Service manual

36
4) Motor conduction time for a drying cycle
Textile pulling Drying Cooling Wrinkle free Cycle time (min) Heater off/on
Low temperature 10/5 15/5 10/10 10/50 110 70/60
Low temperature (sports shoes)
10/5 2/30 2/30 X 36 70/60
Ironing 10/5 15/5 10/10 10/50 60 105/95
Standard 10/5 15/5 10/10 10/50 150 105/95
Strong 10/5 15/5 10/10 10/50 200 105/95
1You can select one of 1 hr/ 90 minutes/2 hours.
2If a sports shoes course is selected and the time is selected, the motor conduction time is determined by a sports
shoes course.
3Except for a sports shoes course, if the time is selected then the motor conduction time is determined by the
standard course.
5) Drying valve operation
120 seconds after drying starts, it continues until drying is completed) 30 sec on/5 sec off.
6) Cooling operation
1Its purpose is to lower the temperature of the tank after drying is completed) The fan motor and the main motor
operate at the same time.
2If the drum internal temperature is below 50 degrees, cooling is terminated.
3The total duration of cooling is five minutes) If the internal temperature can’t be lowered, then the time is not
reduced anymore.
7) Drying heater operation
1The drying heater continues to operate until drying is completed) 105 deg off/95 deg on.
270 deg off/60 deg on for low temperature drying) 50 deg off/40 deg on for a sports shoes course.
3For air washing, 80 deg off/70 deg on.
8) Wrinkle-free operation
1It lasts for 30 minutes after drying is completed.
2During wrinkle-free operation, the motor only operates) The fan motor and the drying v/v do not operate.
3If you press the pause button during wrinkle-free operation, the motor is stopped and the door is opened.
2-6 Steam operation
1) Steam water supply
1In steam operation, the water is supplied twice for one minute each.
2Constant temperature control is done until reaching the initial phase steam water supply point.
3If the laundry is soaked in the water and the water level drops, then water is supplied again) To reduce the number
of water supplies, the water supply level is set to 10mm higher than the steam point (1.5 phase).
4Depending on load sensing or the course setting value, the water supply level is chosen to be low or extra low.
5If powder DET is injected, then the main washing valve is opened and closed five times.
6If liquid DET is selected the liquid DET stirring motor operates for 30 sec for low levels and for 20 sec for extra
low levels) At this time, the main washing valve operates too.
7When liquid DET is fully injected, then washing water supply including constant temperature control begins.
8If powder DET is selected or liquid DET injection completion is memorized, then liquid DET injection process is
skipped.
9If the water supply is completed, to clean the DET box, the main washing valve and the reserved washing valve
operate for 10 seconds.