Service manual

22
13. HOW TO DISASSEMBLE
1 Before service of 1. Stop the unit, remove the power cord from the receptacles.
any part. 2. Move the unit to the safe location for the suitable work.
2 Assy Fan Motor 1. Remove Front Grille
- Fan Motor - Remove Filter Pre.
- Propeller Fan - Remove screw(2 point) in Front Grille.
- Blower Fan 2. Remove Cabinet from the unit.
- Remove screws (4 point) from the units sides.
3. Remove Holder Scroll.
4. Remove Scroll upper
5. Remove Assy Control Box
- Remove screws (4 point).
- Remove wires in the each components.
6. Remove wires in the Panel Housing.
7. Remove screws (4 point) from Assy Fan Motors sides.
- Assy Fan Motor is assembly of Fan Motor, Propeller and Blower Fan, Orifice
and Panel Housing.
8. Lift the Assy Fan Motor from the unit.
- Remove screws (7 point)
9. Remove Clip Fan (2 point) from the shaft of Fan Motor.
10. Remove Propeller Fan from the shaft of Fan Motor.
11. Remove Blower Fan from the shaft of Fan Motor.
12. Remove Fan Motor from Panel Housing.
- Remove screws (4 point).
3 Assy Control Box 1. Same as the procedure 1 to 5 in the Item 2.
-
Rotary Switch (selector)
- Auto Louver Switch.
- Thermostat
- Capacitor
- Power Cord
Please refer to the chapter 14 (Exploded diagram and parts list).
DWA-181CH/DWA-240CH-R/DWB-180CH-R/DWB-240CH-R