conditioner and dis connect the wire from in door unit to out door unit. 2. Disassemble the case. (Fig 1~2) 1 Remove the Top Panel. 2 Remove the Side Cabinet. 3 Remove the Front Cabinet. Fig 1 3. Removing the Propeller Fan. (Fig 3) 1 Loosen the screw fixed at the motor bracket. 2 Remove the Plain Washer. 3 Remove the Propeller Fan. Fig 2 4. Remove the panel control.
◆DSB-240L-R/DSA-240L-R/240L PROCEDURES PHOTOS 1.Stop the operation of the air conditioner and disconnect the wire from in door unit to out door unit. 2. Disassemble the case. (Fig 1~2) 1 Remove the Top Panel. 2 Remove the Front Cabinet. 3 Remove the Side Cabinet. Fig 1 3. Removing the Propeller Fan. (Fig 3) 1Loosen the screw fixed at the motor bracket. 2Remove the Plain Washer. 3Remove the Propeller Fan. Fig 2 4. Temove the panel control. (Fig 4) 1Disconnect the wire at the control panel.
3 EXPLODED DIAGRAM (Indoor Unit) ◆DSB-070L/DSB-091L 98
◆DSB-070L/DSB-091L PART LIST(INDOOR UNIT) No PART CODE PART NAME 1 3100400301 BODY 2 3108008700 MOTOR IDU 3 3101500400 4 Q'TY SPEC 1 HIPS T2.0 CUSHION MOTOR 2 CR Ø30 3106400400 BEARING PLASTIC ASS’Y 1 5 3100053700 FAN CROSS FLOW ASS’Y 1 Ø90.0xL540 6 7485401012 SET SCREW 1 6S-4x10-E MFZN 7 3103002601 HOLDER MOTOR 1 HIPS T2.0 8 3100053800 EVAPORATOR ASS’Y 1 9 3102501220 EVAP. GUIDE 1 PVC T0.7 L536 10 3100603800 BRACKET PIPE 1 HIPS T2.
◆DSB-071L/DSB-092L 100
◆DSB-071L/DSB-092L PART LIST(INDOOR UNIT) No PART CODE PART NAME Q'TY 1 3100400300 BODY 1 HIPS T2.0 2 3108004700 MOTOR IDU 1 IC-8417DWKF5A 3 3101500400 CUSHION MOTOR 2 CR Ø30 4 3106400400 BEARING PLASTIC ASS’Y 1 5 3100053700 FAN CROSS FLOW ASS’Y 1 Ø90.0xL540 6 7485401012 SET SCREW 1 6S-4x10-E MFZN 7 3103002600 HOLDER MOTOR 1 HIPS T2.0 8 3100053800 EVAPORATOR ASS’Y 1 9 3102501200 EVAP. GUIDE 1 PVC T1.0 L536 10 3100603800 BRACKET PIPE 1 HIPS T2.
◆DSB-121L/DSB-122L 102
◆DSB-121L/122L PART LIST(INDOOR UNIT) No PART CODE PART NAME Q'TY 1 3100400201 BODY 1 ABS or HIPS 2 3108001220 MOTOR IDU 1 220V 50/60Hz 3 3101500400 CUSHION MOTOR 2 CR 4 3106400200 BEARING PLASTIC ASS’Y 1 5 3100014400 FAN CROSS FLOW ASS'Y 1 SAN+G.
No PART CODE 15-8 3102797910 HARNESS 1 I.
◆DSB-123L/DSA-123L 105
◆DSB-123L/DSA-123L PART LIST(INDOOR UNIT) No PART CODE 1 3110400300 BODY 1 HIPS T2.0 (GY171A) 2 3110078100 MOTOR IDU ASSY 1 ASSY 3 3118003500 MOTOR IDU 1 RB13B(220V, 50/60V) 4 3106400400 BEARING PLASTIC ASSY 1 DSB-123L/LH/PH 5 3110046000 FAN CROSS FLOW ASS`Y 1 SAN+G.F 30% ø100xL615 6 3113000400 HOLDER MOTOR L 1 HIPS T2.0 7 7172401211 SPECIAL SCREW 2 TT2 TRS 4*12 MFZN 8 3113000500 HOLDER MOTOR R 1 HIPS T2.
No PART CODE 38 3114302020 CONTROL PCB ASS`Y 1 DSB-123L 39 3116501000 BLADE VERTICAL 3 P.P T1.5 (GY176A) 40 3117600100 FLAP 1 HIPS T2.0 (GY171A) 41 3100700700 BUSHING R 1 42 3112200700 FRAME GRILLE 1 HIPS T2.5 43 3114504200 PLATE LED 1 PC SHEET T0.
◆DSB-181L, DSB-182L/L-R, DSA-181L/182L v x c 108
◆DSB-181L/182L/L-R Parts List (Indoor Unit) No PART CODE PART NAME Q'TY SPEC 1 3100400101 BODY 1 ABS 2 3107600100 FLAP TOP 1 ABS 3 3107600200 FLAP UNDER 1 ABS 4 3106500400 BLADE VER 16 ABS 5 3103000500 HOLDER MOTOR R 1 ABS 6 3103000700 HOLDER BEARING 1 ABS 7 3103000600 HOLDER MOTOR L 1 ABS 8 3106400100 BEARING OILESS 1 9 3101800200 FAN CROSS FLOW 1 Ø100X861L 10 3102400800 GRILLE LATCH 3 POM 11 3108000311 MOTOR ASS’Y 1 IC-9425 DWKC 5C 3102400900 12
No PART CODE PART NAME Q'TY 21 3100000200 FILTER PRE L ASS’Y 1 22 3102900100 HINGE R-A 1 POM 23 3102900300 HINGE L-A 1 POM 24 3100001000 M-PCB ASS’Y 1 25 3107800100 LINK VER CAM 1 26 3104395400 F-PCB ASS’Y 1 27 3108000200 MOTOR STEPPING 2 28BYJ48-V2 28 3108914100 TERMINAL BLOCK 1 JXO-CH-3P 29 3107400300 EVA BRKT L 1 SGCC T1.
◆DSB-183L-R/DSA-183L/183L-R/DSB-240L-R/DSA-240L/240L-R CONTROL BOX ASSY 111
◆DSB-183L-R/DSA-183L/183L-R/DSB-240L-R/DSA-240L/240L-R PART LIST (INDOOR UNIT) No PART CODE PART NAME Q'TY 1 3100400600 BODY 1 2 3108007500 MOTOR FCU 1 IC-9430DWKG7A 3 3101500400 CUSHION MOTOR 2 CR I.D30 (R/W45) 4 3106400200 BEARING PLASTIC ASSY 2 O.D37 .0*I.D6.0 5 3100076400 FAN CROSS FLOW ASSY 1 Ø100XL864 6 7485401012 SET SCREW 1 6S-4*10-E MFZN(BLACK) 7 3103003800 HOLDER MOTOR L/B 1 8 3103003900 HOLDER MOTOR R 1 9 3103004000 HOLDER BEARING 1 ABS T2.
No PART CODE PART NAME Q'TY 32 2150013200 AL FOIL EMI 33 3106902400 CAPACITOR SH.M.B 1 2.
4 EXPLODED DIAGRAM(Outdoor Unit) ◆DSB-070L/071L/DSB-091L/092L/DSB-121L/122L/123L/DSA-123L 30 42 114
◆DSB-070L/071L/DSB-091L/092L/DSB-121L/122L/123L PART LIST(OUTDOOR UNIT) No 1 PART CODE 3100300511 3100300531 PART NAME PAN BASE Q'TY 1 SPEC REMARK SECC T1.2 071L/092L SECC T1.2 123L 071L(DW COMP RBB070A011) 2 3106000900 COMP. BOLT 3 M8XL46.5 092L(DW COMP RBB095A011) 123L(DW COMP. RCB120A001) 3 3102100800 FOOT 2 SECC T1.2 070L/091L/123L 071L (DW COMP RBB070A011) 4 3108134AEO COMP. BOLT 3 EPDM 092L (DW COMP RBB095A011) 123L(DW COMP.
No PART CODE PART NAME Q'TY 16 3102501100 GUIDE SUPPORT 1 SECC T1.2 17 3102402600 GRILLE CONDENSER 1 P.E. 660x525.5xT3.5 18 3100601903 BRACKET MOTOR 1 SBHG1 T1.2 3108008900 19 3118001100 MOTOR ODU 1 3118001300 SPEC YDK-30-6B 071L A9525BD010 092L A9530CD010 123L 20 3101801000 FAN PROPELLER 1 ABS+G.F20% (BLACK) 21 7400208411 WASHER PLAIN 1 PW-2-8 MFZN 22 7392800011 NUT LOCK 1 M8 x P1.25 MFZN 23 3104201900 PANEL CONTROL 1 SBHG1 T0.
◆DSB-181L/182L/182L-R/183L-R, DSA-182L/183L-R/183L/DSA-181L 117
◆DSB-181L/182L/182L-R/183L-R/DSA-183L-R/183L Parts List (Outdoor Unit) No PART CODE PART NAME Q'TY SPEC 1 3102402100 GRILLE COND 1 PE 2 3114200500 PANEL TOP 1 SECC T1.0 3 3110800200 CABINET 1 SECC T1.0 4 3101800100 FAN 1 ABS + G/F 5 3102400710 GRILLE DISCHARGE 1 PP 6 3110800300 CABINET 1 SECC T1.0 PAN BASE 1 SECC T1.2 3118100200 7 DSB-182L/183L 3118100220 8 3110600200 BRACKET MOTOR 1 SGCC T1.2 9 3114200600 PANEL CONTROL 1 SGCC T0.
No PART CODE PART NAME Q'TY SPEC 3110025700 20 REMARK DSB-182L/L-R/DSB-183L-R PIPE FILTER ASS'Y 1 3110030700 DSA-183L-R 3107140100 SHW-33TC4-U DSB-181L/182L 3100068010 AWG5524EXC DSB-182L-R/DSB-183L-R 3100068110 AWG5519EXN DSA-183L-R 3100091700 RCA180T001 DSA-183L 21 COMPRESSOR 1 22 3105400200 SERVICE VALVE-LIQ 1 C3771, 1/4" 23 3105400100 SERVIC VALVE-GAS 1 C3771, 1/2" 25 3118900210 TERMINAL BLOCK 1 JXO-CH-2P 26 3118900210 FOOT CUSHION 4 NR 3 M8xL70 DSB-182L/1
◆DSB-240L-R/DSA-240L-R/240L POWER CODE 25 23 15-4 15-5 15-1 15-2 15 15-3 6 20 19 14 17 18 16 8 9 2 1 5 4 3 2 22 7 13 12 11 10 21 24 120
◆DSB-240L-R/DSA-240L-R/240L PART LIST (OUT DOOR UNIT) No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15-1 15-2 15-3 15-4 15-5 16 17 18 19 20 21 22 23 24 PART CODE 3100041750 310003118P 310P30281A 3100068201 3100068300 3117147300 7400208411 7392801211 3106800500 3100078020 3100089303 311009MS00 3102402100 3100041100 3100041200 3100041201 3105401800 3105401200 3106002300 3100031702 3100086500 3104201601 3108914100 3118900210 3101202600 3101202000 3109504830 3109504820 3116908600 3101203300 3105300400 3108009900 3108
5 CONTROL BOX ASSEMBLY ◆DSB-070L/071L/091L/092L 3 8 7 4 6 2 9 1 5 122
◆DSB-070L/DSB-091L No PART CODE PART NAME Q'TY 1 3100054400 CONTROL PCB ASS’Y 1 2 3108914100 TERMINAL BLOCK 1 JXO-CH-3P 3 3106900300 CAPACITOR SH.M.B 1 1.
◆DSB-121L/DSB-122L 8 7 H3 H1 H2 6 2 S H3 1 4 3 124
◆DSB-121L/DSB-122L No PART CODE PART NAME Q'TY 1 3100503101 CONTROL BOX 1 P.P+G.F 20% 2 3100054400 CONTROL PCB ASS'Y 1 FR-1 3 3108054200 LED PCB ASS'Y 1 FR-1 4 3103400300 KNOB RESET SWITCH 1 ABS 6 3108914100 TERMINAL BLOCK 1 JXO-CH-3P 7 5EPV050100 TRANS FORMER 1 DWA220A-50/60Hz 8 3106900300 CAPACITOR SH.M.B 1 1.
◆DSB-123L/DSA-123L 126
◆DSB-123L/DSA-123L No PART CODE 1 3110504000 PART NAME Q'TY CONTROL BOX 1 SPEC HIPS T2.
◆DSB-182L/182L-R/DSA-181L/182L 17 128
◆DSB-182L/182L-R /DSA-181L/182L NO PART CODE PART NAME Q'TY 1 3100506900 CONTROL BOX 1 2 3104300720 CONTROL PCB ASS’Y 1 3 3104300212 POWER PCB ASS’Y 1 4 3104300301 SWITCH PCB ASS’Y 1 5 3104300401 LED PCB ASS’Y 1 7 3108000200 MOTOR STEPPING 2 28BYJ48-V2 8 3108914100 TERMINAL BLOCK 1 JXO-CH-3P 9 5EPV633110 TRANSFORMER 1 DWA220V 50Hz 10 3106900200 CAPACITOR I.D.M 1 SH.M.B 1.
◆DSB-183L-R/DSA-183L-R/183L/DSB-240L-R/DSA-240L-R/240L 3 12 7 4 6 5 10 8 11 1 130
◆DSB-183L-R/DSA-183L-R/183L/DSB-240L-R/DSA-240L-R/240L No PART CODE PART NAME Q'TY 1 3100094250 CONTROL PCB ASS’Y 1 3 3106902400 CAPACITOR SH.M.
DAEWOO ELECTRONICS CO., LTD 686, AHYEON-DONG MAPOGU, SEOUL, KOREA. C.P.O. BOX 8003 SEOUL KOREA TELEX: DWELEC K28177-8 CABLE:"DAEWOOELEC" FAX: +82-2-364-5588 TEL: +82-2-360-7114, 8114 http://www.dwe.co.kr S/M NO.